Integrated chargers, where the traction inverter is used as the primary charging interface, have emerged as a solution for reducing the cost and footprint of electric vehicle (EV) charging. This article proposes a bidirectional nonisolated integrated charger topology that also provides benefits to motor lifetime and reliability through a reduction in bearing currents and voltages. This is achieved by adding to an EV drive: an $LC$ filter per phase with a common-mode (CM) voltage control; a CM inductor for additional leakage current filtering; contactors to switch between traction and charging modes; and a residual current device to satisfy standards for transformerless charging. To obtain high efficiency and make the filter small for traction applications, variable frequency critical soft switching is leveraged. Traction mode experimental validation demonstrates torque and speed steps with no degradation compared to a standard drive, a decrease in leakage currents and shaft voltages of more than 90%, and an increase in motor drive efficiency of 0.6% at 5-kW output power. Charging mode validation shows active and reactive power steps and peak efficiency of 99.4% and 98.4% at a rated power of 11 kW. Charging mode leakage current is measured to be 22 mA, which satisfies standards permitting the transformerless operation.
13 November 2021 in IEEE Transactions on Power Electronics
A nonisolated DC charger is proposed for electric vehicle (EV) battery system. The leakage current can be reduced by the novel charging system without bulky transformer. A zero sequence voltage control method is developed to stabilize the common-mode voltage, thus, reduce the leakage current. The proposed fast charger includes two energy conversion stages: DC–DC converter for battery side control; DC–AC converter for grid interface and common-mode voltage control. The parameters of the system with the LCL filter are analyzed and optimized for a better performance of grid interface. Grid service functions are designed for the EV charger to provide grid-voltage/frequency compensations. High power (22 kW) and high efficiency ( $>$ 99%) are achieved with low-leakage current ( $<$ 20 mA). The experiments are implemented to verify the proposed EV charger system.
26 July 2022 in IEEE Transactions on Industrial Electronics
This article outlines the design process of a high-efficiency (99.5% peak) transformerless dc electric vehicle fast charger in conjunction with relevant standards on conducted harmonics and leakage current. The topology is a nonisolated transformerless design which allows for the elimination of the additional transformer volume and losses that are present in galvanically isolated topologies. Methods for calculating optimal switching frequency and inductance to minimize loss as a function of chosen switching device and power level are provided. Filter sizing and component values are chosen in conjunction with the previously determined optimal switching frequency and inductance. Heatsink design rationale are then derived. Experimental efficiency, switching waveforms, and output voltage and current quality results are provided. Industrial topology feasibility is shown through experimental adherence to relevant underwriters laboratories (UL), international electrotechnical commission (IEC), institution of engineering and technology (IET), and institute of electrical and electronics engineers (IEEE) standards.
6 April 2022 in IEEE Transactions on Industry Applications
A transformerless electric vehicle (EV) onboard charger is designed for robust grid fault ride-through/trip capabilities and the attenuation of leakage current (99%). The performance under abnormal grid conditions are tested experimentally to verify the ride-through and trip capabilities of the proposed onboard charger in compliance with IEEE Std. 1547. Also, the experiments have validated the low leakage current, stable zero sequence voltage and full range of variable-frequency soft-switching for high efficiency.
27 May 2022 in IEEE Transactions on Power Electronics
A variable-frequency critical-soft-switching (VF-CSS) model predictive control method is developed combining with a modified nonisolated inverter to improve the efficiency. A two-level control structure is developed, including 1) the central-level grid-side inductor current control and zero-sequence voltage control; and 2) the local-level per-phase power module control of VF-CSS model predictive controller with state estimator. Two VF-CSS controllers are proposed, including variable-continuous-frequency critical-soft-switching controller and variable-discrete-frequency critical-soft-switching, to achieve critical soft-switching operation for high efficiency. The combination of MPC and VF-CSS guarantees a complete critical soft-switching operation at full period range of varying frequency and especially during transient. The state estimator provides sampling noise rejection and accurate switch-side inductor current estimations for MPC and VF-CSS. Also, with the help of state estimator, the current sensor cost is reduced by 50%. Meanwhile, the estimator contributes to a more accurate switch-side inductor current reading for MPC implementation with variable continuous frequency controller, especially when the critical soft switching requires huge inductor current ripple. With the proposed control strategies and topology, medium-frequency ( $>$ 200 kHz, 45 $\mu$ H) and high-frequency ( $>$ 1 MHz, 4.5 $\mu$ H) test benches are validated experimentally. The efficiency is above 99% at a rated power of 15 kW. A power density of more than 10.4 kW/L is achieved.
9 November 2023 in IEEE Transactions on Transportation Electrification
A >99.5% efficient grid-tied inverter with peak values of 30kW power, 13.7kW/L volumetric power density, 10.17kW/kg gravimetric power density, and 1.2MHz switching frequency is proposed in this paper. This union of high efficiency and high power density is achieved through a unique combination of technologies and is maximally leveraged through an ηρ optimization. The first is a variable frequency critical soft-switching (VFCSS) scheme that allows the converter to maintain soft-switching over all permissible load conditions. This enables a simultaneous increase of the switching frequency and a decrease of the inductance without penalizing efficiency. The second technology is an additional capacitance placed across the drain-source terminals of each FET. This can allow for over a 40% reduction in turn-off losses at the expense of an increase in the required dead time. The last technology is a simple open-loop duty cycle compensation scheme that effectively mitigates the distortion caused by the combination of high switching frequencies and large dead times. An ηρ optimization process with its associated volume and loss estimations are provided. A brief discussion on the control of the converter is shown followed by a description of the constructed physical prototype. Lastly, experimental results showing efficiency, rated power operation, total harmonic distortion, and transient load steps are provided for a grouping of different grid voltages.