Zhisheng Zhi Li

Dr. Zhisheng Zhi Li

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2024 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
ZLZhisheng Zhi Li
Zhisheng Zhi Li
Yuchun ZhangYuchun Zhang
Yuchun Zhang
Yunji GaoYunji Gao
Yunji Gao
LCLongfei Chen
Longfei Chen
TLTao Li
Tao Li

28 July 2022 in Fire Technology
Verified
Journal Article
Closed access
PDF file
ZLZhisheng Zhi Li
Zhisheng Zhi Li
Yuchun ZhangYuchun Zhang
Yuchun Zhang
HJHaokai Jiang
Haokai Jiang
CTChunhua Tang
Chunhua Tang
DLDenggang Luo
Denggang Luo
TLTao Li
Tao Li

7 June 2022 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
ZLZhisheng Zhi Li
Zhisheng Zhi Li
HJHaokai Jiang
Haokai Jiang
YCYanying Cheng
Yanying Cheng
YGYunji Gao
Yunji Gao
LCLongfei Chen
Longfei Chen
SXShaoshuai Xing
Shaoshuai Xing

2 October 2015 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Open access
YBYu Ban
Yu Ban
TKTimothy De Keulenaer
Timothy De Keulenaer
ZLZhisheng Zhi Li
Zhisheng Zhi Li
JKJoris Van Kerrebrouck
Joris Van Kerrebrouck
JSJeffrey H. Sinsky
Jeffrey H. Sinsky
GTGuy Torfs
Guy Torfs
A millimeter wave integrated transversal filter operating at up to 84 Gb/s is presented. The implemented topology offers improved testability, which allows for filter characterization in both the time and frequency domain. The filter has an input and output return loss better than 10 dB up to 67 GHz. Using this filter, frequency equalization of an NRZ input to either an NRZ or a duobinary output is demonstrated at 84 Gb/s across a channel consisting of a 5 cm differential grounded coplanar waveguide trace and a pair of 80 cm coaxial cables. The filter is implemented in 130 nm SiGe BiCMOS process, has a die area of 2.5 mm × 1.4 mm and consumes 210 mW from a 2.5 V power supply.

12 October 2021 in Combustion Science and Technology
Verified
Journal Article
Closed access
ZLZhisheng Zhi Li
Zhisheng Zhi Li
Yuchun ZhangYuchun Zhang
Yuchun Zhang
HGHanwen Guo
Hanwen Guo
YLYouxin Lin
Youxin Lin
YCYanying Cheng
Yanying Cheng
TLTao Li
Tao Li
Previous studies have not sufficiently focused on the fire characteristics of different fire source elevations in a longitudinal ventilated tunnel fire, especially for a full-scale tunnel. In this work, a set of full-scale burning experiments were conducted to investigate the maximum temperature under the ceiling and longitudinal hot smoke temperature decay characteristics by considering the effect of heat release rate (HRRs), ambient wind velocity, and fire elevation. Experimental results show that the maximum temperature profile under the tunnel ceiling is mainly dependent on the interactions of HRRs, wind velocity, and fire elevation. The comparison of the maximum temperature model predicted by previous studies with these experimental data was conducted, which demonstrates that Li’s model is more appropriate to describe the maximum temperature under the ceiling. Moreover, the dimensionless longitudinal temperature decay rate of hot smoke induced by fire exhibits an obvious increasing trend with the fire elevation increases. A modified model of longitudinal temperature profile along the tunnel ceiling was put forward by considering the effect of fire elevation. The current work will provide some references for fire protection design and arrangement of alarm devices in an ambient ventilated tunnel fire caused by different vehicle heights.

3 December 2025 in Energy
Verified
Journal Article
Closed access
ZLZhisheng Zhi Li
Zhisheng Zhi Li
HLHaonan Li
Haonan Li
SLShuyun Lan
Shuyun Lan
YYYuwen Yan
Yuwen Yan
YZYuchun Zhang
Yuchun Zhang
WHWei Hou
Wei Hou