Because river flooding and urban inundation due to extreme rainfall cause the severe damages on the infrastructure, it is necessary to develop an accurate prediction technique and to overcome the disasters. In this study, numerical simulation method was applied to predict urban inundation area with appropriate assumptions and hydrological data in the Lower Var valley region in France. The application site is located in the southeast of France and also geometrically complex with several hydraulic structures, such as weir and bridge piers from the mainstream of a river to the Mediterranean Sea. With complex geometrical consideration, numerical modelling of inundation was conducted separately with two steps. Firstly, the whole area of river reach with the urban area was simulated and analyzed. From the results, the smaller urbanized area was specified with consideration of the capacity of inundation. Two-dimensional hydrodynamic model, MIKE 21 FM (flow model) is applicable to simulations of river hydraulics and flood inundation including the urbanized properties. Upstream discharges for the boundary conditions were set up with based on the Gumbel distribution and SCHADEX method. From the numerical simulation, inundation area and river flow variation were analyzed and compared with respect to the upstream discharge scenarios. Furthermore, the effect of computational mesh resolution was analyzed with the urban model. Calculated flooded areas from the simulation results of the whole area model and urbanized models were compared and verified as a newly proposed and applied procedure of inundation analysis in the riverine area.
Local scour occurs around hydraulic structures such as piers, bed protections, and dikes. In this study, the turbulent flow around a scour hole downstream of a fixed bed protection was investigated. Numerical modeling with OpenFOAM was applied to compute the flow velocity and turbulent kinetic energy with respect to flow conditions by changing water depth. A proper computational grid size and time step for simulations are suggested. Three typical turbulent models, , , and , were considered for simulating the flow around a scour hole. The performances of the three models were evaluated by comparing them with numerical and laboratory experimental results. Mean flow velocity profiles computed by the three turbulent schemes are generally in good agreement with laboratory measurements. However, has a limitation in simulating reversal flow in the scour hole, and the model does not predict turbulent kinetic energy well near the bottom. Thus, this study found that the most suitable turbulent model for simulating flow around a scour hole downstream of a fixed bed protection is the model.
A pump station is a crucial flood control facility for mitigating inundation of urban lowland areas. Securing a site to increase the capacity of a pump station or to maximize the discharge capacity of the pump sump in an urban area is difficult because of various limitations. Moreover, adding a facility to improve the pump capacity of a pump station may affect flow characteristics, e.g., unexpected increases in flow velocity and vorticity, and cause severe problems in pump station operation. To solve those problems, anti-vortex devices (AVDs) have been developed and adopted according to the appropriate design standards. The Korean design criteria for AVDs are based on experience and the standards of other countries because of the lack of adequate data on AVDs. In this study, flow in the sump was numerically simulated at various AVD heights to obtain data for improving the design and efficiency of a pump station. Consequently, the appropriate height for the AVD and changes in the flow pattern and vortex in the pump sump were determined and compared with 12 cases of inflow conditions with respect to the vertical location.
Considering fundamental hydraulics, fluid dynamics, and experimental analysis should be analyzed simultaneously with mathematical methods due to the effects of hydraulic properties such as meandering form, sediment, and so on. In this research, to reveal the effects of hydraulic characteristics and longitudinal and transverse coefficients based on the two-dimensional advection-dispersion equation, a laboratory experimental channel has been conducted and analyzed. Additionally, results of experiments have been compared with horizontal two dimensional distributions of flow velocity and concentration fields with respect to the water depth and inlet discharge using two-dimensional depth-averaged numerical models based on FEM (Finite Element Method). SMS and RAMS have been applied with the same experimental conditions and compared. From the analysis of velocity profiles, primary and secondary flows have been visualized. Also the result of pollutant clouds illustrated from the results of tracer tests with an instantaneous and centered injection of solute transport, separation, superposition and stagnation could be deduced outwards of two meandering sections. And same types of characteristics of velocity and pollutant transport could be defined with two-dimensional numerical models.
30 August 2016 in KSCE Journal of Civil Engineering
Pump stations are very important flood control facilities in that they are designed to mitigate inundation in urban lowland areas. In urban areas, however, it is often difficult to acquire the land needed to increase the capacity of a pump station. Thus, the discharge capacity should be maximized despite these restricted conditions. The installation of a new pump with a larger capacity would be one way of increasing the capacity of a pump station. However, the addition of facilities could affect the flow characteristics, such as increasing the flow velocity and vorticity, thus causing severe problems with the operation of the pump. To overcome those problems, an Anti-vortex Device (AVD) can be applied. In Korea, the design of a pump station demands that engineers refer to advanced design criteria derived in other countries, owing to the lack of appropriate domestic design standards. In addition, the Korean design criteria for an AVD are based on experience, as there is insufficient available data. In this study, a numerical simulation was applied to simulate the swirl flow in a sump with various AVD heights to derive information that can be applied to studies aimed at improving the design and efficiency of pump station.
Local scour at the downstream of the river bed protection is one of the most important parameters for the design criteria and sustainable management of the hydraulic structures. Previously, various researches on its process in the equilibrium state have been suggested with experimental and numerical approaches. In this study, relatively long-term laboratory experiments of local scouring at the downstream of fixed bed in an open channel were conducted with mono-granular sediment bed and analyzed about maximum scour depth and its temporal development. In particular, we conducted experiments with relatively low Froude number (less than 0.5) and their duration of tests was exceeded over 700 hours. We modified the relationship between the dimensionless time and length scales of the maximum scour depth of the local scour hole based on the turbulent shear layer thickness. A new functional relationship between dominant factors and the maximum scour depth in the equilibrium state were suggested and compared with previously suggested formula. Also, from the results by nonlinear regression, Froude number was founded as a dominant factor on the prediction of equilibrium maximum scour depth.