Yurong Wang

Dr. Yurong Wang


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2025 in Chaos, Solitons & Fractals
Verified
Journal Article
Closed access
HZHongqiao Zhang
Hongqiao Zhang
ZLZhaohui Li
Zhaohui Li
YWYurong Wang
Yurong Wang
CHChao Hang
Chao Hang
GWGuang Wu
Guang Wu

29 July 2024 in Photonics
Verified
Journal Article
Open access
PDF file
QHQI Huiyu
QI Huiyu
ZLZhaohui Li
Zhaohui Li
YWYurong Wang
Yurong Wang
XCXiuliang Chen
Xiuliang Chen
HPHaifeng Pan
Haifeng Pan
GWGuang Wu
Guang Wu
Synchronous laser beam scanning is a common technique used in single-photon imaging where the spatial resolution is primarily determined by the beam divergence angle. In this context, Bessel beams have been investigated as they can overcome the diffraction limit associated with traditional Gaussian beams. Notably, the central spot of a Bessel beam retains its size almost unchanged within a non-diffractive distance. However, the presence of sidelobes in the Bessel beam can negatively impact spatial resolution. To address this challenge, we have developed a single-photon imaging system with high-depth resolution, which allows for the suppression of echo photons from the sidelobe light in the depth image, particularly when their flight time differs from that of the central spot. In our LiDAR setup, we successfully achieved high-resolution scanning imaging with a spatial resolution of approximately 0.5 mm while also demonstrating a high-depth resolution of 12 mm.

31 October 2024 in Photonics
Verified
Journal Article
Open access
PDF file
XZXinyi Zhu
Xinyi Zhu
YWYurong Wang
Yurong Wang
ZLZhaohui Li
Zhaohui Li
雪李雪 李
雪 李
GWGuang Wu
Guang Wu
The two-way laser time transfer technology, based on single-photon detection, is among the techniques requiring the least weight and power consumption for ultra-long-distance clock synchronization. It holds promise as the most viable technology for high-accuracy inter-satellite clock synchronization, particularly for small satellites that are highly sensitive to weight and power consumption. In this study, we analyze laser time transfer in fast-moving platforms and find that not only does the relative motion speed between platforms significantly impact the clock offset measurement, but also the components of each platform’s relative motion velocity are critical. We introduce a lightweight scenario for laser time transfer, capable of achieving high-precision and high-accuracy interstellar clock offset measurements within a 5000 km range using high repetition rate microchip lasers and single-pixel single-photon detectors. With a speed accuracy of ±0.06 m/s, the precision of clock offset measurement surpasses 3 ps at full width at half maximum (FWHM), making it suitable for high-speed and high-precision clock synchronization between near-Earth satellites.

1 October 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
雪李雪 李
雪 李
YWYurong Wang
Yurong Wang
ZLZhaohui Li
Zhaohui Li
HPHaifeng Pan
Haifeng Pan
XCXiuliang Chen
Xiuliang Chen
GWGuang Wu
Guang Wu
In long-distance laser time transfer, such as satellite-to-satellite and satellite-to-ground, the accuracy of flight time measurement for photon pulses is significantly compromised by the time walk phenomenon, stemming from variations of the incident photon numbers. In this paper, we propose a single-photon detection method, which is adaptive to the photon number, and passively compensates for the time walk effect. This method utilizes a fiber ring to divide an incident photon pulse into a series of photon pulse trains, with each pulse in the train separated by equal time intervals and subject to equal attenuation. The last detected photon pulse in the pulse train can always be attenuated to a single-photon level sufficient to render the time walk effect negligible. The experimental results demonstrate that the proposed method effectively mitigates the time walk effect across a range of average photon numbers, spanning from 1 to 100. It provides high-precision single-photon detection for laser time transfer in complex and variable environments.

15 September 2025 in Photonics
Verified
Journal Article
Open access
PDF file
MHMengting He
Mengting He
YWYurong Wang
Yurong Wang
JLJunjie Lin
Junjie Lin
CYCao Yujing
Cao Yujing
Botao WuBotao Wu
Botao Wu
E. WuE. Wu
E. Wu
Silicon carbide (SiC) is a representative wideband-gap semiconductor with remarkable properties, such as high breakdown field strength, high thermal conductivity, and high carrier saturation mobility. Meanwhile, single-photon emitters (SPEs) in SiC have attracted considerable attention owing to their excellent fluorescence performances and promising applications in the quantum realm. Here, we conducted a systematic experimental investigation into the temperature-dependent characteristics of the SPEs in cubic silicon carbide (3C-SiC) crystal. Over a temperature span from 293 K to 373 K, the variations in fluorescence intensity, fluorescence lifetime, fluorescence spectra, polarization characteristics, and second-order autocorrelation function g2(τ) were examined. The fluorescence properties of defects showed extraordinary stabilization even when the temperature was raised to 373 K. Based on the above characteristics and combined with the excellent properties of SiC materials, this study provides strong evidence that SPEs in 3C-SiC can serve as information carriers capable of operating stably under high-temperature conditions.

9 May 2026 in Photonics
Verified
Journal Article
Open access
PDF file
HZHanping Zhang
Hanping Zhang
XZXinyi Zhu
Xinyi Zhu
YWYurong Wang
Yurong Wang
E. WuE. Wu
E. Wu
GWGuang Wu
Guang Wu
In single-photon detection, dark count represents a critical limitation, particularly for high-sensitivity applications. Conventional estimators based on the binary per-gate observable become ill-conditioned when the dark count per-gate probability approaches unity, a situation common in first-photon-gated detectors with extended gate width. This work proposes a complementary characterization method based on the statistical expectation of dark count arrival time. This approach captures the cumulative temporal behavior of dark count across multiple gating cycles, providing a more accurate estimation of the dark count rate. Both numerical simulations and experimental results demonstrate that our method yields significantly more stable and precise measurements compared to the conventional approach. Specifically, while the conventional method introduces errors up to ±4% at larger gate widths, the proposed timing-based method converges to a significantly lower residual error of approximately −0.17%. These findings offer a promising route to enhance the characterization and performance of first-photon-gated single-photon detectors in practical applications.