The paper focuses on material characterization and technology properties of a new Ti-12Al-42Nb spherical powder alloy for additive manufacturing of personal medical implants. The electrode induction melting inert gas atomization (EIGA) method was used to produce the powder alloy. The powder sphericity coefficient (PSC) was 1.02. Image J software was used to calculate the spherical degree by processing images sets from scanning electron microscopy (SEM) and optical microscopy (OM). SEM of particles cross-sections indicated internal thermal-induced porosity (TIP) with a 2.3 μm pore diameter. Particle size distribution was in the range from 15.72 μm (d10) to 64.48 μm (d100) as measured by laser particle analyzer. It was indicated that flowability and powder bulk density were 196 sec and 2.79 g/cm3, respectively. XRD analysis confirmed the beta phase of the powder alloy with no additional phases. X-ray fluorescence spectrometry confirmed the alloyed composition. Reducing and oxidative melting methods of analysis showed a slight amount of impurities: oxygen (0.0087 wt.%), nitrogen (0.03 wt.%), hydrogen (0.0012 wt.%), sulfur (0.0016 wt.%), and carbon (0.022 wt.%). Simultaneous thermal analysis (STA) was performed to indicate weight growth and losses and thermal effects in argon, nitrogen, and air as well as the oxidation of Al2O3, TiO2, and Nb2O5 on the surface layer of Ti-12Al-42Nb powder alloy particles. Different phase transformations of γAl2O3 → θAl2O3 → αAl2O3 and TiO2 rutile → TiO2 anatase phase transformation were detected by STA in the oxidative layer.

12 February 2026 in Materials
Verified
Journal Article
Open access
PDF file
AAAlexander Anokhin
Alexander Anokhin
AKAndrey Kirsankin
Andrey Kirsankin
EEElena Ermakova
Elena Ermakova
MCMariya Chuvikina
Mariya Chuvikina
АЛАлександр - Лукьянов
Александр - Лукьянов
JJJoydip Joardar
Joydip Joardar
The paper focuses on materials characterization and in vivo biocompatibility tests of Ti–6Al–7Nb–0.3REE wt.% alloys (REEs—Y, Ce, La) for use as a promising material to produce personalized medical implants and shed light on possible toxicity effects of REE alloy microdoping. All alloys were produced by the electric arc melting method and characterized by scanning electron microscopy (SEM), optical microscopy (OM), energy-dispersive X-ray spectroscopy analysis (EDX), X-ray diffraction (XRD), true density analysis, micro- and nanoindentation methods, and reducing/oxidation melting techniques. True density of alloys increased in the following order: Ti−6Al−7Nb−0.3Y (4.4563 ± 0.1075 g/cm3) < Ti−6Al−7Nb−0.3Ce (4.7255 ± 0.2853 g/cm3) < Ti−6Al−7Nb−0.3La (4.8019 ± 0.0111 g/cm3). XRD analysis indicated that Ti–6Al–7Nb–0.3Y alloy consisted of single α–Ti phase in comparison with Ti–6Al–7Nb–0.3La (α–Ti to β–Ti = 82 to 18) and Ti–6Al–7Nb–0.3Ce (α–Ti to β–Ti = 90.5 to 9.5). The single-phase Ti–6Al–7Nb–0.3Y alloy had the finest α–Ti phase crystallites (22.32 nm); the larger α–Ti crystallites in the dual-phase Ti–6Al–7Nb–0.3Ce and Ti–6Al–7Nb–0.3La (30.77 nm and 29.83 nm, respectively) suggested the presence of the β–Ti phase (23.34 nm and 25.61 nm, respectively). REE microdoping of alloys changed the lattice volume (∆V): α–Ti phase—0.269% for Ti–6Al–7Nb–0.3Y, 1.799% for Ti–6Al–7Nb–0.3Ce, 0.595% for Ti–6Al–7Nb–0.3La; and β–Ti phase—0.334% for Ti–6Al–7Nb–0.3Ce, 0.670% for Ti–6Al–7Nb–0.3La. Nanohardness (H) and elastic modulus (E) increased in the following order: Ti−6Al−7Nb−0.3La (4.01 GPa and 135 GPa, respectively) < Ti−6Al−7Nb−0.3Y (4.39 GPa and 137 GPa, respectively) < Ti−6Al−7Nb−0.3Ce (4.67 GPa and 146 GPa, respectively). In vivo tests were conducted using 46 sexually mature male Wistar rats by means of skin implantation of samples with d = 11 mm and h = 1 mm. Our research shows that Ti–6Al–7Nb–0.3La alloy (Group 2) and Ti–6Al–7Nb–0.3Ce alloy (Group 3) induced sustained hepatotoxic and nephrotoxic effects. Ti–6Al–7Nb–0.3Y alloy induced a slight local inflammatory response; however, serum biochemical analysis suggested this effect was compensated.

23 April 2026 in Genij Ortopedii
Verified
Journal Article
Open access
PDF file
AAAlexander Anokhin
Alexander Anokhin
NKNatalia Kononovich
Natalia Kononovich
ASA. L. Shastov
A. L. Shastov
EGE. N. Gorbach
E. N. Gorbach
EEE. A. Ermakova
E. A. Ermakova
NTN. V. Tushina
N. V. Tushina
Introduction Medical implants for treating injuries and orthopedic diseases are often made of titanium and its alloys. Their physicochemical properties, including corrosion inhibition, can be improved by adding rare earth elements. The aim of this study was to evaluate the safety of new materials based on the titanium alloy Ti6Al7Nb doped with yttrium, lanthanum, and cerium using an experimental in vivo subcutaneous implantation model. Materials and Methods Male Wistar rats were subcutaneously implanted with titanium and titanium alloy samples: VT1-00 (control, n = 10); Ti6Al7Nb0.3Y (group 1, n = 12); Ti6Al7Nb0.3La (group 2, n = 12); Ti6Al7Nb0.3Ce (group 3, n = 12). The experiment lasted 28 days. The animals' general condition and behavioral responses were assessed, and the implantation area was visually marked. Body weight, body temperature, and local temperature at the implantation site were recorded. Hematological and biochemical blood tests were performed, and internal organs and peri-implant tissue condition were anatomically assessed. Results In all groups, general condition, behavioral responses, body weight, body temperature, and peri-implant tissue temperature were normal, and skin wound healing occurred by primary intention. A positive effect of the rare earth elements studied was observed on reparative processes during skin wound healing. In the control group and group 1, organs retained normal size, color, and anatomical structure. In group 1, red blood cell counts were slightly elevated, along with increased concentrations of low- and medium-molecular-weight substances. In groups 2 and 3, changes in the anatomical characteristics of the liver, kidneys, and spleen were determined. Serum AST and LDH levels increased, C-reactive protein levels decreased, the proportion of neutrophils increased, and the lymphocyte count decreased. Glucose levels decreased in group 2, while glucose and urea levels increased in group 3. Discussion Subcutaneous implantation of yttrium (Y), lanthanum (La), and cerium (Ce) at 0.3 % wt. each in titanium alloys of Ti6Al7Nb composition for one month had no negative impact on the general condition, thermoregulation, cardiovascular system, or reproductive organs of male rats. The titanium alloy doped with yttrium (Y) had a compensatory toxic effect on the body. Titanium alloys doped with lanthanum (La) and cerium (Ce) exhibited hepatotoxic and nephrotoxic effects and impaired spleen function. The results obtained are consistent with existing literature data. Conclusion Under the conditions created, yttrium-doped materials and control samples can be considered safe. Materials doped with lanthanum and cerium raise concerns when implanted in vivo , requiring a longer-term study using histological methods.

11 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
AAAlexander Anokhin
Alexander Anokhin
AKAndrey Kirsankin
Andrey Kirsankin
EEElena Ermakova
Elena Ermakova
MCMariya Chuvikina
Mariya Chuvikina
АЛАлександр - Лукьянов
Александр - Лукьянов
JJJoydip Joardar
Joydip Joardar
The paper focuses on materials characterization and «in vivo» biocompatibility tests of Ti6Al7Nb alloys microdoped by 0.3 wt. % of rareearth elements (REE) to use it as perspective materials to produce personalized medical implants. All Ti6Al7Nb0.3REE alloys (REE Y, Ce, La) were produced by electric arc melting method and characterized by scanning electron microscopy (SEM), optical microscopy (OM), energy-dispersive Xray spectroscopy analysis (EDX), helium pycnometer as well as reducing/oxidation melting methods. The measured true densities increased in the order: Ti−6Al−7Nb−0.3Y (4.4563 ± 0.1075 g/cm³) < Ti−6Al−7Nb−0.3Ce (4.7255 ± 0.2853 g/cm³) < Ti−6Al−7Nb−0.3La (4.8019 ± 0.0111 g/cm³). Diffraction analysis was performed to indicate phases composition and calculate crystallites sizes, crystal orientation and lattice parameters that confirmed REEmicrodoping due to increase of lattice volume. The single-phase Ti6Al7Nb0.3Y alloy had the finest αTi crystallites (22.32 nm), the larger αTi crystallites in the dualphase Ti6Al7Nb0.3Ce and Ti6Al7Nb0.3La (30.77 nm and 29.83 nm, respectively) suggest that the presence of the βTi phase. Hardness (H) and elastic modulus (E) were indicated by nanoindentation and increased in the order: Ti−6Al−7Nb−0.3La (4.01 GPa and 17.7 GPa respectively) < Ti−6Al−7Nb−0.3Y (4.39 GPa and 137 GPa respectively ) < Ti−6Al−7Nb−0.3Ce (4,67 GPa and 146 GPa respectively). In vivo tests showed that Ti6Al7Nb0.3La alloy had statistically significant increase of local inflammation at the one-week mark needed to further research and explanation as well, that could be indicator of toxicity in comparison with other studied alloys.