Fourier Dzar Eljabbar Latief

Dr. Fourier Dzar Eljabbar Latief

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2021 in Journal of Petroleum Science and Engineering
Verified
Journal Article
Closed access
MMMuhammad Bisri Mustofa
Muhammad Bisri Mustofa
UFUmar Fauzi
Umar Fauzi
FLFourier Dzar Eljabbar Latief
Fourier Dzar Eljabbar Latief
WWWarsa Warsa
Warsa Warsa

27 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KSKrisnadi Setiawan
Krisnadi Setiawan
RPRisti Saptarini Primarti
Risti Saptarini Primarti
SSSuhardjo Sitam
Suhardjo Sitam
WSWawan Suridwan
Wawan Suridwan
KUKosterman Usri
Kosterman Usri
FLFourier Dzar Eljabbar Latief
Fourier Dzar Eljabbar Latief
Micro-computed tomography (micro-CT) is an invaluable tool for the evaluation of dental implant success, whereby the assessment of bone microstructure is conducted. This review examines the role of micro-CT in evaluating bone microstructure in dental implants. A review of the current literature reveals that micro-CT enables the accurate measurement of bone volume, trabecular morphology, and connectivity density, all of which play a crucial role in implant stability. The high-resolution three-dimensional visualization capabilities of micro-CT are also beneficial for the analysis of osseointegration and the evaluation of bone augmentation biomaterials. Despite the existence of challenges such as imaging artifacts and limitations in in vivo applications, advancements in sub-micron resolution and artificial intelligence integration offer promise for improving diagnostic capabilities. Micro-CT provides valuable insights into bone microarchitecture and osseointegration dynamics, which have the potential to enhance pre-operative planning and clinical outcomes in dental implantology. Future research should prioritize the standardization of micro-CT analysis protocols and the exploration of direct clinical applications of this technology.

30 December 2017 in Spektra: Jurnal Fisika dan Aplikasinya
Verified
Journal Article
Open access
PDF file
UFUlpa Zein Fawziah
Ulpa Zein Fawziah
ARAceng Kurnia Rochmatulloh
Aceng Kurnia Rochmatulloh
RSRizki Fahmi Sumaryono
Rizki Fahmi Sumaryono
SFSelly - Feranie
Selly - Feranie
FLFourier Dzar Eljabbar Latief
Fourier Dzar Eljabbar Latief
Abstrak Kompleksitas struktur pori terhubung pada sampel digital medium berpori 2D telah dianalisis menggunakan parameter tortuositas. Jalur pori terhubung dilacak dengan menggunakan Simple Neurite Tracer. Metode pelacakan dan perhitungan tortuositas tersebut diujikan pada lima model sederhana yang menunjukan perbedaan tingkat kompleksitas yang signifikan. Metode analisis kompleksitas tersebut kemudian diterapkan pada sampel medium berpori berupa citra digital batuan berukuran 560 × 393 piksel, dan tanah berukuran 560 × 475 piksel. Citra digital sampel tanah dan batuan yang dianalisis berupa irisan 2D pada bidang z-y (sagittal) yang diambil dari sampel 3D hasil pemindaian menggunakan -CT Scanner SkyScan 1173. Pelacakan jalur pori terhubung pada sampel model maupun sampel digital 2D batuan dan tanah yang menggunakan Simple Neurite Tracer menghasilkan koordinat jalur pori terhubung yang kemudian digunakan untuk menghitung nilai tortuositas. Tortuositas dihitung dengan menggunakan definisi rasio antara jumlah total sudut keberlikuan jalur terhadap jarak antara dua sisi sampel yang saling berhadapan. Untuk 5 sampel model yang menunjukkan kompleksitas yang berbeda, diperoleh bahwa semakin kompleks struktur pori tersebut, maka semakin besar nilai tortuositasnya. Untuk analisis pada sampel digital batuan, nilai tortuositasnya yaitu 0,0392 sedangkan pada sampel tanah didapat nilai tortuositas sebesar 0,0431. Kata-kata kunci: simple neurite tracer, tortuositas, kompleksitas, medium berpori Abstract The complexity of the connected pore structure of 2D porous digital media samples has been analyzed using tortuosity parameter. Connected pore was traced using the Simple Neurite Tracer. The tracing method and the tortuosity calculation were tested on five simple models showing significant differences in complexity levels. The complexity analysis method was then applied on digital image of a rock sample with the size of 560 × 393 pixels, and a soil sample with the size of 560 × 475 pixels. Digital images of the rock and soil samples were analyzed on the 2D slices in the zy (sagittal) plane which were obtained from the scanned 3D samples using the µ-CT SkyScan 1173 Scanner. Connected pore tracing for both the 2D models as well as the rock and soil samples was done using the Simple Neurite Tracer which produce the coordinate of the connected pore path which is then used to calculate the value of tortuosity. Tortuosity is calculated by using the definition of the ratio between the sum of the curvaceous angles of the connected pore path to the distance between two facing sides of the sample. For 5 sample models with distinctive complexity, it was found that the more complex the pore structure, the greater the tortuosity value. For analysis on digital samples of rocks, the tortuosity is 0.0392 whereas in the soil sample, the tortuosity is 0.0431. Keywords: simple neurite tracer, tortuosity, complexity, porous medium.

31 July 2022 in Padjadjaran Journal of Dentistry
Verified
Journal Article
Open access
PDF file
AAAya Amida
Aya Amida
DADudi Aripin
Dudi Aripin
AHAyu Trisna Hayati
Ayu Trisna Hayati
FLFourier Dzar Eljabbar Latief
Fourier Dzar Eljabbar Latief
NDNina Djustiana
Nina Djustiana
SWSunardhi Widyaputra
Sunardhi Widyaputra
  Introduction: Root canal filling is an important part of root canal treatment that aimed to seal the root canal system, to prevent bacterial penetration and their toxins into periradicular tissues and to provide favourable environment for periapical healing. Thermoplasticized technique were developed to produce filling with homogenous mass, to achieve optimal sealing ability and to increase the quality of root canal filling. The aim of this study is to analyzed differences of Micro-Computed Tomography (Micro-CT) evaluation of the obturation sealing capability between thermoplastic carrier-based condensing techniques and lateral heat condensation techniques. Methods: This study was conducted under an in-vitro quasi experimental methode to 36 specimens of maxillaris centralis incisivus which were divided to 3 groups, (A) thermoplasticized carrier-based technique (GuttaCore System), (B) warm lateral condensation technique (heat carrier SystemB), (C) cold lateral condensation as control group. Sealing ability is evaluated based on the measurement results of volume percentages of filling material and sealer, volume of void, and surface density, that which was calculated from the 3D volumetric image of Micro-CT device. Data were statistically analysed using Analisis of Variance (ANOVA) and t-test. Result: The result showed significant difference of percentage filling material and sealer volume in apical third (p0.05). Conclusion: Thermoplastized carrier-based technique is not better than warm lateral technique. Keywords: sealing ability; root canal filling; thermoplasticized carrier-based technique; warm lateral technique.

1 September 2026 in Physics Education
Verified
Journal Article
Closed access
PDF file
SNSekar Kinanti Nugraheni
Sekar Kinanti Nugraheni
FLFourier Dzar Eljabbar Latief
Fourier Dzar Eljabbar Latief
The teaching of blackbody radiation in secondary physics is often challenging due to its abstract nature and limited availability of appropriate instructional resources. This study aims to implement an integrated learning design incorporating a thermal camera-based apparatus powered by the MLX90640, virtual simulations, and project-based learning (PjBL) to support the teaching of blackbody radiation in secondary education. The study employed a research-and-development approach using the 4D model (define, design, develop, and disseminate). The developed materials were validated by experts and implemented in two 12th-grade classes. The results indicate that the learning apparatus and module are highly feasible. Throughout the PjBL, students mapped land surface temperature using Google Earth Engine and presented their findings as posters, thereby connecting abstract physics concepts with real-world environmental data. In addition, students reported positive perceptions regarding environmental awareness, engagement, and collaboration. This study illustrates how science, technology, engineering, and mathematics and education for sustainable development can be integrated into physics instruction through thermal camera demonstrations, simulation, and real-world environmental data analysis. The proposed learning design offers practical references for teachers seeking to implement technology-enhanced and sustainability-oriented instruction in secondary physics education.

1 November 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
SFSelly - Feranie
Selly - Feranie
DSD Sasmita
D Sasmita
FLFourier Dzar Eljabbar Latief
Fourier Dzar Eljabbar Latief
Box counting fractal dimension has been investigated as 3D Fracture parameters. Geothermal rock fractured and 3D fracture models are characterized its 3D fracture characteristics i.e. aperture, density and intensity. The investigation 3D Fractal dimension as aperture parameter, we use the rock samples and 3D Fracture models that have nearly the same intensity. We found that fractal dimension of 3D fracture has a strongly positive correlation with aperture both for 3D fracture in rock fractured samples and 3D fracture models. Based on this result we conclude that 3D fractal dimension of fracture can be used as parameter of fractures aperture and density. Meanwhile for fractal dimension of 3D fracture as intensity parameter, we use the rock samples and 3D Fracture models that have nearly the same aperture and density. We found that there’s no significant pattern of 3D fractal dimension on fracture intensity of rock samples. For further investigation we generate 3D fracture models. We found that the relation between 3D fractal dimension and 3D fracture intensity is very weak negative correlation. Based on this result, we are unable to conclude that the 3D fractal dimension of fracture can be used as parameter of fractures intensity.