Teoman Kilic

Prof. Teoman Kilic


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2006 in Heart
Verified
Journal Article
Closed access
PDF file
TKTeoman Kilic
Teoman Kilic
DUD Ural
D Ural
EUE Ural
E Ural
ZYZ Yumuk
Z Yumuk
AAA Agacdiken
A Agacdiken
BKB Komsuoglu
B Komsuoglu
Objective: To investigate the relation between serum high sensitivity (hs) C reactive protein (CRP), proinflammatory cytokine concentrations, proinflammatory to anti-inflammatory cytokine ratios and long-term prognosis in patients with non-ST elevation acute coronary syndrome (NSTEACS). Design: Prospective follow-up study for the first six months and then for the first year after admission to hospital. Setting: Tertiary referral centre. Patients: 80 patients (60 men, 20 women, mean age 60 (SD 10) years) with NSTEACS and moderate to high TIMI (Thrombolysis In Myocardial Infarction) risk scores. Interventions: Blood samples from patients with NSTEACS were obtained at the time of admission. Serum concentrations of hs-CRP, (hs) pro-inflammatory (interleukin (IL) -1β, IL-6, tumour necrosis factor α) and (hs) anti-inflammatory (IL-10) cytokines were analysed and proinflammatory to anti-inflammatory cytokine ratios were calculated by dividing proinflammatory cytokine concentrations by anti-inflammatory cytokine IL-10. Main outcome measure: The primary end point of the study was new coronary events (NCE) defined as the combination of cardiac death, non-fatal myocardial infarction and recurrent rest angina that required hospitalisation within 12 months of follow up. Results: During the one-year follow-up period, 23 patients (29%) met the NCE criteria. Concentrations of hs-CRP, IL-1β and IL-6 and ratios of IL-1β:IL-10 and IL-6:IL-10 were significantly higher in patients with NCE than in patients without NCE. In the logistic regression analysis, IL-6:IL-10 ratio was the most important predictor for NCE (p = 0.006) with an odds ratio of 2.24 (95% CI 1.26 to 3.97). Conclusions: Cytokine concentrations and proinflammatory to anti-inflammatory cytokine ratios may be useful markers for predicting vascular risk in patients with NSTEACS.

1 October 2022 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
SHSebastien Hascoet
Sebastien Hascoet
GSGrzegorz Smolka
Grzegorz Smolka
DBDavid Blanchard
David Blanchard
MKMartin Kloëckner
Martin Kloëckner
EBEric Brochet
Eric Brochet
BGBenoît Gérardin
Benoît Gérardin
Background: Transcatheter closure of a symptomatic prosthetic paravalvular leak (PVL) is feasible, but there is presently no conclusive evidence to show consistent efficacy. We aimed to identify predictors of clinical success after transcatheter PVL closure. Methods: Consecutive patients referred to 24 European centers for transcatheter PVL closure in 2017 to 2019 were included in a prospective registry ( Fermeture de Fuite ParaProthétique , FFPP). Clinical success was absence of any of the following within 1 month: re-admission for heart failure, blood transfusion, open-heart valvular surgery, and death. Results: We included 216 symptomatic patients, who underwent 238 percutaneous PVL closure procedures on the mitral (64.3%), aortic (34.0%), or tricuspid (1.7%) valve. Symptoms were heart failure, hemolytic anemia, or both in 48.9%, 7.8%, and 43.3% of patients, respectively. One, 2, and 3 leaks were treated during the same procedure in 69.6%, 26.6%, and 3.8% of patients, respectively. The PVL was pinpoint or involved 1/8 or 1/4 of the valve circumference in 18.6%, 52.4%, and 28.1% of cases, respectively. The most frequently used devices were the Vascular Plug 3, Ventricular Septal Defect Occluder, Vascular Plug 2, and Paravalvular Leak Device (45.0%, 16.6%, 14.2%, and 13.6% of cases, respectively). Successful device(s) implantation with leak reduction to ≤grade 2 was obtained in 85.0% of mitral and 91.4% of aortic procedures, respectively ( P =0.164); with major periprocedural adverse event rates of 3.3% and 1.2%, respectively ( P =0.371); and clinical success rates of 70.3% and 88.0%, respectively ( P =0.004). By multivariate analysis, technical failure, mechanical valve, and hemolytic anemia were independently associated with absence of clinical success (odds ratios [95% CIs], 7.7 [2.0–25.0]; P= 0.002; 3.6 [1.1–11.1]; P =0.036; and 3.7 [1.2–11.9]; P =0.025; respectively). Conclusions: Transcatheter PVL closure is efficient and safe in symptomatic patients but is associated with a lower clinical success rate in patients with hemolysis and/or a mechanical valve. Registration: URL: https://www.clinicaltrials.gov ; Unique identifiers: NCT05089136

23 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SHSebastien Hascoet
Sebastien Hascoet
GSGrzegorz Smolka
Grzegorz Smolka
TKTeoman Kilic
Teoman Kilic
Reda IbrahimReda Ibrahim
Reda Ibrahim
EOEustaquio Maria Onorato
Eustaquio Maria Onorato
BGBenoit Gerardin
Benoit Gerardin
Prosthetic paravalvular leaks (PVLs) are associated with congestive heart failure and hemolysis. Surgical PVL closure carries high risks. Transcatheter implantation of occluding devices in PVL is a lower risk but challenging procedure. Of the available devices, only two have been specifically approved in Europe for transcatheter PVL closure (tPVLc): the Occlutech® Paravalvular Leak Device (PLD) and Amplatzer™ ParaValvular Plug 3 (AVP 3). Here, we review the various tools and devices used for tPVLc, based on three observational registries including 748 tPVLc procedures performed in 2005–2021 at 33 centres in 11 countries. In this case, 12 registry investigators with over 20 tPVLc procedures each described their practical tips and tricks regarding imaging, approaches, delivery systems, and devices. They considered three-dimensional echocardiography to be the cornerstone of PVL assessment and procedure guidance. Anterograde trans-septal mitral valve and retrograde aortic approaches were used in most centres, although some investigators preferred the transapical approach. Hydrophilic-coated low-profile sheaths were used most often for device deployment. The AVP 3 and PLD devices were chosen for 89.0% of procedures. Further advances in design and materials are awaited. These complex procedures require considerable expertise, and experience accumulated over a decade has no doubt contributed to improve practices.

18 June 2007 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
TKTeoman Kilic
Teoman Kilic
AVAhmet Vural
Ahmet Vural
DUDilek Ural
Dilek Ural
TSTayfun Sahin
Tayfun Sahin
AAAysen Agacdiken
Aysen Agacdiken
BKBaki Komsuoglu
Baki Komsuoglu

1 March 2017
Verified
Journal Article
Open access
TKTeoman Kilic
Teoman Kilic
IYIrem Yilmaz
Irem Yilmaz
Transcatheter aortic valve implantation (TAVI) represents a real revolution in the field of interventional cardiology for the treatment of elderly or high-risk surgical patients with severe symptomatic aortic valve stenosis. Today, TAVI seems to play a key and a reliable role in the treatment of intermediate and maybe low-risk patients with severe aortic stenosis. TAVI has also evolved from a complex and hazardous procedure into an effective and safe therapy by the development of new generation devices. This article aims to review the background and future of TAVI, clinical trials and registries with old and new generation TAVI devices and to focus on some open issues related to post-procedural outcomes.

4 March 2024 in Archives of Medical Science
Verified
Journal Article
Open access
TKTeoman Kilic
Teoman Kilic
AIAlfonso Ielasi
Alfonso Ielasi
VNVlasis Ninios
Vlasis Ninios
LKLevent Korkmaz
Levent Korkmaz
DPDemosthenes Panagiotakos
Demosthenes Panagiotakos
AAAli Rıza Akyüz
Ali Rıza Akyüz
Introduction: Limited data exist on long-term follow-up of severe aortic stenosis (SAS) patients who have undergone transcatheter aortic valve implantation (TAVI) with a new generation, balloon expandable Myval transcatheter heart valve (THV). Thus, we sought to investigate the performance and 2-year clinical outcome of the Myval THV system based on Valve Academic Research Consortium-3 (VARC-3) criteria.Material and methods: A multi-centre, registry-based, observational study was conducted, which included 207 consecutive degenerative SAS patients, from Turkey (n = 128), Italy (n = 58), and Greece (n = 21) (mean [standard deviation] 81 (7) years, 94 [45%] men; 73% NYHA III or IV; EuroSCORE II 5.2% [2.4%]); all patients underwent TAVI with Myval. Patients were followed up at 1 year and 2 years after implantation. Clinical and procedural outcomes were defined according to VARC-3 criteria.Results: Technical success was observed in 204 (99%), device success was observed in 189 (91%), early safety was observed in 161 (78%), and clinical efficacy was observed in 163 (79%) patients. The 30-day death rate was 7.7%; of these, 3.4% were due to cardiovascular reasons. All-cause and cardiovascular mortality rates were 9.7% and 4.3% at 1-year follow-up, and 17.4% and 9.7% at 2-year follow-up, respectively. Incidence of ≥ moderate paravalvular leak (PVL) at 30 days, 1 year and 2 years of follow-up were 3.4%, 4.3% and 4.8%. A total of 11.1% of patients required a permanent pacemaker implantation (PPI) at 30 days after implantation, while the cumulative rate of PPI at 2 years was 12.1%.Conclusions: In this cohort of patients with SAS, the Myval was found to be safe and effective in up to 2 years of follow-up.