Young-Joon Kim

Dr. Young-Joon Kim

Gachon University
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2015 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Young-Joon KimYoung-Joon Kim
Young-Joon Kim
DHDohyuk Ha
Dohyuk Ha
WCWilliam J. Chappell
William J. Chappell
PIPedro P. Irazoqui
Pedro P. Irazoqui
In a multiple-receiver wireless power transfer (WPT) system, determining the condition for uniform power distribution at a high transfer efficiency is a challenging issue. In this paper, a selective WPT technique using magnetic resonance coupling (MRC) is introduced for smart power delivery in a multiple-receiver system. The proposed method selectively and exclusively delivers power to only one designated receiver among multiple receivers, eliminating the cross-coupling effect and unbalanced power division problem across the receivers. This is achieved by separating the resonant frequencies of the receivers to isolate the coupling effects between coils. The power division ratio of the receivers is controlled by changing the duration time ratio for power transfer. In this paper, a one-transmitter three-receiver selective MRC system is designed and fabricated. The power distribution is demonstrated under impedance matched condition, showing a power transfer efficiency of 24%-29% at a very small coupling coefficient of 0.01 with a 12-mm-diameter receiver coil. Distance compensation and a one-way communication of time division multiple access are demonstrated for a multiple-receiver system, using the proposed method.

28 October 2022 in Comparative Biochemistry and Physiology Part C: Toxicology & Pharmacology
Verified
Journal Article
Closed access
CSChendruru Geya Sree
Chendruru Geya Sree
VBViswanath Buddolla
Viswanath Buddolla
Buddolla Anantha LakshmiBuddolla Anantha Lakshmi
Buddolla Anantha Lakshmi
Young-Joon KimYoung-Joon Kim
Young-Joon Kim

27 March 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
K TheyagarajanK Theyagarajan
K Theyagarajan
Young-Joon KimYoung-Joon Kim
Young-Joon Kim
Electrochemical biosensors are superior technologies that are used to detect or sense biologically and environmentally significant analytes in a laboratory environment, or even in the form of portable handheld or wearable electronics. Recently, imprinted and implantable biosensors are emerging as point-of-care devices, which monitor the target analytes in a continuous environment and alert the intended users to anomalies. The stability and performance of the developed biosensor depend on the nature and properties of the electrode material or the platform on which the biosensor is constructed. Therefore, the biosensor platform plays an integral role in the effectiveness of the developed biosensor. Enormous effort has been dedicated to the rational design of the electrode material and to fabrication strategies for improving the performance of developed biosensors. Every year, in the search for multifarious electrode materials, thousands of new biosensor platforms are reported. Moreover, in order to construct an effectual biosensor, the researcher should familiarize themself with the sensible strategies behind electrode fabrication. Thus, we intend to shed light on various strategies and methodologies utilized in the design and fabrication of electrochemical biosensors that facilitate sensitive and selective detection of significant analytes. Furthermore, this review highlights the advantages of various electrode materials and the correlation between immobilized biomolecules and modified surfaces.

16 July 2015 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
Young-Joon KimYoung-Joon Kim
Young-Joon Kim
HBHansraj S. Bhamra
Hansraj S. Bhamra
JJJithin Joseph
Jithin Joseph
PIPedro P. Irazoqui
Pedro P. Irazoqui
An ultra-low-power wirelessly powered radiofrequency (RF) transceiver for wireless sensor network is implemented using 180-nm CMOS technology. We propose a 98-μW 457.5-MHz transmitter with output radiation power of -22 dBm. This transmitter utilizes 915-MHz wirelessly powering RF signal by frequency division using a true-single-phase-clock divider to generate the carrier frequency with very low power consumption and small die area. The transmitter can support up to 5-Mb/s data rate. The telemetry system uses an eight-stage Cockcroft-Walton rectifier to convert RF to dc voltage for energy harvesting. The bandgap reference and linear regulators provide stable dc voltage throughout the system. The receiver recovers data from the modulated wireless powering RF signal to perform time-division multiple access (TMDA) for the multiple-node system. Power consumption of the TDMA receiver is less than 15 μW. Our proposed transmitter and receiver each occupies 0.0018 and 0.0135 mm 2 of active die area, respectively.

15 October 2015 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
HBHansraj Bhamra
Hansraj Bhamra
Young-Joon KimYoung-Joon Kim
Young-Joon Kim
JJJithin Joseph
Jithin Joseph
JLJohn Lynch
John Lynch
OGOren Z. Gall
Oren Z. Gall
PIPedro Irazoqui
Pedro Irazoqui
We present a batteryless, crystal-free, time division multiple access (TDMA) synchronized multinode wireless body sensor node (WBSN) system-on-chip (SoC), referred to as a Bionode, for continuous and real-time telemetry of electromyograms (EMGs), enabling intuitive upper limb prosthesis control by an amputee. The SoC utilizes state of the art in supercapacitive RF energy harvesting, biosensing analog-front-end, switchingoptimized SAR ADC, ultra-low-power RF transceiver, and clock circuits. The sensor node SoCs are time synchronized with a base station, mounted on the prosthetic arm, by using the ultra-lowpower TDMA controller and receiver, and the digital core circuits. A 915 MHz broadcast RF signal is utilized to synthesize the carrier frequency of the transmitter. This along with the process and voltage compensated on-chip clock obviates the need for a bulky crystal oscillator, thus providing a low-cost and highly integrated solution to the WBSNs. The SoC is verified by capturing the EMG data from a healthy human body and consumes only 24 μW, while operating exclusively from the harvested RF energy. Implemented in a 0.18 μm CMOS process, the SoC occupies 2.025 mm2 silicon area. The sensor node has an extremely low weight and physical dimensions, thanks to the flexible carbon nanotube (CNT) supercapacitor, electrically small antenna (ESA), and crystal-free operation of the SoC.

24 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JWJeong Jin woo
Jeong Jin woo
WLWoochan Lee
Woochan Lee
Young-Joon KimYoung-Joon Kim
Young-Joon Kim
The acquisition of physiological data are essential to efficiently predict and treat cardiac patients before a heart attack occurs and effectively expedite motor recovery after a stroke. This goal can be achieved by using wearable wireless sensor network platforms for real-time healthcare monitoring. In this paper, we present a wireless physiological signal acquisition device and a smartphone-based software platform for real-time data processing and monitor and cloud server access for everyday ECG/EMG signal monitoring. The device is implemented in a compact size (diameter: 30 mm, thickness: 4.5 mm) where the biopotential is measured and wirelessly transmitted to a smartphone or a laptop for real-time monitoring, data recording and analysis. Adaptive digital filtering is applied to eliminate any interference noise that can occur during a regular at-home environment, while minimizing the data process time. The accuracy of ECG and EMG signal coverage is assessed using Bland–Altman analysis by comparing with a reference physiological signal acquisition instrument (RHS2116 Stim/Recording System, Intan). Signal coverage of R-R peak intervals showed almost identical outcome between this proposed work and the RHS2116, showing a mean difference in heart rate of 0.15 ± 4.65 bpm and a Wilcoxon’s p value of 0.133. A 24 h continuous recording session of ECG and EMG is conducted to demonstrate the robustness and stability of the device based on extended time wearability on a daily routine.