13 November 2021 in IEEE Transactions on Power Electronics
A nonisolated DC charger is proposed for electric vehicle (EV) battery system. The leakage current can be reduced by the novel charging system without bulky transformer. A zero sequence voltage control method is developed to stabilize the common-mode voltage, thus, reduce the leakage current. The proposed fast charger includes two energy conversion stages: DC–DC converter for battery side control; DC–AC converter for grid interface and common-mode voltage control. The parameters of the system with the LCL filter are analyzed and optimized for a better performance of grid interface. Grid service functions are designed for the EV charger to provide grid-voltage/frequency compensations. High power (22 kW) and high efficiency ( $>$ 99%) are achieved with low-leakage current ( $<$ 20 mA). The experiments are implemented to verify the proposed EV charger system.
26 July 2022 in IEEE Transactions on Industrial Electronics
This article outlines the design process of a high-efficiency (99.5% peak) transformerless dc electric vehicle fast charger in conjunction with relevant standards on conducted harmonics and leakage current. The topology is a nonisolated transformerless design which allows for the elimination of the additional transformer volume and losses that are present in galvanically isolated topologies. Methods for calculating optimal switching frequency and inductance to minimize loss as a function of chosen switching device and power level are provided. Filter sizing and component values are chosen in conjunction with the previously determined optimal switching frequency and inductance. Heatsink design rationale are then derived. Experimental efficiency, switching waveforms, and output voltage and current quality results are provided. Industrial topology feasibility is shown through experimental adherence to relevant underwriters laboratories (UL), international electrotechnical commission (IEC), institution of engineering and technology (IET), and institute of electrical and electronics engineers (IEEE) standards.
4 April 2022 in Applied Energy
6 April 2022 in IEEE Transactions on Industry Applications
A transformerless electric vehicle (EV) onboard charger is designed for robust grid fault ride-through/trip capabilities and the attenuation of leakage current (99%). The performance under abnormal grid conditions are tested experimentally to verify the ride-through and trip capabilities of the proposed onboard charger in compliance with IEEE Std. 1547. Also, the experiments have validated the low leakage current, stable zero sequence voltage and full range of variable-frequency soft-switching for high efficiency.
24 June 2021 in IEEE Transactions on Industrial Electronics
Varying the operating frequency helps dual-active bridge topologies increase the system efficiency since the soft-switching is regained at low-load condition. This article proposes a conduction-loss-based variable frequency modulation (VFM) that decouples the phase-shift from the frequency control that conventional VFM applies. The power losses for the shared-bus battery-balancing topology are elaborated as switching frequency varies. The results show that increasing the operating frequency within the reasonable boundaries can benefit not only the switching loss but also the conduction losses. The switching loss is nearly constant, whereas the conduction losses decrease significantly. A factor of output power and transformer current, namely power-per-ampere, is derived as a function of operating conditions and phase-shift independent of switching frequency. The operating setpoints are selected to minimize the factor using both online and offline optimizations. The proposed control strategy outperforms constant frequency modulation by up to 30% below 30% rated power. Furthermore, compared with conventional VFM, the proposed method improves the efficiency of the system under test by 1.5% below 50% normalized power, with significantly less computational resources needed.
26 July 2022 in IEEE Transactions on Industry Applications
A modular model predictive control method for non-isolated three-phase $LCL$ grid-connected converter is proposed with zero-sequence voltage control and regulated third harmonic injection capabilities. The control method is proposed with the combination of a modified three-phase $LCL$ converter topology to stabilize the common mode voltage. The control mechanism consists of two layers: (1) the central level control of $dq$ sequences output current control cascaded with (2) the local level control of zero-sequence voltage, three-phase inductor current/capacitor voltage model predictive control. No grid side inductance value is needed for the two-layer cascaded control structure which both improves the dynamic performance from inner MPC loop and avoids the MPC parametric error caused by the uncertainty of grid side inductance. With the zero-sequence model predictive control, the common mode voltage and leakage current can be attenuated without bulky isolation transformer. A regulated third harmonic injection (RTHI) method is designed based on the zero-sequence voltage control and the proposed modified converter topology to improve the DC bus utilization and avoid the over-modulation issue. Compared with the conventional third harmonic injection methods, no extra harmonics are injected to the grid and there is no need for specialized grid THD optimization algorithm with the proposed zero-sequence controlled RTHI. The stability and robustness of the proposed regulated third harmonic injection method are also improved with the zero-sequence MPC regulation. Also, the modular concept of local MPC module enables the extensibility for the power converter control with a flexible number of phases. The dynamic performance, leakage current attenuation, DC bus utilization and grid-connection power quality of the proposed model predictive control method with RTHI have been validated experimentally.