Manoj Kumar Gundawar

Manoj Kumar Gundawar

Auto-generated profile, based on publicly available information

Manoj Kumar Gundawar

University of Hyderabad

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2015 in Scientific Reports
Verified
Journal Article
Open access
AMAshwin Kumar Myakalwar
Ashwin Kumar Myakalwar
NSNicolas Spegazzini
Nicolas Spegazzini
CZChi Zhang
Chi Zhang
SASiva Kumar Anubham
Siva Kumar Anubham
RDRamachandra R. Dasari
Ramachandra R. Dasari
MGManoj Kumar Gundawar
Manoj Kumar Gundawar
Despite its intrinsic advantages, translation of laser induced breakdown spectroscopy for material identification has been often impeded by the lack of robustness of developed classification models, often due to the presence of spurious correlations. While a number of classifiers exhibiting high discriminatory power have been reported, efforts in establishing the subset of relevant spectral features that enable a fundamental interpretation of the segmentation capability and avoid the ‘curse of dimensionality’ have been lacking. Using LIBS data acquired from a set of secondary explosives, we investigate judicious feature selection approaches and architect two different chemometrics classifiers –based on feature selection through prerequisite knowledge of the sample composition and genetic algorithm, respectively. While the full spectral input results in classification rate ofca.92%, selection of only carbon to hydrogen spectral window results in near identical performance. Importantly, the genetic algorithm-derived classifier shows a statistically significant improvement toca.94% accuracy for prospective classification, even though the number of features used is an order of magnitude smaller. Our findings demonstrate the impact of rigorous feature selection in LIBS and also hint at the feasibility of using a discrete filter based detector thereby enabling a cheaper and compact system more amenable to field operations.

1 November 2020 in Waste Management
Verified
Journal Article
Closed access
RJRajendhar Junjuri
Rajendhar Junjuri
MGManoj Kumar Gundawar
Manoj Kumar Gundawar

30 May 2019 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
RJRajendhar Junjuri
Rajendhar Junjuri
MGManoj Kumar Gundawar
Manoj Kumar Gundawar
We report the identification of five extensively used post-consumer plastics using the femtosecond laser-induced breakdown spectroscopy (fs-LIBS) technique. All the samples were obtained from a local recycling unit. An ultra-fast amplifier system delivering pulses of ∼50 fs duration was used for the investigation. Initially, a 2D scatter plot approach was employed in which a pair of selected spectral features was utilized to discriminate the samples. H–CN and C2–CN plots have shown promising discrimination. Apart from bivariate studies, principal component analysis (PCA) has been employed for the exploratory analysis where excellent segregation was achieved. Further, data were analysed using a supervised algorithm, artificial neural network (ANN). For efficient identification, an ANN model was constructed and evaluated by exploiting five different spectral windows/regions. The average identification rates obtained for all samples are in the range of 97 to 99% depending on the spectral window. The correct prediction rates with 100% accuracy were achieved when 10 prominent spectral features were employed. These findings demonstrate that the fs-LIBS combined with multivariate techniques can work as an efficient spectroscopic tool for the identification of post-consumer plastics.

1 February 2020 in Optik
Verified
Journal Article
Closed access
RJRajendhar Junjuri
Rajendhar Junjuri
AGArun Prakash Gummadi
Arun Prakash Gummadi
MGManoj Kumar Gundawar
Manoj Kumar Gundawar

6 November 2017 in Defence Science Journal
Verified
Journal Article
Open access
PDF file
MGManoj Kumar Gundawar
Manoj Kumar Gundawar
RJRajendhar Junjuri
Rajendhar Junjuri
Ashwin kumar MyakalwarAshwin kumar Myakalwar
Ashwin kumar Myakalwar
We report the ‘standoff detection’ of explosives at 1 m in laboratory conditions, for the first time in India, using Laser Induced Breakdown Spectroscopy combined with multivariate analysis. The spectra of a set of five secondary explosives were recorded at a distance of 1 m from the focusing as well as collection optics. The plasma characteristics viz., plasma temperature and electron density were estimated from Boltzmann statistics and Stark broadening respectively. Plasma temperature was estimated to be of the order of (10.9 ± 2.1) .103 K and electron density of (3.9 ± 0.5) .1016 cm-3. Using a ratiometric approach, C/H and H/O ratios showed a good correlation with the actual stoichiometric ratios and a partial identification success could be achieved. Finally employing principle component analysis, an excellent classification could be attained.

31 March 2016 in The Analyst
Verified
Journal Article
Closed access
PDF file
Ashwin kumar MyakalwarAshwin kumar Myakalwar
Ashwin kumar Myakalwar
SASiva Kumar Anubham
Siva Kumar Anubham
SPSantosh K Paidi
Santosh K Paidi
IBIshan Barman
Ishan Barman
MGManoj Kumar Gundawar
Manoj Kumar Gundawar
Laser induced breakdown spectroscopy provides a novel route for the rapid identification of structural isomers.