Fei Li

Dr. Fei Li

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2019 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
FLFei Li
Fei Li
ZHZhi-Wen Huang
Zhi-Wen Huang
XWXiaofei Wang
Xiaofei Wang
HXHui-Wen Xu
Hui-Wen Xu
HYHua Yu
Hua Yu
WLWei Lei
Wei Lei
Background: To promote the utilization of pulmonary function tests (PFT) through analyzing the data of PFT during the past seven years in one large teaching hospital in China. Methods: Through a retrospective analysis, the allocation of full-time staff in PFT room, the demographic characteristics of patients, cost-effectiveness of PFT, positive rate and failure rate of PFT, adverse events were analyzed. Results: 1) From 2012 to 2018, the numbers of PFT showed the trend of escalation year by year. The proportion of patients receiving PFT rose from 29.0/10,000 in 2012 to 34.7/10,000 in 2018. The best allocation of PFT room was 20–25/ person / day. 2) The number of PFT provided by Department of Pulmonary and Critical Care Medicine (PCCM) accounted for 97.2, 97.1, 97.3, 97.8, 97.8, 98.0, and 98.2% of the total cases of outpatient PFT in the same year. The top three departments in the inpatient department were Department of Thoracic Surgery, Department of General Surgery, and Department of Urinary Surgery, the total cases of PFT in these three departments accounted for 65.1, 64.4, 62.1, 63.5, 62.4, 65.3 and 69.1% of the total cases of inpatient PFT in the same year. 3) Data from 2018 showed that the revenue from PFT was about 3.7 million Chinese Yuan, and that the salary of personnel and expenditure on machine maintenance and wear were about 800,000 Chinese Yuan. 4) 58.2% of the patients who had undergone PFT had ventilatory dysfunction. 5) The average failure rate of PFT in the past seven years was 1.91%. 6) The main adverse events of PFT examination were dizziness, amaurosis, limb numbness, lip numbness and falls. The incidence rates were 0.49, 0.42, 0.41, 0.39, 0.44, 0.48, and 0.45% respectively, with an average of 0.44%. Conclusions: The number of PFT showed an upward trend in the past seven years, and the optimal staffing of PFT room was 20–25 cases per person per day. The positive rate of pulmonary dysfunction was 58.2%. The failure rate of PFT and the incidence of adverse events were very low, suggesting it is a simple and safe clinical examination. It’s worthy of further popularization and promotion.

20 January 2025 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
JMJiao Min
Jiao Min
XTXiaomiao Tang
Xiaomiao Tang
DZDi Zhang
Di Zhang
JYJin Yang
Jin Yang
FLFei Li
Fei Li
WLWei Lei
Wei Lei
Background: Cough variant asthma (CVA) is a specific type of asthma characterized by chronic cough as the sole or predominant symptom. Accurate diagnosis is crucial for effective treatment, yet bronchial provocation test is not always feasible in clinical settings. To identify independent predictors of CVA diagnosis, we developed a nomogram for predicting CVA. Univariate and multivariate logistic regression analyses were employed to construct the model, and the accuracy and consistency of the prediction model were subsequently validated. Methods: We conducted a retrospective review of clinical data from 241 outpatients with chronic cough (≥ 8 weeks) who underwent bronchial provocation test at our hospital between January 2018 and December 2021. Patients were categorized into CVA group and Non-CVA group based on diagnostic criteria. Univariate analysis (chi-square and t-tests) was performed, followed by multivariate logistic regression to identify independent predictors. A nomogram was constructed using these predictors and validated using Bootstrap resampling (B = 200) to calculate the C-index. Additionally, receiver operating characteristic (ROC) curve analysis and decision curve analysis (DCA) were employed to assess the model's accuracy. Results: Of the 241 outpatients, 156 (64.7%) were diagnosed with CVA. Multivariate analysis identified several independent predictors of CVA, including cough triggered by cold air (OR = 12.493, P = 0.019), exposure to pungent odors (OR = 3.969, P = 0.002), cough phasing (OR = 4.515, P < 0.001), history of allergic rhinitis (OR = 3.231, P = 0.018), and the percentage of the predicted value of maximum mid-expiratory flow (MMEF%pred) (OR = 0.981, P = 0.039) were independent predictors of CVA. The nomogram demonstrated good discrimination (AUC = 0.829) and calibration, with a sensitivity of 75.3% and specificity of 77.6% at the optimal cutoff. The C-index was 0.920, indicating excellent model performance. Conclusions: We successfully developed and validated a user-friendly nomogram that accurately predicted CVA diagnosis based on clinical characteristics and pulmonary function test. This nomogram model could assist clinicians in diagnosing CVA, especially in patients without bronchial provocation test or with contraindications to bronchial provocation test.