Transmission lines are affected by Aeolian vibration, which causes strands to break and eventually causes an entire line to break. In this paper, a method for monitoring strand breaking based on modal identification is proposed. First, the natural frequency variation of a conductor caused by strand breakage is analyzed, and a modal experiment of the LGJ-95/15 conductor is conducted. The measurement results show that the natural frequencies of the conductor decrease with an increasing number of broken strands. Next, a monitoring system incorporating a fiber Bragg grating (FBG)-based accelerometer is designed in detail. The FBG sensor is mounted on the conductor to measure the vibration signal. A wind speed sensor is used to measure the wind speed signal and is installed on the tower. An analyzer is also installed on the tower to calculate the natural frequencies, and the data are sent to the monitoring center via 3G. Finally, a monitoring system is tested on a 110 kV experimental transmission line, and the short-time Fourier transform (STFT) method and stochastic subspace identification (SSI) method are used to identify the natural frequencies of the conductor vibration. The experimental results show that SSI analysis provides a higher precision than does STFT and can extract the natural frequency under various wind speeds as an effective basis for discriminating between broken strands.
20 May 2024 in IEEE Transactions on Instrumentation and Measurement
To address the low accuracy and moderate speed of traditional foreign object detection in transmission line image inspection, the FusionNet is proposed based foreign object detection algorithm in severe weather. First, the FB module(Fusion Block) is proposed in this algorithm, combined with the CA attention(Coordinate Attention) mechanism and the Hardswish activation function, so that the network can increase the learning of the location information based on the attention on the overall classification information, and reduce the network parameters. Then, based on FasterNet, the FSB module (Fusion Speed Block)is proposed to extract the space more efficiently. In addition, the FMB module(Fusion Memory Block) is proposed, which makes full use of the accumulated information in the past to extract more accurate and abundant features. Finally, the utilization of EfficiCIoU as a loss function serves to expedite model convergence and enhance detection precision. Experimental results show that on the dataset in this paper, the improved algorithm mAP@0.5 reaches 98.27%, the model parameters are reduced by 130.42M compared with the Faster-RCNN model, and the accuracy is improved by 19.62% and 4.63% compared with SSD and YOLOv7 models, respectively. The performance on the China Power Line Insulator Dataset (CPLID) is also excellent, reaching 99.17% mAP@0.5, an improvement of 1.85% compared with the baseline model. Compared to the existing models, the FusionNet model is smaller in size and has higher detection accuracy. It can accurately detect targets in inclement weather and perform the task of foreign body detection in transmission lines.
The capacitive method is considered to be a suitable icing-detection technology, but the lack of fundamental parameters restricts the development of icing-detection sensors. In this paper, an artificial icing laboratory, a capacitive sensor, and some simulation conductors have been designed for obtaining the artificial icing samples. Subsequently, the same characteristic values of artificial icing have been measured by an LCR device, under a selected frequency. This research found that the value of the icing dielectric constant closely correlated with its density, internal sublayer, and the test temperature. Finally, a fitting formula has been presented for calculating the relative dielectric constant, which may provide some important reference value for the design of icing-detection sensors.
1 April 2020 in IEEE Transactions on Instrumentation and Measurement
Icicles generated on the insulator sheds will constantly shorten the insulating gap distance between adjacent sheds as growth, thereby inducing significant decrease in electrical insulation of the insulators, icicle bridging even threatening the operating security of power systems. In order to evaluate whether the ice-covered insulator needs to de-icing or the icicles bring in potential dangers, a study on detection and condition assessment of icicle bridging for ice-covered suspension glass insulator by image analysis is proposed in this paper. First, the initial icicles regions are obtained by the Local Variation threshold segmentation algorithm based on the optimized texture energy image. Second, the insulator sheds are segmented and extracted based on the normalized color difference operator, and then the complete icicles regions are obtained through the image difference and post-processing. Finally, the icicle length is calculated by finding its smallest axis-parallel enclosing rectangle, and two adjacent insulator sheds spacing which is calculated by ellipse fitting is used as bridging threshold, so the condition of icicle bridging can be defined as the Safe, Observation and Danger. The results demonstrate the icicles can be effectively enhanced and accurately segmented by the presented method in this paper, and the icicle bridging condition of ice-covered insulator can be assessed with average detection accuracy of 92.2% and average time consumption of 3.910s, by which the safe operation of ice-covered insulator can be monitored and guaranteed.
Icicle will cause serious distortion of insulator electric field, weaken its voltage strength, and easily cause insulator flashover. Previous studies have shown that the longer the length of icicles on insulator, the greater the possibility of electric flashover. Then, it is of great theoretical significance and practical value to study the image identification technology of icicle length of iced insulators. Firstly, the growth mechanism and structural characteristics of insulator icicles are discussed in this paper, and the image acquisition method of iced insulator is discussed. Secondly, the methods of saliency detection and color feature analysis are used to extract the region of icicle and insulator sheds respectively, then, the icicle structure on insulator is obtained by the difference calculation of above two images. Meanwhile, the pixel curve of the iced insulator image is processed by Fourier transform, and the reference size of insulators icicle is obtained by calculating the length of the shed spacing. Finally, a practical case about iced insulators in substations is analyzed in detail, which proves the effectiveness of the method proposed in this paper.
9 May 2024 in Journal of Real-Time Image Processing