Sea cucumbers, like other echinoderms, have the ability to rapidly and reversibly alter the stiffness of their inner dermis. It has been proposed that the modulus of this tissue is controlled by regulating the interactions among collagen fibrils, which reinforce a low-modulus matrix. We report on a family of polymer nanocomposites, which mimic this architecture and display similar chemoresponsive mechanic adaptability. Materials based on a rubbery host polymer and rigid cellulose nanofibers exhibit a reversible reduction by a factor of 40 of the tensile modulus, for example, from 800 to 20 megapascals (MPa), upon exposure to a chemical regulator that mediates nanofiber interactions. Using a host polymer with a thermal transition in the regime of interest, we demonstrated even larger modulus changes (4200 to 1.6 MPa) upon exposure to emulated physiological conditions.
Electrical stimulation, using patterned intensity, applied through cuff-type peripheral nerve interfaces provided stable touch perceptions in the fingers, thumb, and hand of two subjects with upper limb loss for 16 to 24 months.
One of the important goals of peripheral nerve electrode development is to design an electrode for selective recruitment of the different functions of a common nerve trunk. A challenging task is gaining selective access to central axon populations. In this paper, a simple electrode that takes advantage of the neural plasticity to reshape the nerve is presented. The flat interface nerve electrode (FINE) reshapes the nerve into a flat geometry to increase the surface area and move central axon populations close to the surface. The electrode was implanted acutely on the sciatic nerve of eight cats. The FINE can significantly reshape the nerve and fascicles (p<0.0001) while maintaining the same total nerve cross-sectional area. The stimulation thresholds were 2.89 nC for pulse amplitude modulation and 10.2 nC for pulsewidth modulation. Monopolar, square-pulse stimulation with single contacts on the FINE selectively recruited each of the four main branches of the sciatic nerve. Simultaneous stimulation with two contacts produced moments about the ankle joint that were a combination of the moments produced by the individual contacts when stimulated separately.
Electrical connections between nerves and a prosthetic device enable amputees to discern precise, graded sensory intensity ranging from light touch to intense pressure.
The mechanisms underlying intracortical microelectrode encapsulation and failure are not well understood. A leading hypothesis implicates the role of the mechanical mismatch between rigid implant materials and the much softer brain tissue. Previous work has established the benefits of compliant materials on reducing early neuroinflammatory events. However, recent studies established late onset of a disease-like neurodegenerative state. In this study, we implanted mechanically-adaptive materials, which are initially rigid but become compliant after implantation, to investigate the long-term chronic neuroinflammatory response to compliant intracortical microelectrodes. Three days after implantation, during the acute healing phase of the response, the tissue response to the compliant implants was statistically similar to that of chemically matched stiff implants with much higher rigidity. However, at two, eight, and sixteen weeks post-implantation in the rat cortex, the compliant implants demonstrated a significantly reduced neuroinflammatory response when compared to stiff reference materials. Chronically implanted compliant materials also exhibited a more stable blood-brain barrier than the stiff reference materials. Overall, the data show strikingly that mechanically-compliant intracortical implants can reduce the neuroinflammatory response in comparison to stiffer systems.