Zhi-Wen Huang

Zhi-Wen Huang

Auto-generated profile, based on publicly available information

Zhi-Wen Huang

Department of Respiratory Medicine, Affiliated Renhe Hospital/Second Clinical Medical College of China Three Gorges University, Yichang, Hubei, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2019 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
FLFei Li
Fei Li
ZHZhi-Wen Huang
Zhi-Wen Huang
XWXiaofei Wang
Xiaofei Wang
HXHui-Wen Xu
Hui-Wen Xu
HYHua Yu
Hua Yu
WLWei Lei
Wei Lei
Background: To promote the utilization of pulmonary function tests (PFT) through analyzing the data of PFT during the past seven years in one large teaching hospital in China. Methods: Through a retrospective analysis, the allocation of full-time staff in PFT room, the demographic characteristics of patients, cost-effectiveness of PFT, positive rate and failure rate of PFT, adverse events were analyzed. Results: 1) From 2012 to 2018, the numbers of PFT showed the trend of escalation year by year. The proportion of patients receiving PFT rose from 29.0/10,000 in 2012 to 34.7/10,000 in 2018. The best allocation of PFT room was 20–25/ person / day. 2) The number of PFT provided by Department of Pulmonary and Critical Care Medicine (PCCM) accounted for 97.2, 97.1, 97.3, 97.8, 97.8, 98.0, and 98.2% of the total cases of outpatient PFT in the same year. The top three departments in the inpatient department were Department of Thoracic Surgery, Department of General Surgery, and Department of Urinary Surgery, the total cases of PFT in these three departments accounted for 65.1, 64.4, 62.1, 63.5, 62.4, 65.3 and 69.1% of the total cases of inpatient PFT in the same year. 3) Data from 2018 showed that the revenue from PFT was about 3.7 million Chinese Yuan, and that the salary of personnel and expenditure on machine maintenance and wear were about 800,000 Chinese Yuan. 4) 58.2% of the patients who had undergone PFT had ventilatory dysfunction. 5) The average failure rate of PFT in the past seven years was 1.91%. 6) The main adverse events of PFT examination were dizziness, amaurosis, limb numbness, lip numbness and falls. The incidence rates were 0.49, 0.42, 0.41, 0.39, 0.44, 0.48, and 0.45% respectively, with an average of 0.44%. Conclusions: The number of PFT showed an upward trend in the past seven years, and the optimal staffing of PFT room was 20–25 cases per person per day. The positive rate of pulmonary dysfunction was 58.2%. The failure rate of PFT and the incidence of adverse events were very low, suggesting it is a simple and safe clinical examination. It’s worthy of further popularization and promotion.

10 March 2025 in Physiological Research
Verified
Journal Article
Open access
LLL Liu
L Liu
MXM Xu
M Xu
JWJ Wang
J Wang
YHY Hu
Y Hu
ZHZ Huang
Z Huang
A common opioid analgesic for cancer pain and, to a lesser extent, non-cancer pain, is hydromorphone (HM). Oral formulations as well as subcutaneous, intravenous, and other routes are frequently used for its administration. Its pharmacokinetics and pharmacodynamics have also been extensively researched. This article examines the pharmacological properties of hydromorphone and the development of its use both domestically and internationally with the goal of serving as a reference for the sensible clinical use of this medication.