Peri-implantitis is a common implant-supported prosthesis complication, and marginal bone loss affects the stress distribution in implant systems. This three-dimensional finite element analysis study investigated how bone loss affects the implant assembly; in particular, models including two implant systems with different connection systems (external or internal hexagon), abutment materials (titanium or zirconia), and bone loss levels (0, 1.5, 3, or 5 mm) were created. We observed that the maximum von Mises stress distinctly increased in the groups with bone loss over 1.5 mm compared to the group without bone loss, regardless of the connection system or abutment material used. Moreover, the screw stress patterns with bone loss progression were determined more by the connection systems than by the abutment materials, and the magnitude of the stress on the fixture was affected by the connection systems with a similar pattern. The highest stress on the screw with the external hexagon connection system increased over 25% when bone loss increased from 3 to 5 mm, exceeding the yield strength of the titanium alloy (Ti–6Al–4V) when 5 mm bone loss exists; clinically, this situation may result in screw loosening or fracture. The highest stress on the fixture, exceeding the yield strength of pure titanium, was noted with the internal hexagon connection system and 1.5 mm bone loss. Titanium and zirconia abutments—both of which are clinically durable—presented similar screw and fixture stress patterns. Therefore, clinicians should pay more attention to maintaining the peri-implant bone to achieve the long-term stability of the implant-supported prosthesis.
The type of implant-abutment connection is one of the factors influencing the distribution of occlusal forces. This study aims to investigate the biomechanical performance of the mandibular all-on-4 treatment with different implant–abutment connections. Two connection types with 30° abutments and 18-mm implant fixtures were chosen for the posterior implants of the all-on-4 assembly. For the external hexagon connection (EHC) group, the implants with 4 mm in diameter were used. For the internal hexagon connection (IHC) group, we selected implants with 4.3 mm in diameter. A vertical force of 190 N was applied to the cantilever region. The FEA results indicated that the most stressed region in the two groups was prosthetic screws, followed by multi-unit abutments (MUAs). The lowest values of von Mises stress were both observed on the bone. The peak stress value of the implant screw and implant fixture in the EHC group were 37.75% and 33.03% lower than the IHC group, respectively. For stress distribution patterns, the load force tended to be concentrated at locations where components were interconnected. The EHC and IHC are clinically durable under the tested loading conditions, but the prosthetic screws and MUAs can be the weak point on the posterior implant within the mandibular all-on-four assembly. The peak stress values of implant screw and implant fixture in the EHC groups were lower than the IHC group.
Residual alveolar ridge resorption often occurs after tooth extraction, which causes issues requiring further prothesis rehabilitation. A treatment concept referred to as all-on-four, involving fixed dentures supported with four implants, was recently developed. The current study aimed to determine the effect of changing bone atrophy and implant length in all-on-four treatments on stress and strain in the surrounding bone of the implant. A three-dimensional finite element method was used in this research. The stress analysis was conducted with von Mises stress values. Two types of synthetic jawbone models with mild and moderate atrophy were used. Furthermore, two different implant lengths with a similar implant design and diameter were selected, and they were classified into eight models. Then, the bone model was assessed via a computed tomography (CT) scan and was transformed into a virtual model in Geomagic and SolidWorks with implant rebuilding. After modifying bone atrophy, the von Mises stresses in the surrounding bone of the implant were as follows: mild type 2 < mild type 3 < moderate type 3 < moderate type 4. The bone quantity change rate increased more than when bone conditions were limited. Compared with changes in implant lengths, the stresses in the peri-implant surrounding bone were generally higher in the 9 mm implant length group than in the 11.5 mm group. However, the results did not significantly differ. In conclusion, the von Mises stress and strain increased in the models with moderate atrophy and low-density trabecular bone. Hence, bone atrophy and its presurgical diagnosis in long-term implant prognosis are crucial.
Three groups of zirconia abutments (n = 5) consisting of different connection designs or manufacturers were investigated (All-Zr, ASC-Zr, and AM-Zr groups). All-electric dynamic test instruments were used to place static loading on a specimen with a crosshead speed set at 1 mm/min. A Kruskal–Wallis test and a post hoc Mann–Whitney U test were used for statistical evaluation. The mean fracture resistance was 252.37 ± 82.79 N for the All-Zr group, 384.62 ± 45.24 N for ASC-Zr group, and 361.83 ± 90.31 N for the AM-Zr group. The difference of fracture resistance between the three groups was marginally significant (Kruskal–Wallis test, p = 0.054), with the ASC zirconia abutment tending to have higher fracture resistance than the full zirconia abutment. The modes of failure among the three types of abutments are different. The All-Zr group showed an oblique fracture line starting from the buccal aspect at the region of the implant platform. While the ASC-Zr and AM-Zr groups showed a relatively horizontal fracture line with a greater distance from the implant platform. The titanium inserts cannot significantly improve the fracture resistance of the zirconia abutment. However, they may alter the modes of failure, allowing buccal fracture surfaces of the zirconia abutments to be placed away from the implant platform, thereby protecting the implant–abutment connection.
This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two parts. The first part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5), a 15° access channel with a specially designed zirconia crown (sASC-15) (n = 5), and a 25° access channel with a specially designed zirconia crown (sASC-25) (n = 5). The reverse torque value (RTV) was measured at 0° for each specimen. The second part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5); a 15° access channel with a zirconia crown (ASC-15) (n = 5), and a 25° access channel with a zirconia crown (ASC-25) (n = 5). The manufacturer’s recommended torque was applied to each specimen, and baseline RTV was measured before cyclic loading. Each ASC implant assembly was cyclically loaded at 0 to 40 N with 1 million cycles at 10 Hz. RTV was measured after cyclic loading. Kruskal–Wallis test and Jonckheere–Terpstra test were used for statistical analysis. All specimens were examined under a digital microscope and scanning electron microscope (SEM) to observe the wear of the screw head before and after the whole experiment. A significant difference in the different percentages of straight RTV (sRTV) between the three groups was found (p = 0.027). The angle of ASC to the different percentages of sRTV showed a significant linear trend (p = 0.003). No significant differences were found in RTV difference after cyclic loading among the ASC-0, ASC-15, and ASC-25 groups (p = 0.212). The ASC-25 group had the most serious degree of wear based on a digital microscope and SEM examination. The ASC angle will affect the actual preload acting on a screw: the larger the ASC angle, the smaller the preload. The performance of the angled ASC groups in RTV difference was comparable to that of 0° ASC after cyclic loading.
The geometry of implants plays a crucial role in the success of All-on-Four treatments for the lower jaw. This study builds upon prior research by evaluating the biomechanical performance of implant-supported prostheses in full-arch fixed dental restorations, specifically focusing on different implant lengths and connection types in cases of mild atrophic resorption of the mandible. Four groups were analyzed using finite element analysis (FEA): We utilized 13 or 18 mm posterior 17-degree tilting implants, each paired with two kinds of abutment connections. The external hexagon connection (EHC) group utilized 4 mm diameter implants, while the internal hexagon connection (IHC) group employed 4.3 mm diameter implants. A vertical force was applied to the cantilever region located at the distal side of the posterior implant. The maximum stress regions were observed in prosthetic screws and multi-unit abutments (MUAs) across all groups, with the lowest von Mises stress values noted in the bone. Stress peaks for implant screws and fixtures in the 13 mm group were 19.98% and 11.42% lower, respectively, compared to the IHC group. Similarly, in the 18 mm group, stress peaks were reduced by 33.16% and 39.70% for the EHC group compared to the IHC group. The stress levels on all components remained below the ultimate strength of the titanium alloy. For the same implant lengths, the stress in the prosthetic screw, MUAs, implant screw, and implant fixture positions was lower in the EHC group. When implant length was increased, a decrease in stress levels was observed in the implant screw and fixture of the EHC group and only in the implant screw of the IHC group. However, an increase in stress was noted in the prosthetic screw and MUAs for both groups.