Xiaoyu Qiu

Mr. Xiaoyu Qiu

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2026 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
FLFengzhang Luo
Fengzhang Luo
XQXiaoyu Qiu
Xiaoyu Qiu
SWShengyuan Wang
Shengyuan Wang
ZXZhengyang Xu
Zhengyang Xu

21 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
ZWZhe Wang
Zhe Wang
JDJiali Duan
Jiali Duan
Fengzhang LuoFengzhang Luo
Fengzhang Luo
XQXiaoyu Qiu
Xiaoyu Qiu
Accurate load forecasting is crucial for the safe, stable, and economical operation of integrated energy systems. However, directly applying single models to predict coupled cooling, heating, and electric loads under complex influencing factors often yields unsatisfactory results. This paper proposes a collaborative load forecasting method based on feature extraction and deep learning. First, the complete ensemble empirical mode decomposition with adaptive noise algorithm decomposes load data, and a dynamic time warping-based k-medoids clustering algorithm reconstructs subsequences aligned with system load components. Second, a correlation analysis identifies the key influencing factors for model input. Then, a multi-task parallel learning framework combining a regression convolutional neural network and long short-term memory networks is developed to predict reconstructed subsequences. Case studies demonstrate that the proposed model achieves mean absolute percentage errors (MAPE) of 2.24%, 2.75%, and 1.69% for electricity, cooling, and heating loads on summer workdays, with mean accuracy (MA) values of 97.76%, 97.25%, and 98.31%, respectively. For winter workdays, the MAPE values are 2.92%, 1.66%, and 2.87%, with MA values of 97.08%, 98.34%, and 97.13%. Compared to traditional single-task models, the weighted mean accuracy (WMA) improves by 2.01% and 2.33% in summer and winter, respectively, validating its superiority. This method provides a high-precision tool for the planning and operation of integrated energy systems.

14 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZWZhe Wang
Zhe Wang
ZZZhang Zhang
Zhang Zhang
Fengzhang LuoFengzhang Luo
Fengzhang Luo
XQXiaoyu Qiu
Xiaoyu Qiu
XZXuefei Zhang
Xuefei Zhang
JDJiali Duan
Jiali Duan
With the continuous penetration of flexible resources, the distribution network is gradually forming a two-way interactive supply and demand relationship with the transmission network and users. The deployment of soft open point (SOP) and energy storage represents a crucial strategy for voltage regulation and power flow control in distribution networks. This article puts forth a methodology for optimizing the configuration of SOP and energy storage based on the characteristics of the snowflake-shaped grid and sensitivity analysis. Firstly, the location of the SOP is determined based on the characteristics of the interconnection nodes between snowflake websites. Secondly, the voltage sensitivity analysis is employed to identify nodes that have a significant impact on the system voltage distribution, thereby enabling the selection of an optimal energy storage site. Subsequently, a multi-objective optimization configuration model for SOP and energy storage is established, taking into account the economic efficiency and load balancing of the power grid. Finally, the method is verified using a snowflake-shaped grid in Tianjin. In comparison with the plan that solely considers the economic aspects of the power grid, the method proposed in this article can reduce the degree of load balancing by 50.93% while simultaneously increasing the annual comprehensive cost by only 24.35%.

12 September 2025 in Energies
Verified
Journal Article
Open access
PDF file
ZSZhou Shu
Zhou Shu
QWQingwei Wang
Qingwei Wang
Fengzhang LuoFengzhang Luo
Fengzhang Luo
XQXiaoyu Qiu
Xiaoyu Qiu
The large-scale integration of new power loads, such as electric vehicles and energy storage devices, has led to challenges including insufficient regulation capacity and low resource coordination efficiency in low-voltage distribution transformer areas. To address these issues, this paper proposes an optimal configuration model for flexible interconnected distribution transformer areas based on load aggregation. First, a flexible interconnection architecture is constructed using multi-port power electronic conversion devices, enabling mutual power support and voltage stabilization between adjacent areas. Second, a load aggregator scheduling model is established to quantitatively assess the dispatchable potential of electric vehicle charging loads. On this basis, a multi-objective optimization configuration model is formulated with the objectives of minimizing the comprehensive cost of the system and minimizing the average peak-valley difference of substation transformer loads. Case study results demonstrate that the proposed model significantly improves both economic efficiency and operational reliability. Compared to the traditional independent operation mode, the coordinated optimization scheme reduces the comprehensive system cost by 29.6% and narrows the average load peak-valley difference by 50.8%. These findings verify the synergistic effectiveness of flexible interconnection and load aggregation technologies in enhancing equipment utilization, reducing distribution losses, and improving power supply resilience.