The acquisition of physiological data are essential to efficiently predict and treat cardiac patients before a heart attack occurs and effectively expedite motor recovery after a stroke. This goal can be achieved by using wearable wireless sensor network platforms for real-time healthcare monitoring. In this paper, we present a wireless physiological signal acquisition device and a smartphone-based software platform for real-time data processing and monitor and cloud server access for everyday ECG/EMG signal monitoring. The device is implemented in a compact size (diameter: 30 mm, thickness: 4.5 mm) where the biopotential is measured and wirelessly transmitted to a smartphone or a laptop for real-time monitoring, data recording and analysis. Adaptive digital filtering is applied to eliminate any interference noise that can occur during a regular at-home environment, while minimizing the data process time. The accuracy of ECG and EMG signal coverage is assessed using Bland–Altman analysis by comparing with a reference physiological signal acquisition instrument (RHS2116 Stim/Recording System, Intan). Signal coverage of R-R peak intervals showed almost identical outcome between this proposed work and the RHS2116, showing a mean difference in heart rate of 0.15 ± 4.65 bpm and a Wilcoxon’s p value of 0.133. A 24 h continuous recording session of ECG and EMG is conducted to demonstrate the robustness and stability of the device based on extended time wearability on a daily routine.
Haptic interface technologies for virtual reality applications have been developed to increase the reality and manipulability of a virtual object by creating a diverse tactile sensation. Most evaluation of the haptic technologies, however, have been limited to the haptic perception of the tactile stimuli via static virtual objects. Noting this, we investigated the effect of lateral cutaneous feedback, along with kinesthetic feedback on the perception of virtual object weight during manipulation. We modeled the physical interaction between a participant’s finger avatars and virtual objects. The haptic stimuli were rendered with custom-built haptic feedback systems that can provide kinesthetic and lateral cutaneous feedback to the participant. We conducted two virtual object manipulation experiments, 1. a virtual object manipulation with one finger, and 2. the pull-out and lift-up of a virtual object grasped with a precision grip. The results of Experiment 1 indicate that the participants felt the virtual object rendered with lateral cutaneous feedback significantly heavier than with only kinesthetic feedback (p < 0.05 formref = 100 and 200 g). Similarly, the participants of Experiment 2 felt the virtual objects significantly heavier when lateral cutaneous feedback was available (p < 0.05 formref = 100, 200, and 300 g). Therefore, the additional lateral cutaneous feedback to the force feedback led the participants to feel the virtual object heavier than without the cutaneous feedback. The results also indicate that the contact force applied to a virtual object during manipulation can be a function of the perceived object weight (p = 0.005 for Experiment 1 andp = 0.02 for Experiment 2).
25 September 2020 in Frontiers in Bioengineering and Biotechnology
We propose a novel wearable robotic glove or exo-glove design scalable to the variation of the hand kinematics. While most of the traditional robot hand is driven by rotating the joint directly with a rigid body, our exo-glove deforms a robotic finger's skin and, thus, the hand skeleton joints. Multiple tendons woven on the exo-glove's surface can make multi-DOF finger joint motions. We allocated tendons to mimic a hand's intrinsic and extrinsic muscles. Thus, a robotic hand actuated with the exo-glove can perform natural finger motions, including abduction/adduction and flexion/extension of finger joints. Moreover, additional tendons for the thumb enable power grips and the robotic hand's human-like motion. The proposed design approach places all the actuators on the surface without directly actuating any of the hand skeleton's joint. Therefore, a random hand skeleton can work as a robotic hand by putting the wearable robotic glove on it. Thus, the proposed model provides a high degree of freedom on choosing hand skeletons. We expect the aforementioned biomimetic features of our proposed method will benefit not only traditional robotic hands design but also the design of prosthetic hands and robot power-assisted hand glove.
Recent advances in big data technology collecting and analyzing large amounts of valuable data have attracted a lot of attention. When the information in non-reachable areas is required, IoT wireless sensor network technologies have to be applied. Sensors fundamentally have energy limitations, and it is almost impossible to replace energy-depleted sensors that have been deployed in an inaccessible region. Therefore, moving healthy sensors into the sensing hole will recover the faulty sensor area. In rough surfaces, hopping sensors would be more appropriate than wheel-driven mobile sensors. Sensor relocation algorithms to recover sensing holes have been researched variously in the past. However, the majority of studies to date have been inadequate in reality, since they are nothing but theoretical studies which assume that all the topology in the network is known and then computes the shortest path based on the nonrealistic backing up knowledge—The topology information. In this paper, we first propose a distributed hopping sensor relocation protocol. The possibility of movement of the hopping sensor is also considered to recover sensing holes and is not limited to applying the shortest path strategy. Finally, a performance analysis using OMNeT++ has demonstrated the solidification of the excellence of the proposed protocol.
This paper proposes a wireless power transfer (WPT) system by placing repeater coils to transfer power to multiple loads for the internet of things (IoT) devices and sensors in smart grid applications. The proposed system intermediate resonators (repeaters) not only function as power relays to enhance the transfer distance but also supplies power to its load attached to them. Equal power distribution and load-independent characteristics were obtained without efficiency degradation when any one of the loads was changed during system operation. Identical high-quality factor coils were designed using Litz-wire to reduce the skin effect. The coil size was 15.5 cm × 15.5 cm and the four relays achieved total efficiency of 51.7%, delivering 2 W power and output voltage of 5 V to each load with a total power transfer distance of 62 cm.