Dynamic ventilation has proven effective in enhancing indoor thermal comfort. However, previous studies often expose participants to inconsistent thermal environments, potentially compromising the accuracy of subjective evaluations. To address this limitation, this study implemented dynamic ventilation with fluctuating air velocity in an accurately controlled environmental chamber. Objective measurements of indoor air velocity and air temperature distribution are conducted, and subjective thermal sensation votes are collected under thermally consistent environments among participants. During the experiment, all participants experience similar dynamic thermal environments. The results show that participants experience thermal comfort under dynamic ventilation. Dynamic ventilation enhances convective heat transfer between the human body and the surrounding air and stimulates cutaneous cold receptors. The pronounced cooling effect of dynamic airflow contributes to a reduction in skin temperature on the head, chest, upper arm, forearm, hand, and thigh, with a temperature drop ranging from 1.3% to 2.8%. In addition, dynamic ventilation significantly reduces draft risk, with the proportion of participants reporting a dissatisfied sensation decreasing from 10% to 0%. This study demonstrates the advantages of dynamic ventilation in improving thermal comfort and minimizing draft risk under controlled and uniform environmental conditions for all participants.
Aim: This study aims to develop supply air jet models for split air conditioners. Background: Designing and operating an air conditioning system based on the unique characteristics of the supply air jet is essential to control the draft risk. Motivation: Due to the distinct differences in air supply characteristics of the split air conditioners caused by the intermittent operation and the complex design of supply air outlets, the existing supply air jet models designed for central air conditioning systems are unsuitable for split air conditioners. Significant results: In this study, models for the trajectory position, velocity, and temperature of the supply air jet for split air conditioners are established based on the Abramovich jet theory and Bayesian Markov Chain Monte Carlo (MCMC) algorithm. The effectiveness of the proposed models is demonstrated via comparison with the training dataset from the experimentally validated Computational Fluid Dynamics simulation of a split air conditioner. For the model testing dataset, the RMSEs of trajectory position, velocity, and temperature are 0.01 m, 0.09 m/s, and 0.09 °C, respectively, with a low supply air velocity and 0.01 m, 0.25 m/s, and 0.03 °C with a high supply air velocity. The proposed models of velocity and temperature of the supply air jet are general for various supply air conditions, while coefficients in the trajectory position model of the supply air jet need to be recalibrated with the proposed Bayesian MCMC algorithm for different supply air conditions. The proposed models provide valuable guidance for the operation of split air conditioners.
In high-temperature environments, using airflow systems has been demonstrated to be an effective method of regulating thermal sensation and enhancing thermal comfort. Given the importance of optimizing airflow selection strategies, the impact of different airflow forms on thermal comfort is a topic worthy of consideration. This study aimed to compare and analyze thermal comfort under three distinct airflow conditions: constant mechanical wind, sinusoidal wind and simulated natural wind. The experimental condition was set to a high temperature of 30 °C. The experimental results show that thermal sensation votes (TSV) are lower and thermal comfort votes (TCV) are higher in the simulated natural wind environment than in the other two environments. Statistical analysis of subjects’ environmental preferences showed that simulated natural wind was the most preferred option. When exposed to simulated natural wind, subjects reported a stronger sense of softness and relaxation than when exposed to constant mechanical wind or sinusoidal wind. Additionally, the level of calmness experienced under the simulated natural wind condition was found to be lower than that observed under the constant mechanical wind condition. Comparing TSV and TCV results over time reveals that thermal comfort is influenced not only by thermal sensation but also by the stimulation that different types of airflow variation exert on the human body. Concurrently, in airflow environments, thermal sensation exhibits a non-linear relationship with changes in skin temperature, and this relationship may be influenced by airflow stimulation. This study clarifies the mechanism by which different airflows affect thermal comfort differently in high-temperature environments. It thereby provides both experimental evidence and theoretical support for the airflow design of air-conditioning systems, with the goal of aligning such designs with human physiological perceptual characteristics.