Although hysteresis band current control is an easy to implement and robust control method for industrial power electronics converters, it has also some disadvantages like variable and high switching frequency causing high switching losses. In this study, a novel adaptive fuzzy hysteresis band current control system is proposed by making use of fuzzy expressions of both hybrid active power filter (HAPF) current and integral of its harmonic components to reduce the switching losses of three‐phase three‐wire two‐level HAPF. To reach this aim, a relation between switching frequency and integral of filter current harmonic components is formulised and used for defining a fuzzy hysteresis band. Moreover, the magnitude of the instantaneous current switched is also correlated to the switching losses; in this way, its fuzzy expression is also used for defining hysteresis band. Those fuzzy expressions are then utilised to constitute a dynamically changing hysteresis bandwidth. The proposed control system is finally optimised using EMTDC/PSCAD simulation environment and implemented in the field. The implemented HAPF system has been shown to successfully suppress all the interharmonic and harmonic current components produced by a steel melting facility occupying three induction melting furnaces and it has provided around 9% reduction in overall losses.
14 February 2020 in IEEE Transactions on Plasma Science
ASELSAN Inc. has been conducting experimental research on electromagnetic (EM) launch technologies since 2014. First-generation 1-MJ and second-generation 3.25-MJ pulsed power supplies (PPSs) were built and tested with 25 mm x 25 mm square bore EM Launcher-1 (i.e., Elektromanyetik Firlatma Yolu-1: EMFY-1) EM Launcher at an open area test range by ASELSAN. In 2018, ASELSAN built an EM launch laboratory to perform experiments up to 2-MJ muzzle energy. The stored energy of the second-generation PPSs will be increased to 8 MJ, and the new 50 mm x 50 mm square bore EMFY-2 and 50 mm x 75 mm rectangular bore EMFY-3 EM launchers will be used. We present the ASELSAN EM Launch Laboratory and the results of the first EMFY-2 EM launcher shoot fed by 3.25-MJ PPS at the laboratory.
This paper proposes a design methodology for an active power filter (APF) system to suppress the second harmonic subgroup injected by an AC electric arc furnace (EAF) to the utility grid. The APF system is composed of identical parallel units connected to the utility grid via a specially-designed coupling transformer. Each APF converter is a three-phase three-wire two-level voltage source converter (VSC). The number of parallel APF units, coupling transformer MVA rating, and turns ratio are optimized in the view of the ratings of commercially-available high voltage (HV) IGBTs. In this research work, line current waveforms sampled at 25.6-kS/s on the medium voltage (MV) side of a 65-MVA EAF transformer are then used to extract the second harmonic subgroup, 95-, 100-, and 105-Hz current components, by multiple synchronous reference frame (MSRF) analysis, which was previously proposed to decompose EAF current interharmonics and harmonics in real-time. By summing up this digital data of the second harmonic subgroup, the reference current signal for the APF system is produced in real-time. A detailed model of the APF system is then run on EMTDC/PSCAD to follow the produced reference current signal according to hysteresis band control philosophy. The simulation results show that the proposed APF system can successfully suppress the second harmonic subgroup of an AC EAF.
Here, a novel harmonic suppression performance criterion, namely suppression factor (SF), is suggested for the wide‐frequency power filtering equipment. Performances of single‐tuned passive filter, combination of passive filters tuned to various frequencies, shunt active power filter (APF), and a shunt hybrid active power filter (HAPF) topologies have been evaluated considering their SF values over a defined frequency range. Moreover, effect of the control method for the active filtering equipment on SF values is also analysed by comparing both theoretical and the experimental results. The frequency range of harmonics to be suppressed is chosen using the field measurements of Induction melting furnace (IMF) load, one of the most problematic loads in terms of interharmonics, and a field implemented HAPF system is used for the experimental verifications.