Momona Yamagami

Dr. Momona Yamagami

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2023
Verified
Conference Paper
Open access
KGKate S Glazko
Kate S Glazko
MYMomona Yamagami
Momona Yamagami
ADAashaka Desai
Aashaka Desai
KMKelly Avery Mack
Kelly Avery Mack
VPVenkatesh Potluri
Venkatesh Potluri
JMJennifer Mankoff
Jennifer Mankoff
With the recent rapid rise in Generative Artificial Intelligence (GAI) tools, it is imperative that we understand their impact on people with disabilities, both positive and negative. However, although we know that AI in general poses both risks and opportunities for people with disabilities, little is known specifically about GAI in particular. To address this, we conducted a three-month autoethnography of our use of GAI to meet personal and professional needs as a team of researchers with and without disabilities. Our findings demonstrate a wide variety of potential accessibility-related uses for GAI while also highlighting concerns around verifiability, training data, ableism, and false promises.

20 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MYMomona Yamagami
Momona Yamagami
KPKeshia M. Peters
Keshia M. Peters
IMIvana Milovanovic
Ivana Milovanovic
IKIrene Kuang
Irene Kuang
ZYZeyu Yang
Zeyu Yang
KSKatherine M. Steele
Katherine M. Steele
Commercially available electrodes can only provide quality surface electromyography (sEMG) measurements for a limited duration due to user discomfort and signal degradation, but in many applications, collecting sEMG data for a full day or longer is desirable to enhance clinical care. Few studies for long-term sEMG have assessed signal quality of electrodes using clinically relevant tests. The goal of this research was to evaluate flexible, gold-based epidermal sensor system (ESS) electrodes for long-term sEMG recordings. We collected sEMG and impedance data from eight subjects from ESS and standard clinical electrodes on upper extremity muscles during maximum voluntary isometric contraction tests, dynamic range of motion tests, the Jebsen Taylor Hand Function Test, and the Box & Block Test. Four additional subjects were recruited to test the stability of ESS signals over four days. Signals from the ESS and traditional electrodes were strongly correlated across tasks. Measures of signal quality, such as signal-to-noise ratio and signal-to-motion ratio, were also similar for both electrodes. Over the four-day trial, no significant decrease in signal quality was observed in the ESS electrodes, suggesting that thin, flexible electrodes may provide a robust tool that does not inhibit movement or irritate the skin for long-term measurements of muscle activity in rehabilitation and other applications.

23 April 2020
Verified
Conference Paper
Open access
MYMomona Yamagami
Momona Yamagami
KSKatherine M. Steele
Katherine M. Steele
SBSamuel A. Burden
Samuel A. Burden
Manual device interaction requires precise coordination which may be difficult for users with motor impairments. Muscle interfaces provide alternative interaction methods that may enhance performance, but have not yet been evaluated for simple (eg. mouse tracking) and complex (eg. driving) continuous tasks. Control theory enables us to probe continuous task performance by separating user input into intent and error correction to quantify how motor impairments impact device interaction. We compared the effectiveness of a manual versus a muscle interface for eleven users without and three users with motor impairments performing continuous tasks. Both user groups preferred and performed better with the muscle versus the manual interface for the complex continuous task. These results suggest muscle interfaces and algorithms that can detect and augment user intent may be especially useful for future design of interfaces for continuous tasks.

8 July 2022 in ACM Transactions on Accessible Computing
Verified
Journal Article
Open access
MYMomona Yamagami
Momona Yamagami
SJSasa Junuzovic
Sasa Junuzovic
MGMar Gonzalez-Franco
Mar Gonzalez-Franco
EOEyal Ofek
Eyal Ofek
ECEdward Cutrell
Edward Cutrell
MMMartez E. Mott
Martez E. Mott
Virtual Reality (VR) applications often require users to perform actions with two hands when performing tasks and interacting with objects in virtual environments. Although bimanual interactions in VR can resemble real-world interactions—thus increasing realism and improving immersion—they can also pose significant accessibility challenges to people with limited mobility, such as for people who have full use of only one hand. An opportunity exists to create accessible techniques that take advantage of users’ abilities, but designers currently lack structured tools to consider alternative approaches. To begin filling this gap, we propose Two-In-One, a design space that facilitates the creation of accessible methods for bimanual interactions in VR from unimanual input. Our design space comprises two dimensions, bimanual interactions and computer assistance, and we provide a detailed examination of issues to consider when creating new unimanual input techniques that map to bimanual interactions in VR. We used our design space to create three interaction techniques that we subsequently implemented for a subset of bimanual interactions and received user feedback through a video elicitation study with 17 people with limited mobility. Our findings explore complex tradeoffs associated with autonomy and agency and highlight the need for additional settings and methods to make VR accessible to people with limited mobility.

22 October 2023
Verified
Conference Paper
Open access
MYMomona Yamagami
Momona Yamagami
APAlexandra A Portnova-Fahreeva
Alexandra A Portnova-Fahreeva
JKJunhan Kong
Junhan Kong
JWJacob O. Wobbrock
Jacob O. Wobbrock
JMJennifer Mankoff
Jennifer Mankoff
Always-on, upper-body input from sensors like accelerometers, infrared cameras, and electromyography hold promise to enable accessible gesture input for people with upper-body motor impairments. When these sensors are distributed across the person’s body, they can enable the use of varied body parts and gestures for device interaction. Personalized upper-body gestures that enable input from diverse body parts including the head, neck, shoulders, arms, hands and fingers and match the abilities of each user, could be useful for ensuring that gesture systems are accessible. In this work, we characterize the personalized gesture sets designed by 25 participants with upper-body motor impairments and develop design recommendations for upper-body personalized gesture interfaces. We found that the personalized gesture sets that participants designed were highly ability-specific. Even within a specific type of disability, there were significant differences in what muscles participants used to perform upper-body gestures, with some predominantly using shoulder and upper-arm muscles, and others solely using their finger muscles. Eight percent of gestures that participants designed were with their head, neck, and shoulders, rather than their hands and fingers, demonstrating the importance of tracking the whole upper-body. To combat fatigue, participants performed 51% of gestures with their hands resting on or barely coming off of their armrest, highlighting the importance of using sensing mechanisms that are agnostic to the location and orientation of the body. Lastly, participants activated their muscles but did not visibly move during 10% of the gestures, demonstrating the need for using sensors that can sense muscle activations without movement. Both inertial measurement unit (IMU) and electromyography (EMG) wearable sensors proved to be promising sensors to differentiate between personalized gestures. Personalized upper-body gesture interfaces that take advantage of each person’s abilities are critical for enabling accessible upper-body gestures for people with upper-body motor impairments.

8 July 2022 in Prosthetics and Orthotics International
Verified
Journal Article
Closed access
NZNicole L. Zaino
Nicole L. Zaino
MYMomona Yamagami
Momona Yamagami
DGDeborah J. Gaebler-Spira
Deborah J. Gaebler-Spira
KSKatherine M. Steele
Katherine M. Steele
KBKristie F Bjornson
Kristie F Bjornson
HFHeather Feldner
Heather Feldner
Background: Cerebral palsy (CP) affects roughly 3 per 1000 births in the United States and is the most common pediatric developmental motor disability. Ankle foot orthoses (AFOs) are commonly prescribed to provide support and improve function for individuals with CP. Objectives: The study objective was to evaluate the lived experiences of individuals with CP and their caregivers regarding AFO access, use, and priorities. We examined experiences around the perceived purpose of AFOs, provision process, current barriers to use, and ideas for future AFO design. Study design: Secondary qualitative data analysis. Methods: Secondary data analysis was performed on semistructured focus groups that included 68 individuals with CP and 74 caregivers. Of the focus group participants, 66 mentioned AFOs (16 individuals with CP and 50 caregivers). Deidentified transcripts were analyzed using inductive coding, and the codes were consolidated into themes. Results: Four themes emerged: 1) AFO provision is a confusing and lengthy process, 2) participants want more information during AFO provision, 3) AFOs are uncomfortable and difficult to use, and 4) AFOs can benefit mobility and independence. Caregivers and individuals with CP recommended ideas such as 3D printing orthoses and education for caregivers on design choices to improve AFO design and provision. Conclusions: Individuals with CP and their caregivers found the AFO provision process frustrating but highlight that AFOs support mobility and participation. Further opportunities exist to support function and participation of people with CP by streamlining AFO provision processes, creating educational materials, and improving AFO design for comfort and ease of use.