Xue Ding

Ms. Xue Ding


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
YYYuichi Yoshida
Yuichi Yoshida
XDXue Ding
Xue Ding
KIKohei Iwatsuki
Kohei Iwatsuki
KTKatsuya Taniizumi
Katsuya Taniizumi
HIHirofumi Inoue
Hirofumi Inoue
Toshihiko KiwaToshihiko Kiwa
Toshihiko Kiwa
Cancer genome analysis has recently attracted attention for personalized cancer treatment. In this treatment, evaluation of the ratio of cancer cells in a specimen tissue is essential for the precise analysis of the genome. Conventionally, the evaluation takes at least two days and depends on the skill of the pathologist. In our group, a terahertz chemical microscope (TCM) was developed to easily and quickly measure the number of cancer cells in a solution. In this study, an antibody was immobilized on a sensing plate using an avidin-biotin reaction to immobilize it for high density and to improve antibody alignment. In addition, as the detected terahertz signals vary depending on the sensitivity of the sensing plate, the sensitivity was evaluated using pH measurement. The result of the cancer cell detection was corrected using the result of pH measurement. These results indicate that a TCM is expected to be an excellent candidate for liquid biopsies in cancer diagnosis.

19 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
XDXue Ding
Xue Ding
MMMana Murakami
Mana Murakami
jin wangjin wang
jin wang
HIHirofumi Inoue
Hirofumi Inoue
Toshihiko KiwaToshihiko Kiwa
Toshihiko Kiwa
In the detection of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), several methods have been employed, including the detection of viral ribonucleic acid (RNA), nucleocapsid (N) proteins, spike proteins, and antibodies. RNA detection, primarily through polymerase chain reaction tests, targets the viral genetic material, whereas antigen tests detect N and spike proteins to identify active infections. In addition, antibody tests are performed to measure the immune response, indicating previous exposure or vaccination. Here, we used the developed terahertz chemical microscope (TCM) to detect different concentrations of N protein in solution by immobilizing aptamers on a semiconductor substrate (sensing plate) and demonstrated that the terahertz amplitude varies as the concentration of N proteins increases, exhibiting a highly linear relationship with a coefficient of determination (R2 = 0.9881), indicating that a quantitative measurement of N proteins is achieved. By optimizing the reaction conditions, we confirmed that the amplitude of the terahertz wave was independent of the solution volume. Consequently, trace amounts (0.5 μL) of the N protein were successfully detected, and the detection process only took 10 min. Therefore, this study is expected to develop a rapid and sensitive method for the detection and observation of the SARS-CoV-2 virus at a microdetection level. It is anticipated that this research will significantly contribute to reducing the spread of novel infectious diseases in the future.