Suraj Dilip Serai

Dr. Suraj Dilip Serai

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2018 in Radiology
Verified
Journal Article
Closed access
TYTakeshi Yokoo
Takeshi Yokoo
SSSuraj Dilip Serai
Suraj Dilip Serai
APAli Pirasteh
Ali Pirasteh
MBMustafa R. Bashir
Mustafa R. Bashir
GHGavin Hamilton
Gavin Hamilton
FCFor the RSNA-QIBA PDFF Biomarker Committee
For the RSNA-QIBA PDFF Biomarker Committee
Purpose To determine the linearity, bias, and precision of hepatic proton density fat fraction (PDFF) measurements by using magnetic resonance (MR) imaging across different field strengths, imager manufacturers, and reconstruction methods. Materials and Methods This meta-analysis was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A systematic literature search identified studies that evaluated the linearity and/or bias of hepatic PDFF measurements by using MR imaging (hereafter, MR imaging-PDFF) against PDFF measurements by using colocalized MR spectroscopy (hereafter, MR spectroscopy-PDFF) or the precision of MR imaging-PDFF. The quality of each study was evaluated by using the Quality Assessment of Studies of Diagnostic Accuracy 2 tool. De-identified original data sets from the selected studies were pooled. Linearity was evaluated by using linear regression between MR imaging-PDFF and MR spectroscopy-PDFF measurements. Bias, defined as the mean difference between MR imaging-PDFF and MR spectroscopy-PDFF measurements, was evaluated by using Bland-Altman analysis. Precision, defined as the agreement between repeated MR imaging-PDFF measurements, was evaluated by using a linear mixed-effects model, with field strength, imager manufacturer, reconstruction method, and region of interest as random effects. Results Twenty-three studies (1679 participants) were selected for linearity and bias analyses and 11 studies (425 participants) were selected for precision analyses. MR imaging-PDFF was linear with MR spectroscopy-PDFF (R2 = 0.96). Regression slope (0.97; P < .001) and mean Bland-Altman bias (-0.13%; 95% limits of agreement: -3.95%, 3.40%) indicated minimal underestimation by using MR imaging-PDFF. MR imaging-PDFF was precise at the region-of-interest level, with repeatability and reproducibility coefficients of 2.99% and 4.12%, respectively. Field strength, imager manufacturer, and reconstruction method each had minimal effects on reproducibility. Conclusion MR imaging-PDFF has excellent linearity, bias, and precision across different field strengths, imager manufacturers, and reconstruction methods. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 2, 2017.

1 December 2016 in Radiology
Verified
Journal Article
Closed access
ATAndrew T. Trout
Andrew T. Trout
SSSuraj Dilip Serai
Suraj Dilip Serai
AMAlana D. Mahley
Alana D. Mahley
HWHui Wang
Hui Wang
YZYue Zhang
Yue Zhang
JDJonathan R. Dillman
Jonathan R. Dillman
MR elastography is a reliable imaging method for assessing liver stiffness, although variability exists across MR imaging system manufacturers, field strengths, and pulse sequences. Purpose To prospectively assess agreement and repeatability of magnetic resonance (MR) elastography liver stiffness measurements across imager manufacturers, field strengths, and pulse sequences. Materials and Methods This prospective cross-sectional study was approved by the institutional review board; informed consent was obtained from all subjects. On the basis of an a priori power calculation, 24 volunteer adult subjects underwent MR elastography with four MR imaging systems (two vendors) and multiple pulse sequences (two-dimensional [2D] gradient-echo [GRE] imaging, 2D spin-echo [SE] echo-planar imaging, and three-dimensional [3D] SE echo-planar imaging). Each sequence was performed twice in each patient with each imaging system. Intraclass correlation coefficients (ICCs) were used to assess agreement and repeatability. P < .05 was considered indicative of a statistically significant difference. Results Pairwise ICCs were 0.67–0.82 and 0.62–0.83 for agreement between pulse sequences across manufactur...

1 October 2017 in Radiology
Verified
Journal Article
Closed access
SSSuraj Dilip Serai
Suraj Dilip Serai
NONancy A. Obuchowski
Nancy A. Obuchowski
SVSudhakar Venkatesh
Sudhakar Venkatesh
CSClaude B. Sirlin
Claude B. Sirlin
FMFrank H. Miller
Frank H. Miller
RERichard L. Ehman
Richard L. Ehman
Our estimated meta-analysis summary repeatability coefficient for MR elastography was 22% (95% confidence interval: 16.1%, 28.2%); hence, assuming no change in MR elastography hardware and software... Purpose To perform a meta-analysis to generate an estimate of the repeatability coefficient (RC) for magnetic resonance (MR) elastography of the liver. Materials and Methods A systematic search of ...

1 June 2018 in Radiology
Verified
Journal Article
Closed access
ATAndrew T. Trout
Andrew T. Trout
RSRachel M. Sheridan
Rachel M. Sheridan
SSSuraj Dilip Serai
Suraj Dilip Serai
SXStavra A. Xanthakos
Stavra A. Xanthakos
WSWeizhe Su
Weizhe Su
DWDaniel B. Wallihan
Daniel B. Wallihan
MR elastography provides moderate test performance for distinguishing stage 0–1 fibrosis from stage 2 or higher fibrosis in pediatric patients with liver disease. PurposeTo assess the diagnostic performance of magnetic resonance (MR) elastography–derived liver stiffness to detect liver fibrosis in a pediatric and young adult population with a spectrum of liver diseases.Materials and MethodsThis retrospective study included patients younger than 21 years of age who underwent MR elastography and liver biopsy within 3 months of one another between January 2012 and September 2016 for indications other than liver transplantation or Fontan palliation of congenital heart disease. MR elastography examinations were reprocessed by a single observer, blinded to pathologic findings. Pathology specimens were reviewed by a single pathologist who scored steatosis (lipid in ≥ 5% of hepatocytes) and staged fibrosis. Receiver operating characteristic (ROC) curves were used to assess diagnostic performance.ResultsA total of 86 patients, 49 (57%) male with a median age of 14.2 years (range, 0.3–20.6 years), were included. Fifty-one patients (59.3%) had Ludwig stage 2 or higher fibrosi...


1 July 2017 in Radiology
Verified
Journal Article
Closed access
SSSuraj Dilip Serai
Suraj Dilip Serai
JDJonathan R. Dillman
Jonathan R. Dillman
ATAndrew T. Trout
Andrew T. Trout
Estimation of proton density fat fraction at hepatic MR imaging by using mDIXON Quant and IDEAL IQ is highly reproducible across imaging platforms (including different manufacturers and field strengths), with only minimal average bias that in most instances is likely clinically irrelevant. Purpose To determine the agreement of proton density fat fraction (PDFF) measurements obtained with hepatic magnetic resonance (MR) imaging among readers, imager manufacturers, and field strengths. Materials and Methods This HIPAA-compliant study was approved by the institutional review board. After providing informed consent, 24 adult volunteers underwent imaging with one 1.5-T MR unit (Ingenia; Philips Healthcare, Best, the Netherlands) and two different 3.0-T units (750 W [GE Healthcare, Waukesha, Wis] and Ingenia) on the same day to estimate hepatic PDFF. A single-breath-hold multipoint Dixon-based acquisition was performed with commercially available pulse sequences provided by the MR imager manufacturers (mDIXON Quant [Philips Healthcare], IDEAL IQ [GE Healthcare]). Five readers placed one large region of interest, inclusive of as much liver parenchyma as possible in the right lobe while avoiding large vessels, on imager-generated parametric maps to measure hepatic PDFF. Two-way single-measure intra...