Michael Bottlang

Dr. Michael Bottlang


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2010 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MBMichael Bottlang
Michael Bottlang
MLMaren Lesser
Maren Lesser
JKJulia Koerber
Julia Koerber
JDJosef Doornink
Josef Doornink
BRBrigitte von Rechenberg
Brigitte von Rechenberg
JMJ. Lawrence Marsh
J. Lawrence Marsh
Background:Locked bridge plating relies on secondary bone healing, which requires interfragmentary motion for callus formation. This study evaluated healing of fractures stabilized with a locked plating construct and a far cortical locking construct, which is a modified locked plating approach that

1 December 2010 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MBMichael Bottlang
Michael Bottlang
JDJosef Doornink
Josef Doornink
TLTrevor J. Lujan
Trevor J. Lujan
DFDaniel C. Fitzpatrick
Daniel C. Fitzpatrick
JMJ. Lawrence Marsh
J. Lawrence Marsh
SMSteven M. Madey
Steven M. Madey

1 January 2002 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MBMichael Bottlang
Michael Bottlang
JKJames C. Krieg
James C. Krieg
MMMarcus Mohr
Marcus Mohr
TSTamara S. Simpson
Tamara S. Simpson
SMSteven M. Madey
Steven M. Madey

1 February 2011 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
MBMichael Bottlang
Michael Bottlang
FFFlorian Feist
Florian Feist
The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

1 February 2009 in Clinical Biomechanics
Verified
Journal Article
Closed access
DFDaniel C. Fitzpatrick
Daniel C. Fitzpatrick
JDJosef Doornink
Josef Doornink
SMSteve Madey
Steve Madey
MBMichael Bottlang
Michael Bottlang

16 March 2016 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MBMichael Bottlang
Michael Bottlang
STStanley Tsai
Stanley Tsai
EBEmily K. Bliven
Emily K. Bliven
BRBrigitte von Rechenberg
Brigitte von Rechenberg
KKKarina Klein
Karina Klein
SMSteven M. Madey
Steven M. Madey
Background: Axial dynamization of fractures can promote healing, and overly stiff fixation can suppress healing. A novel technology, termed active plating, provides controlled axial dynamization by the elastic suspension of locking holes within the plate. This prospective, controlled animal study evaluated the effect of active plates on fracture-healing in an established ovine osteotomy model. We hypothesized that symmetric axial dynamization with active plates stimulates circumferential callus and delivers faster and stronger healing relative to standard locking plates. Methods: Twelve sheep were randomly assigned to receive a standard locking plate or an active locking plate for stabilization of a 3-mm tibial osteotomy gap. The only difference between plates was that locking holes of active plates were elastically suspended, allowing up to 1.5 mm of axial motion at the fracture. Fracture-healing was analyzed weekly on radiographs. After sacrifice at nine weeks postoperatively, callus volume and distribution were assessed by computed tomography. Finally, to determine their strength, healed tibiae and contralateral tibiae were tested in torsion until failure. Results: At each follow-up, the active locking plate group had more callus (p < 0.001) than the standard locking plate group. At postoperative week 6, all active locking plate group specimens had bridging callus at the three visible cortices. In standard locking plate group specimens, only 50% of these cortices had bridged. Computed tomography demonstrated that all active locking plate group specimens and one of the six standard locking plate group specimens had developed circumferential callus. Torsion tests after plate removal demonstrated that active locking plate group specimens recovered 81% of their native strength and were 399% stronger than standard locking plate group specimens (p < 0.001), which had recovered only 17% of their native strength. All active locking plate group specimens failed by spiral fracture outside the callus zone, but standard locking plate group specimens fractured through the osteotomy gap. Conclusions: Symmetric axial dynamization with active locking plates stimulates circumferential callus and yields faster and stronger healing than standard locking plates. Clinical Relevance: The stimulatory effect of controlled motion on fracture-healing by active locking plates has the potential to reduce healing complications and to shorten the time to return to function.