Manuel Schieder

Mr. Manuel Schieder

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2025 in Processes
Verified
Journal Article
Open access
PDF file
JUJulian Unterluggauer
Julian Unterluggauer
ABAdam Buruzs
Adam Buruzs
MSManuel Schieder
Manuel Schieder
VSVerena Sulzgruber
Verena Sulzgruber
MLMichael Lauermann
Michael Lauermann
CRChristoph Reichl
Christoph Reichl
Decarbonization of industrial processes by using high-temperature heat pumps is one of the most important pillars towards sustainable energy goals. Most heat pumps are based on the standard Carnot cycle which includes an expansion valve leading to irreversible dissipation and energetic losses. Especially for high-temperature applications, these losses increase significantly, and a replacement of the conventional throttle valve with an ejector, which is an alternative expansion device, for partial recovery of some of the pressure lost during the expansion, is investigated in this paper. However, designing such a device is complicated as the flow inside is subject to multiphase and supersonic conditions. Therefore, this paper aims to streamline an approach for designing ejectors for high-temperature heat pumps using numerical simulations. To showcase the application of the design procedure, an ejector, which is used to upgrade a standard cycle high-temperature heat pump with the synthetic refrigerant R1233zdE, is developed. To design the ejector heat pump, an interaction between a fast 1D design tool, a 1D heat pump cycle simulation, and a 2D CFD simulation is proposed. An ejector is designed for a sink temperature of 130 °C, which can potentially increase the COP of the heat pump by around 20%. Preliminary measurements at off-design conditions at 100 °C sink temperature are used to validate the design procedure. The pressure distribution inside the ejector is well captured, with relative errors around 4%. However, the motive nozzle mass flow was underpredicted by around 30%. To summarize, the presented approach can be used for designing ejectors of high-temperature heat pumps, although the numerical modeling has to be further developed by validation with experiments to improve the prediction of the motive mass flow.

10 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
JUJulian Unterluggauer
Julian Unterluggauer
MSManuel Schieder
Manuel Schieder
SGStefan Gutschka
Stefan Gutschka
SPStefan Puskas
Stefan Puskas
SVStefan Vogt
Stefan Vogt
BSBernhard Streibl
Bernhard Streibl
In order to reduce CO2 emissions in the brick manufacturing process, the effectiveness of the energy-intensive firing process needs to be improved. This can be achieved by enhancing the heat transfer in order to reduce firing times. As a result, current development of tunnel kilns is oriented toward fast firing as a long-term goal. However, a struggling building sector and complicated challenges, such as different requirements for product quality, have impeded developments in this direction. This creates potential for the further development of oven designs, such as improved airflow through the kiln. In this article, numerical flow simulations are used to investigate two different reconstruction measures and compare them to the initial setup. In the first measure, the kiln height is reduced, while in the second measure, the kiln cars are adjusted to alternate the height of the bricks so that every other pair of bricks is elevated, creating a staggered arrangement. Both measures are investigated to determine the effect on the heating rate compared to the initial configuration. A transient grid independence study is performed, ensuring numerical convergence and the setup is validated by experimental results from measurements on the initial kiln configuration. The simulations show that lowering the kiln height improves the heat transfer rate by 40%, while the staggered arrangement of the bricks triples it. This leads to an average brick temperature after two hours which is around 130 °C higher compared to the initial kiln configuration. Therefore, the firing time can be significantly reduced. However, the average pressure loss coefficient rises by 70% to 90%, respectively, in the staggered configuration.

22 October 2025 in Journal of Energy Storage
Verified
Journal Article
Open access
FGFabrizia Giordano
Fabrizia Giordano
ABAdam Buruzs
Adam Buruzs
MSManuel Schieder
Manuel Schieder
MGMaité Goderis
Maité Goderis
WBWim Beyne
Wim Beyne
TBTilman Barz
Tilman Barz