Yasmeen Ahmed

Dr. Yasmeen Ahmed


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2023 in Microchemical Journal
Verified
Journal Article
Closed access
YAYasmeen Ahmed
Yasmeen Ahmed
Miriam AyadMiriam Ayad
Miriam Ayad
LHLobna A. Hussein
Lobna A. Hussein
Nermine FaresNermine Fares
Nermine Fares

23 November 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
YAYasmeen Ahmed
Yasmeen Ahmed
SOSherif Okeil
Sherif Okeil
Miriam AyadMiriam Ayad
Miriam Ayad
LHLobna A. Hussein
Lobna A. Hussein
Nermine FaresNermine Fares
Nermine Fares
Monitoring fungicide residues in orange fruits is vital, as fungicides for orange cultivation are increasingly used to prevent yield loss. At the same time, increasing restrictions are added by regulatory organizations. For facile on-site monitoring of the fungicide carbendazim (MBC), five ion-selective potentiometric sensors are proposed and compared. The first two sensors were prepared with a precipitation-based technique using molybdate (sensor 1) and tetraphenylborate (TPB) (sensor 2), respectively. Furthermore, two ionophore-based sensors were prepared using β-cyclodextrin as ionophore together with TPB (sensor 3) and tetrakis(4-chlorophenyl)borate (TpClPB) (sensor 4) as ion-exchanger. Further incorporation of multi-walled carbon nanotubes (MWCNTs) between the graphite rod and the sensing membrane of sensor 4 (sensor 5) further improved the stability and significantly lowered the limit of detection (LOD). Their performance was evaluated according to IUPAC recommendations, revealing linear response in the concentration range 1 × 10−4–1 × 10−2 M, 1 × 10−5–1 × 10−2 M, 1 × 10−5–1 × 10−3 M, 1 × 10−6–1 × 10−3 M, and 1 × 10−7–1 × 10−3 M with a Nernstian slope of 54.56, 55.48, 56.00, 56.85, and 57.34 mV/decade, respectively. The LOD values for the five sensors were found to be 7.92 × 10−5, 9.98 × 10−6, 9.72 × 10−6, 9.61 × 10−7, and 9.57 × 10−8 M, respectively. The developed potentiometric sensors were successfully applied to determine the residue and degradation rate of MBC in orange samples. After the researched fungicide was applied to the orange trees, the preharvest interval (PHI) could be calculated based on the MBC degradation kinetics determined in the tested orange samples.

10 March 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
YAYasmeen Ahmed
Yasmeen Ahmed
MAMiriam F. Ayad
Miriam F. Ayad
LHLobna A. Hussein
Lobna A. Hussein
Nermine FaresNermine Fares
Nermine Fares
The economic viability of Egyptian potato exports relies heavily on compliance with strict international regulations regarding pesticide residues. This study establishes a robust, sensitive, green, and cost-effective High-Performance Liquid Chromatographic method with Diode Array Detection to quantify six multiclass pesticide residues simultaneously: Thiamethoxam, Cymoxanil, Metalaxyl, Fludioxonil, Imazalil, and Famoxadone in potato matrix. To overcome matrix complexity, a comprehensive optimization of sample preparation was conducted, critically comparing Liquid-Liquid Extraction (LLE), QuEChERS, and Solid Phase Extraction. Results demonstrated that LLE, utilizing a dichloromethane: acetone (50: 50, v/v) mixture with salt-assisted partitioning (1.0 g anhydrous magnesium sulfate and 0.5 g sodium chloride), offered superior extraction efficiency (recoveries 75.84%–87.92%). A C18 column was used to resolve the analytes within 12 minutes, using an acetonitrile-water gradient. Method validation per SANTE and ICH guidelines exhibited high linearity (R2 >0.999), accuracy, and precision (mean recoveries 99.02%–100.67% with average %RSD < 1.22%). It was then successfully applied to market sample monitoring. Furthermore, a dissipation study indicated that the residues follow first-order degradation kinetics in field conditions. Additionally, the impact of household processing was evaluated, showing that boiling potatoes for 30 minutes effectively reduces residue concentrations below Maximum Residue Limits, ensuring consumer safety. This optimized method provides a reliable analytical tool for routine quality control in import-export surveillance. Additionally, the Analytical GREEnness with score 0.69 and Green Analytical Procedure Index metrics were used to evaluate the environmental impact of the proposed method.