Said Al-Hallaj

Said Al-Hallaj


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Energy Conversion and Management
Verified
Journal Article
Closed access
AAAhmed Aljehani
Ahmed Aljehani
SRSiddique Ali K. Razack
Siddique Ali K. Razack
LNLudwig Nitsche
Ludwig Nitsche
Said Al-HallajSaid Al-Hallaj
Said Al-Hallaj

1 June 2021 in Applied Energy
Verified
Journal Article
Closed access
AGAnurag Goyal
Anurag Goyal
EKEric Kozubal
Eric Kozubal
JWJason Woods
Jason Woods
MNMalek Nofal
Malek Nofal
Said Al-HallajSaid Al-Hallaj
Said Al-Hallaj

1 January 2020 in Applied Thermal Engineering
Verified
Journal Article
Closed access
AAAhmed Aljehani
Ahmed Aljehani
LNLudwig C. Nitsche
Ludwig C. Nitsche
Said Al-HallajSaid Al-Hallaj
Said Al-Hallaj

21 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
YGYana Galazutdinova
Yana Galazutdinova
RCRuby-Jean Clark
Ruby-Jean Clark
Said Al-HallajSaid Al-Hallaj
Said Al-Hallaj
SKSumanjeet Kaur
Sumanjeet Kaur
Mohammed M. FaridMohammed M. Farid
Mohammed M. Farid
This paper introduces an innovative design for an “inorganic salt-expanded graphite” composite thermochemical system. The storage unit is made of a perforated, compressed, expanded graphite block impregnated with molten CaCl2∙6H2O; the humid air passes through the holes that allow the moisture to diffuse and react with the salt. The prepared block underwent 90 hydration-dehydration cycles. Although most of the performed cycles were carried out with salt overhydration and deliquescence, the treated samples have remained mechanically and thermally stable with no drop in energy density. The volumetric energy density of the composite ranged from 135.5 to 277.6 kWh/m3, depending on airflow rate and absolute humidity. To ensure composite material cycling stability, the energy density of the block was measured during hydration at similar conditions of absolute humidity, inlet temperature, and airflow rate (0.01 kgwater/kgair, 20 °C, 400 l/min). The average energy density at these conditions was sustained at 219 kWh/m3. The block integrity was monitored by visual inspection after removing it from the reactor chamber every few cycles. Both the composite material and its manufacturing process are simple and easy to scale up for future commercialization.

1 January 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
Said Al-HallajSaid Al-Hallaj
Said Al-Hallaj
SKSiddique Khateeb
Siddique Khateeb
AAAhmed Aljehani
Ahmed Aljehani
MPMike Pintar
Mike Pintar
Energy consumption for commercial building cooling accounts for 15% of all commercial building’s electricity usage [1]. Electric utility companies charge their customers time of use consumption charges ($/kWh) and additionally demand usage charges ($/kW) to limit peak energy consumption and offset their high operating costs. Thus, there is an economic incentive to reduce both the electricity consumption charges and demand charges by developing new energy efficient technologies. Thermal energy storage (TES) systems using a phase change material (PCM) is one such technology that can reduce demand charges and shift the demand from on-peak to off-peak rates. Ice and chilled water have been used in thermal storage systems for many decades, but they have certain limitations, which include a phase change temperature of 0 degrees Celsius and relatively low thermal conductivity in comparison to other materials, which limit their applications as a storage medium. To overcome these limitations, a novel phase change composite (PCC) TES material was developed that has much higher thermal conductivity that significantly improves the charge / discharge rate and a customizable phase change temperature to allow for better integration with HVAC systems. Compared to ice storage, the PCC TES system is capable of very high heat transfer rate and has lower system and operational costs. Economic analysis was performed to compare the PCC TES system with ice system and favorable economics was proven. A 4.5 kWh PCC TES prototype system was also designed for testing and validation purpose.