Jinghua Jiang

Dr. Jinghua Jiang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
RWRuifeng Wang
Ruifeng Wang
Fenghao WangFenghao Wang
Fenghao Wang
YXYuze Xue
Yuze Xue
JJJinghua Jiang
Jinghua Jiang
YZYuping Zhang
Yuping Zhang
CCChaofan Chen
Chaofan Chen
To contribute to the goal of carbon neutralization, the closed-loop borehole heat exchanger system is widely applied to use geothermal energy for building cooling and heating. In this work, a new type of medium-shallow borehole heat exchanger (MSBHE) is proposed, which is coaxial type and has a depth range between 200 m to 500 m. To investigate the long-term performance of MSBHE in the area with unbalanced cooling and heating load of buildings and the sustainable load imbalance ratio under different design parameters, a comprehensive numerical model is established. The results show that the drilling depth significantly influences the sustainable load imbalance ratio of MSBHE. As the drilling depth is increased from 200 m to 500 m, the load imbalance ratio of the MSBHE increases from 20.76% to 60.29%. In contrast, the load imbalance ratio is always kept at the same level with different inlet velocities and operation modes. Furthermore, in a 9-MSBHE array system, the heat exchanger located in the middle of the array has the lowest load imbalance ratio of 48.97%, which is 15.98% lower than the borehole in the edge location. This is caused by the significant influence of the shifted-load phenomenon among MSBHEs in an array system. The findings of the work imply that this newly proposed MSBHE can sustain a notable load imbalance ratio, which is particularly applicable to the areas with a strong imbalance of annual building load.

14 August 2025 in Buildings
Verified
Journal Article
Open access
PDF file
CLChunfeng Lao
Chunfeng Lao
JLJing Ling
Jing Ling
JLJing Li
Jing Li
JJJinghua Jiang
Jinghua Jiang
Sheng ZhangSheng Zhang
Sheng Zhang
MGMingliang Gu
Mingliang Gu
Dynamic ventilation has proven effective in enhancing indoor thermal comfort. However, previous studies often expose participants to inconsistent thermal environments, potentially compromising the accuracy of subjective evaluations. To address this limitation, this study implemented dynamic ventilation with fluctuating air velocity in an accurately controlled environmental chamber. Objective measurements of indoor air velocity and air temperature distribution are conducted, and subjective thermal sensation votes are collected under thermally consistent environments among participants. During the experiment, all participants experience similar dynamic thermal environments. The results show that participants experience thermal comfort under dynamic ventilation. Dynamic ventilation enhances convective heat transfer between the human body and the surrounding air and stimulates cutaneous cold receptors. The pronounced cooling effect of dynamic airflow contributes to a reduction in skin temperature on the head, chest, upper arm, forearm, hand, and thigh, with a temperature drop ranging from 1.3% to 2.8%. In addition, dynamic ventilation significantly reduces draft risk, with the proportion of participants reporting a dissatisfied sensation decreasing from 10% to 0%. This study demonstrates the advantages of dynamic ventilation in improving thermal comfort and minimizing draft risk under controlled and uniform environmental conditions for all participants.

24 November 2024 in Buildings
Verified
Journal Article
Open access
PDF file
JLJing Li
Jing Li
JLJing Ling
Jing Ling
YWYijin Wang
Yijin Wang
CLChunfeng Lao
Chunfeng Lao
DGDi Gao
Di Gao
Sheng ZhangSheng Zhang
Sheng Zhang
Aim: This study aims to develop supply air jet models for split air conditioners. Background: Designing and operating an air conditioning system based on the unique characteristics of the supply air jet is essential to control the draft risk. Motivation: Due to the distinct differences in air supply characteristics of the split air conditioners caused by the intermittent operation and the complex design of supply air outlets, the existing supply air jet models designed for central air conditioning systems are unsuitable for split air conditioners. Significant results: In this study, models for the trajectory position, velocity, and temperature of the supply air jet for split air conditioners are established based on the Abramovich jet theory and Bayesian Markov Chain Monte Carlo (MCMC) algorithm. The effectiveness of the proposed models is demonstrated via comparison with the training dataset from the experimentally validated Computational Fluid Dynamics simulation of a split air conditioner. For the model testing dataset, the RMSEs of trajectory position, velocity, and temperature are 0.01 m, 0.09 m/s, and 0.09 °C, respectively, with a low supply air velocity and 0.01 m, 0.25 m/s, and 0.03 °C with a high supply air velocity. The proposed models of velocity and temperature of the supply air jet are general for various supply air conditions, while coefficients in the trajectory position model of the supply air jet need to be recalibrated with the proposed Bayesian MCMC algorithm for different supply air conditions. The proposed models provide valuable guidance for the operation of split air conditioners.