Máté Karnok

Mr. Máté Karnok


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PGPeter Gaal
Peter Gaal
TGTibor Gilinger
Tibor Gilinger
BNBálint Nagyillés
Bálint Nagyillés
RNRoland Nagymihály
Roland Nagymihály
ISImre Seres
Imre Seres
KOKaroly Osvay
Karoly Osvay
We developed a versatile 100 Hz laser system based on negatively and positively chirped pulse amplification. The few-cycle output provides pulses with 7.1 fs and 0.25 mJ, while the power output supports 26 fs pulses with 50 mJ. The energy as well as the pulse duration stability of the system are below 1%, while the pointing stability is within 25% of the diffraction-limited spot size. We also show applications in high repetition rate target development and preparation for a laser-generated X-ray source for industrial CT imaging.

5 February 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
TSTamas Somoskoi
Tamas Somoskoi
MFMiklós Füle
Miklós Füle
PGPeter Gaal
Peter Gaal
MKMáté Karnok
Máté Karnok
GKGergely Kovacs
Gergely Kovacs
KOKaroly Osvay
Karoly Osvay
Fe-based metallic glasses are ideal candidates to be utilized in transformer cores owing to their outstanding soft magnetic properties. However, they are difficult to machine properly by conventional means due to their mechanical brittleness and poor thermal conductivity. Here, the cutting of Fe91–Si4.5–C4.0–Al0.5 amorphous alloy ribbons is reported with a sub-50 fs laser pulses. A systematic study is performed on local morphological and chemical composition changes to the machined edge in comparison to crystalline metals. It is shown that only the innermost 80 μm wide region of the cut edge shows any detectable modifications, which is much less than for continuous laser machining. Therefore, the proposed method is indeed a valuable approach to overcome the fine machining difficulties of metallic glasses.

3 October 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
PGPeter Gaal
Peter Gaal
TGTibor Gilinger
Tibor Gilinger
BNBalint Nagyilles
Balint Nagyilles
RNRoland Nagymihaly
Roland Nagymihaly
ISImre Seres
Imre Seres
KOKaroly Osvay
Karoly Osvay
We developed a versatile 100 Hz laser system based on negatively and positively chirped pulse amplification. The few-cycle output provides pulses with 7.1 fs and 0.25 mJ, while the power output supports 26 fs pulses with 50 mJ. The energy as well as the pulse duration stability of the system is below 1%, while the pointing stability is within 25% of the diffraction limited spot size. We also show applications in high repetition rate target development and preparation for a laser-generated X-ray source for industrial CT imaging.