Keshia M. Peters

Keshia M. Peters

Auto-generated profile, based on publicly available information

Keshia M. Peters

Department of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MYMomona Yamagami
Momona Yamagami
KPKeshia M. Peters
Keshia M. Peters
IMIvana Milovanovic
Ivana Milovanovic
IKIrene Kuang
Irene Kuang
ZYZeyu Yang
Zeyu Yang
KSKatherine M. Steele
Katherine M. Steele
Commercially available electrodes can only provide quality surface electromyography (sEMG) measurements for a limited duration due to user discomfort and signal degradation, but in many applications, collecting sEMG data for a full day or longer is desirable to enhance clinical care. Few studies for long-term sEMG have assessed signal quality of electrodes using clinically relevant tests. The goal of this research was to evaluate flexible, gold-based epidermal sensor system (ESS) electrodes for long-term sEMG recordings. We collected sEMG and impedance data from eight subjects from ESS and standard clinical electrodes on upper extremity muscles during maximum voluntary isometric contraction tests, dynamic range of motion tests, the Jebsen Taylor Hand Function Test, and the Box & Block Test. Four additional subjects were recruited to test the stability of ESS signals over four days. Signals from the ESS and traditional electrodes were strongly correlated across tasks. Measures of signal quality, such as signal-to-noise ratio and signal-to-motion ratio, were also similar for both electrodes. Over the four-day trial, no significant decrease in signal quality was observed in the ESS electrodes, suggesting that thin, flexible electrodes may provide a robust tool that does not inhibit movement or irritate the skin for long-term measurements of muscle activity in rehabilitation and other applications.

1 November 2017 in Journal of Biomechanics
Verified
Journal Article
Closed access
HCHwan Choi
Hwan Choi
KPKeshia M. Peters
Keshia M. Peters
MMMichael B. MacConnell
Michael B. MacConnell
KLKatie K. Ly
Katie K. Ly
EEEric S. Eckert
Eric S. Eckert
KSKatherine M. Steele
Katherine M. Steele

16 March 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
YPYing-Chun (Preston) Pan
Ying-Chun (Preston) Pan
BGBrianna Goodwin
Brianna Goodwin
ESEmily Sabelhaus
Emily Sabelhaus
KPKeshia M. Peters
Keshia M. Peters
KBKristie F Bjornson
Kristie F Bjornson
KSKatherine M. Steele
Katherine M. Steele
Background: Accelerometers have become common for evaluating the efficacy of rehabilitation for patients with neurologic disorders. For example, metrics like use ratio (UR) and magnitude ratio (MR) have been shown to differentiate movement patterns of children with cerebral palsy (CP) compared to typically-developing (TD) peers. However, these metrics are calculated from “activity counts” – a measure based on proprietary algorithms that approximate movement duration and intensity from raw accelerometer data. Algorithms used to calculate activity counts vary between devices, limiting comparisons of clinical and research results. The goal of this research was to develop complementary metrics based on raw accelerometer data to analyze arm movement after neurologic injury. Method: We calculated jerk, the derivative of acceleration, to evaluate arm movement from accelerometer data. To complement current measures, we calculated jerk ratio (JR) as the relative jerk magnitude of the dominant (non-paretic) and non-dominant (paretic) arms. We evaluated the JR distribution between arms and calculated the 50th percentile of the JR distribution (JR50). To evaluate these metrics, we analyzed bimanual accelerometry data for five children with hemiplegic CP who underwent Constraint-Induced Movement Therapy (CIMT) and five typically developing (TD) children. We compared JR between the CP and TD cohorts, and to activity count metrics. Results: The JR50 differentiated between the CP and TD cohorts (CP = 0.578 ± 0.041 before CIMT, TD = 0.506 ± 0.026), demonstrating increased reliance on the dominant arm for the CP cohort. Jerk metrics also quantified changes in arm use during and after therapy (e.g., JR50 = 0.378 ± 0.125 during CIMT, 0.591 ± 0.057 after CIMT). The JR was strongly correlated with UR and MR (r = − 0.92, 0.89) for the CP cohort. For the TD cohort, JR50 was repeatable across three data collection periods with an average similarity of 0.945 ± 0.015. Conclusions: Acceleration-derived jerk captured differences in motion between TD and CP cohorts and correlated with activity count metrics. The code for calculating and plotting JR is open-source and available for others to use and build upon. By identifying device-independent metrics that can quantify arm movement in daily life, we hope to facilitate collaboration for rehabilitation research using wearable technologies.

10 May 2021 in Applied System Innovation
Verified
Journal Article
Open access
PDF file
HFHeather Feldner
Heather Feldner
CPChristina Papazian
Christina Papazian
KPKeshia M. Peters
Keshia M. Peters
CCClaire J. Creutzfeldt
Claire J. Creutzfeldt
KSKatherine M. Steele
Katherine M. Steele
Arm recovery varies greatly among stroke survivors. Wearable surface electromyography (sEMG) sensors have been used to track recovery in research; however, sEMG is rarely used within acute and subacute clinical settings. The purpose of this case study was to describe the use of wireless sEMG sensors to examine changes in muscle activity during acute and subacute phases of stroke recovery, and understand the participant’s perceptions of sEMG monitoring. Beginning three days post-stroke, one stroke survivor wore five wireless sEMG sensors on his involved arm for three to four hours, every one to three days. Muscle activity was tracked during routine care in the acute setting through discharge from inpatient rehabilitation. Three- and eight-month follow-up sessions were completed in the community. Activity logs were completed each session, and a semi-structured interview occurred at the final session. The longitudinal monitoring of muscle and movement recovery in the clinic and community was feasible using sEMG sensors. The participant and medical team felt monitoring was unobtrusive, interesting, and motivating for recovery, but desired greater in-session feedback to inform rehabilitation. While barriers in equipment and signal quality still exist, capitalizing on wearable sensing technology in the clinic holds promise for enabling personalized stroke recovery.