Modifying surface topography to prevent surface-induced thrombosis in cardiovascular implants allows endothelialization, which is the natural thrombo-resistance of blood-contacting surfaces, and is deemed to be the only long-term solution for hemocompatible materials. We adapted a simulation framework to predict platelet deposition on a modified surface and developed an optimization strategy to promote endothelial retention and limit platelet deposition. Under supraphysiological bulk shear stress, a maximum of 79% linear coverage was achieved. This study concludes that the addition of microtrenches promotes endothelial retention and can be improved through the optimal selection of geometric parameters.
Modifying surface topography to prevent surface-induced thrombosis in cardiovascular implants allows endothelialization, which is the natural thrombo-resistance of the blood-contacting surfaces and is deemed to be the only long-term hemocompatible material. We have adapted a simulation framework to predict platelet deposition on the modified surface and developed an optimization strategy to promote endothelial retention and limit platelet deposition. Under supraphysiological bulk shear stress, a maximum of 79% linear coverage was achieved. This study concludes that the addition of microtrenches promotes endothelial retention and can be improved through optimal selection of geometric parameters.
Maintaining a confluent, antithrombotic endothelium on cardiovascular biomaterial surfaces remains a major barrier to long-term hemocompatibility, as endothelial cells (ECs) rapidly denude under supraphysiological shear in prosthetic devices. Here, we hypothesized that mesoscale surface geometry (∼100–200 µm) could reorganize near-wall hemodynamics, preserving endothelial coverage and function under extreme shear. Engineered microtrenches were introduced onto an implant biomaterial to generate spatially defined shear environments. Under supraphysiological near-wall shear (∼250 dyn/cm²), microtrenched geometries created attenuated shear and vorticity gradients. Endothelial monolayers were sustained in these flow domains for 120 hours, whereas flat controls rapidly denuded. Endothelial retention in 22.5° angled trenches increased dramatically, from an EC₅₀ of 33 to 101 dyn/cm². 45° angled trenches further increased endothelial shear resistance to an EC₅₀ of 207 dyn/cm². Endothelial monolayers demonstrated collective mechano-adaptation to ultra-high shear through VE-cadherin junction thickening and coordinated cytoskeletal and nuclear alignment. Mechanoadapted monolayers exhibited increased eNOS expression correlated with local shear and elevated nitrite production (45°: 50.4 ± 6.1 µM; 22.5°: 35.7 ± 3.3 µM; 0°: 28.4 ± 6.8 µM). In contrast, interfaces with abrupt shear transitions or elevated rotational flow exhibited reduced coverage, junctional thinning, and re-emergence of VCAM-1 and PAI-1, indicating inflammatory and pro-thrombotic activation. Structural, functional, and inflammatory readouts exhibited peak responses within a shared shear–vorticity regime. Multivariate regression identified shear–vorticity coupling as the dominant predictor of endothelial persistence, with optima clustering within a mechanical range (≈0.8–2.9 × 10⁶ dyn·cm⁻²·s⁻¹). These findings establish geometry-driven modulation of near-wall flow as a predictive, material-agnostic strategy for endothelialization and vasoprotection of high-shear cardiovascular implants.