Titanium alloys have traditionally been used in blood-contacting cardiovascular devices, including left ventricular assist devices (LVADs). However, titanium surfaces are susceptible to adverse coagulation, leading to thrombogenesis and stroke. To improve hemocompatibility, LVAD manufacturers introduced powder sintering on blood-wetted surfaces in the 1980s to induce endothelialization. This technique has been employed in multiple contemporary LVADs on the pump housing, as well as the interior and exterior of the inflow cannula. Despite the wide adoption of sintered titanium, reported biologic response over the past several decades has been highly variable and apparently unpredictable—including combinations of neointima, pseudoneoimtima, thrombus, and pannus. We present a history of sintered titanium used in LVAD, a review of accumulated clinical outcomes, and a synopsis of gross appearance and composition of various depositions found clinically and in animal studies, which is unfortunately confounded by the variability and inconsistency in terminology. Therefore, this review endeavors to introduce a unified taxonomy to harmonize published observations of biologic response to sintered titanium in LVADs. From these data, we are able to deduce the natural history of the biologic response to sintered titanium, toward development of a deterministic model of the genesis of a hemocompatible neointima.
Modifying surface topography to prevent surface-induced thrombosis in cardiovascular implants allows endothelialization, which is the natural thrombo-resistance of blood-contacting surfaces, and is deemed to be the only long-term solution for hemocompatible materials. We adapted a simulation framework to predict platelet deposition on a modified surface and developed an optimization strategy to promote endothelial retention and limit platelet deposition. Under supraphysiological bulk shear stress, a maximum of 79% linear coverage was achieved. This study concludes that the addition of microtrenches promotes endothelial retention and can be improved through the optimal selection of geometric parameters.
The three-dimensional flow around two bubbles placed in tandem in a viscous fluid is studied by direct numerical simulations. The effect of parameters including the Reynolds number of the bubble Re∈[50,200], the center-to-center distance of two bubbles S∈[1.25,6], and the aspect ratios of the bubbles χ∈[1,2.5] on the flow fields, the drag forces, and the equilibrium separation distances is analyzed. The results show that no obvious flow vortex appears behind the spherical bubble opposite to the sphere, indicating that the disturbance to the flow field is much weaker than that of the sphere. This difference can be mainly attributed to the free-slip boundary of the bubble surface. The increase in Reynolds number and the decrease in the separation distance mainly affect the pressure drag of the bubbles, rather than the viscous drag. An equilibrium distance exists between the two bubbles depending on the competition of the attraction effect of the wake and the repulsion effect of the potential flow, due to the fact that the drag force of the downstream bubble may larger than that of a single bubble at a short distance caused by the latter effect. When the bubble becomes non-spherical due to deformation, the increase in the bubble aspect ratio can significantly enhance the wake effect, while almost keep the potential flow effect almost unchanging. This reduces the drag of the downstream bubbles, thereby shortening the equilibrium distance between the bubbles. These findings provide an important theoretical basis for understanding the interactions between bubbles and the collective dynamics of bubbly flows.
Modifying surface topography to prevent surface-induced thrombosis in cardiovascular implants allows endothelialization, which is the natural thrombo-resistance of the blood-contacting surfaces and is deemed to be the only long-term hemocompatible material. We have adapted a simulation framework to predict platelet deposition on the modified surface and developed an optimization strategy to promote endothelial retention and limit platelet deposition. Under supraphysiological bulk shear stress, a maximum of 79% linear coverage was achieved. This study concludes that the addition of microtrenches promotes endothelial retention and can be improved through optimal selection of geometric parameters.