Aaron Hadley

Dr. Aaron Hadley

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2022 in SLEEP
Verified
Journal Article
Closed access
PDF file
Michael GrandnerMichael Grandner
Michael Grandner
ZBZohar Bromberg
Zohar Bromberg
AHAaron Hadley
Aaron Hadley
ZMZoe Morrell
Zoe Morrell
AGArnulf Graf
Arnulf Graf
DFDustin Freckleton
Dustin Freckleton
Study Objectives: Wearable sleep technology has rapidly expanded across the consumer market due to advances in technology and increased interest in personalized sleep assessment to improve health and mental performance. We tested the performance of a novel device, the Happy Ring, alongside other commercial wearables (Actiwatch 2, Fitbit Charge 4, Whoop 3.0, Oura Ring V2), against in-lab polysomnography (PSG) and at-home electroencephalography (EEG)-derived sleep monitoring device, the Dreem 2 Headband. Methods: Thirty-six healthy adults with no diagnosed sleep disorders and no recent use of medications or substances known to affect sleep patterns were assessed across 77 nights. Subjects participated in a single night of in-lab PSG and two nights of at-home data collection. The Happy Ring includes sensors for skin conductance, movement, heart rate, and skin temperature. The Happy Ring utilized two machine-learning derived scoring algorithms: a “generalized” algorithm that applied broadly to all users, and a “personalized” algorithm that adapted to individual subjects’ data. Epoch-by-epoch analyses compared the wearable devices to in-lab PSG and to at-home EEG Headband. Results: Compared to in-lab PSG, the “generalized” and “personalized” algorithms demonstrated good sensitivity (94% and 93%, respectively) and specificity (70% and 83%, respectively). The Happy Personalized model demonstrated a lower bias and more narrow limits of agreement across Bland-Altman measures. Conclusion: The Happy Ring performed well at home and in the lab, especially regarding sleep/wake detection. The personalized algorithm demonstrated improved detection accuracy over the generalized approach and other devices, suggesting that adaptable, dynamic algorithms can enhance sleep detection accuracy.

8 September 2021 in Digital Biomarkers
Verified
Journal Article
Open access
PDF file
AHAaron Hadley
Aaron Hadley
DRDavid E. Riley
David E. Riley
DHDustin A. Heldman
Dustin A. Heldman
Introduction: Parkinson’s disease (PD) is poorly quantified by patients outside the clinic, and paper diaries have problems with subjective descriptions and bias. Wearable sensor platforms; however, can accurately quantify symptoms such as tremor, dyskinesia, and bradykinesia. Commercially available smartwatches are equipped with accelerometers and gyroscopes that can measure motion for objective evaluation. We sought to evaluate the clinical utility of a prescription smartwatch-based monitoring system for PD utilizing periodic task-based motor assessment. Methods: Sixteen patients with PD used a smartphone- and smartwatch-based monitoring system to objectively assess motor symptoms for 1 week prior to instituting a doctor recommended change in therapy and for 4 weeks after the change. After 5 weeks the participants returned to the clinic to discuss their results with their doctor, who made therapy recommendations based on the reports and his clinical judgment. Symptom scores were synchronized with the medication diary and the temporal effects of therapy on weekly and hourly timescales were calculated. Results: Thirteen participants successfully completed the study and averaged 4.9 assessments per day for 3 days per week during the study. The doctor instructed 8 participants to continue their new regimens and 5 to revert to their previous regimens. The smartwatch-based assessments successfully captured intraday fluctuations and short- and long-term responses to therapies, including detecting significant improvements (p < 0.05) in at least one symptom in 7 participants. Conclusions: The smartwatch-based app successfully captured temporal trends in symptom scores following application of new therapy on hourly, daily, and weekly timescales. These results suggest that validated smartwatch-based PD monitoring can provide clinically relevant information and may reduce the need for traditional office visits for therapy adjustment.

10 July 2013 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
AHAaron Hadley
Aaron Hadley
IKIlya Kolb
Ilya Kolb
DTDustin J. Tyler
Dustin J. Tyler
Objective. Laryngeal elevation protects the airway and assists opening of the esophagus during swallowing. The GH, thyrohyoid, and MH muscles provide a majority of this elevatory motion. This study applied functional electrical stimulation to the XII/C1 nerve complex using a nerve cuff electrode to determine the capabilities of neural stimulation to induce laryngeal elevation. Approach. Multi-contact FINE electrodes were implanted onto the XII/C1 nerve complex at locations proximal and distal to the thyrohyoid branching point in five anesthetized canines. Motion of the thyroid cartilage and the hyoid bone was recorded during stimulation of nerve cuffs and intramuscular electrodes. Main Results. Nerve stimulation induced 260% more laryngeal elevation than intramuscular stimulation (18.8 mm versus 5.2 mm, p ≪ 0.01), and 228% higher velocity (143.8 versus 43.9 mm s–1, p ≪ 0.01). While stimulation at all cuff and electrode locations elevated the larynx, only the proximal XII/C1 nerve cuff significantly elicited both thyroid–hyoid approximation and hyoid elevation. In all proximal XII/C1 nerve cuffs (n = 7), stimulation was able to obtain selectivity of greater than 75% of at least one elevatory muscle. Significance. These results support the hypothesis that an implanted neural interface system can produce increased laryngeal elevation, a significant protective mechanism of deglutition.

25 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
AHAaron Hadley
Aaron Hadley
CPChristopher L Pulliam
Christopher L Pulliam
The generalizability of machine learning (ML) models for wearable monitoring in stroke rehabilitation is often constrained by the limited scale and heterogeneity of available data. Data augmentation addresses this challenge by adding computationally derived data to real data to enrich the variability represented in the training set. Traditional augmentation methods, such as rotation, permutation, and time-warping, have shown some benefits in improving classifier performance, but often fail to produce realistic training examples. This study employs Conditional Generative Adversarial Networks (cGANs) to create synthetic kinematic data from a publicly available dataset, closely mimicking the experimentally measured reaching movements of stroke survivors. This approach not only captures the complex temporal dynamics and common movement patterns after stroke, but also significantly enhances the training dataset. By training deep learning models on both synthetic and experimental data, we enhanced task classification accuracy: models incorporating synthetic data attained an overall accuracy of 80.0%, significantly higher than the 66.1% seen in models trained solely with real data. These improvements allow for more precise task classification, offering clinicians the potential to monitor patient progress more accurately and tailor rehabilitation interventions more effectively.

25 January 2015 in Dysphagia
Verified
Journal Article
Closed access
PDF file
AHAaron Hadley
Aaron Hadley
KKKate R. Krival
Kate R. Krival
ARAngela L. Ridgel
Angela L. Ridgel
EHElizabeth C. Hahn
Elizabeth C. Hahn
DTDustin J. Tyler
Dustin J. Tyler

1 January 2022 in medRxiv
Verified
Preprint
Open access
PDF file
Michael GrandnerMichael Grandner
Michael Grandner
ZBZohar Bromberg
Zohar Bromberg
AHAaron Hadley
Aaron Hadley
ZMZoe Morrell
Zoe Morrell
AGArnulf Graf
Arnulf Graf
DFDustin Freckleton
Dustin Freckleton
Study Objectives: Wearable sleep technology has rapidly expanded across the consumer market due to advances in technology and increased interest in personalized sleep assessment to improve health and mental performance. In this study, we tested the performance of a novel device, the Happy Ring, alongside other commercial wearables, against in-lab polysomnography (PSG) and an at-home EEG-derived sleep monitoring device, the Dreem 2 Headband. Methods: 36 healthy adults with no diagnosed sleep disorders and no recent use of medications or substances known to affect sleep pattern were assessed across 77 nights while wearing the Happy Ring, as well as a set of other consumer wearable devices. Subjects participated in a single night of in-lab PSG and 2 nights of at-home data collection. The Happy Ring includes sensors for skin conductance, movement, heart rate, and skin temperature. The Happy Ring utilized two machine-learning derived scoring algorithms: a “generalized” algorithm that applied broadly to all users, and a “personalized” algorithm that adapted to individual subjects’ data. Epoch-by-epoch analyses compared the wearable devices to both in-lab PSG and to the Dreem 2 EEG Headband (“Dreem 2 Headband”) at home. Results: Compared to in-lab PSG, the “generalized” and “personalized” algorithms demonstrated good sensitivity (94% and 93%, respectively) and specificity (70% and 83%, respectively). Accuracy was 91% for “generalized” and 92% for “personalized” algorithms. The generalized algorithm demonstrated an accuracy of 67%, 85%, and 85% for light, deep, and REM sleep, respectively. The personalized algorithm was 81%, 95%, and 92% accurate for light, deep, and REM sleep, respectively. Conclusions: The Happy Ring performed well at home and in the lab, especially regarding sleep detection. The personalized algorithm demonstrated improved detection accuracy over the generalized approach and other devices, suggesting that adaptable, dynamic algorithms can enhance sleep detection accuracy.