Rajendhar Junjuri

Dr. Rajendhar Junjuri

Physical chemistry, FSU Jena, Jena, Thuringia, Germany
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2024 in Molecules
Verified
Journal Article
Open access
PDF file
RVRavi teja Vulchi
Ravi teja Vulchi
VMVolodymyr Morgunov
Volodymyr Morgunov
RJRajendhar Junjuri
Rajendhar Junjuri
Thomas W. BocklitzThomas W. Bocklitz
Thomas W. Bocklitz
Raman spectroscopy, renowned for its unique ability to provide a molecular fingerprint, is an invaluable tool in industry and academic research. However, various constraints often hinder the measurement process, leading to artifacts and anomalies that can significantly affect spectral measurements. This review begins by thoroughly discussing the origins and impacts of these artifacts and anomalies stemming from instrumental, sampling, and sample-related factors. Following this, we present a comprehensive list and categorization of the existing correction procedures, including computational, experimental, and deep learning (DL) approaches. The review concludes by identifying the limitations of current procedures and discussing recent advancements and breakthroughs. This discussion highlights the potential of these advancements and provides a clear direction for future research to enhance correction procedures in Raman spectral analysis.

1 July 2020 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Open access
JVJakub Vrábel
Jakub Vrábel
EKErik Képeš
Erik Képeš
LDLudovic Duponchel
Ludovic Duponchel
VMVincent Motto-Ros
Vincent Motto-Ros
CFCécile Fabre
Cécile Fabre
JKJozef Kaiser
Jozef Kaiser

1 November 2020 in Waste Management
Verified
Journal Article
Closed access
RJRajendhar Junjuri
Rajendhar Junjuri
MGManoj Kumar Gundawar
Manoj Kumar Gundawar

1 July 2019 in Polymer Testing
Verified
Journal Article
Closed access
RJRajendhar Junjuri
Rajendhar Junjuri
CZChi Zhang
Chi Zhang
IBIshan Barman
Ishan Barman
MGManoj Kumar Gundawar
Manoj Kumar Gundawar

30 May 2019 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
RJRajendhar Junjuri
Rajendhar Junjuri
MGManoj Kumar Gundawar
Manoj Kumar Gundawar
We report the identification of five extensively used post-consumer plastics using the femtosecond laser-induced breakdown spectroscopy (fs-LIBS) technique. All the samples were obtained from a local recycling unit. An ultra-fast amplifier system delivering pulses of ∼50 fs duration was used for the investigation. Initially, a 2D scatter plot approach was employed in which a pair of selected spectral features was utilized to discriminate the samples. H–CN and C2–CN plots have shown promising discrimination. Apart from bivariate studies, principal component analysis (PCA) has been employed for the exploratory analysis where excellent segregation was achieved. Further, data were analysed using a supervised algorithm, artificial neural network (ANN). For efficient identification, an ANN model was constructed and evaluated by exploiting five different spectral windows/regions. The average identification rates obtained for all samples are in the range of 97 to 99% depending on the spectral window. The correct prediction rates with 100% accuracy were achieved when 10 prominent spectral features were employed. These findings demonstrate that the fs-LIBS combined with multivariate techniques can work as an efficient spectroscopic tool for the identification of post-consumer plastics.

11 December 2018 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
EMEshita Mal
Eshita Mal
RJRajendhar Junjuri
Rajendhar Junjuri
MGManoj Kumar Gundawar
Manoj Kumar Gundawar
AKAlika Khare
Alika Khare
In the present work, the transient evolution of laser induced plasmas (LIPs) of three different copper alloys are reported in order to identify the optimum temporal window for the implementation of calibration free laser induced breakdown spectroscopy (CF-LIBS) for quantitative analysis. The laser induced plasma (LIP) is generated on the copper alloys in air by focusing the second harmonic of a Q-switched Nd:YAG laser of pulse width ∼7 ns and a repetition rate of 1 Hz. From LIBS spectra it is observed that sample 1 (commercial brass) is comprised of copper (Cu) and zinc (Zn) as the major constituent elements along with the trace elements aluminum (Al), iron (Fe), lead (Pb), tin (Sn) and nickel (Ni), while sample 2 is comprised of Cu, Zn and Ni and sample 3 contains only two elements: Cu and Ni. The accuracy of the CF-LIBS technique depends immensely on the validity of local thermodynamic equilibrium (LTE) and the optically thin condition of the plasma. From the temporal evolution of the LIP, the optimum temporal window is identified where LTE as well as the condition of an optically thin plasma hold together. For this, the temporal evolution of the plasma temperature is studied from the emitted atomic copper transitions via a Boltzmann plot and that of the electron density from the Stark-broadened profile of the CuI (510.5 nm) line. The estimated plasma parameters are used in a one line CF-LIBS algorithm to determine the percentage composition of all the elements present in all three samples. Sample 1, comprising seven elements, is studied first at four different laser energies of 25, 50, 75 and 100 mJ. It is observed that the LTE and optically thin condition of the plasma are well satisfied in the optimum temporal window of 2–4 μs with respect to (w.r.t) the incidence of the laser pulse. The relative errors in the estimation of the concentrations of trace elements are at a minimum at 50 mJ compared to those at other energies. So the other two samples are studied at 50 mJ of laser energy only. The CF-LIBS results within this optimum temporal window for all the samples are also found to be in good agreement with the EDX results.