Nicholas Clements

Dr. Nicholas Clements


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2014 in Current Environmental Health Reports
Verified
Journal Article
Open access
PDF file
SASara D. Adar
Sara D. Adar
PFPaola A. Filigrana
Paola A. Filigrana
NCNicholas Clements
Nicholas Clements
JPJennifer Peel
Jennifer Peel
Airborne particles have been linked to increased mortality and morbidity. As most research has focused on fine particles (PM2.5), the health implications of coarse particles (PM10-2.5) are not well understood. We conducted a systematic review and meta-analysis of associations for short- and long-term PM10-2.5 concentrations with mortality and hospital admissions. Using 23 mortality and 10 hospital admissions studies, we documented suggestive evidence of increased morbidity and mortality in relation to higher short-term PM10-2.5 concentrations, with stronger relationships for respiratory than cardiovascular endpoints. Reported associations were highly heterogeneous, however, especially by geographic region and average PM10-2.5 concentrations. Adjustment for PM2.5 and publication bias resulted in weaker and less precise effect estimates, although positive associations remained for short-term PM10-2.5 concentrations. Inconsistent relationships between effect estimates for PM10-2.5 and correlations between PM10-2.5 and PM2.5 concentrations, however, indicate that PM10-2.5 associations cannot be solely explained by co-exposure to PM2.5. While suggestive evidence was found of increased mortality with long-term PM10-2.5 concentrations, these associations were not robust to control for PM2.5. Additional research is required to better understand sources of heterogeneity of associations between PM10-2.5 and adverse health outcomes.

15 June 2016 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
NCNicholas Clements
Nicholas Clements
Michael HanniganMichael Hannigan
Michael Hannigan
SMShelly Miller
Shelly Miller
JPJennifer L. Peel
Jennifer L. Peel
JMJana B. Milford
Jana B. Milford
Coarse (PM10−2.5) and fine (PM2.5) particulate matter in the atmosphere adversely affect human health and influence climate. While PM2.5 is relatively well studied, less is known about the sources and fate of PM10−2.5. The Colorado Coarse Rural-Urban Sources and Health (CCRUSH) study measured PM10−2.5 and PM2.5 mass concentrations, as well as the fraction of semi-volatile material (SVM) in each size regime (SVM2.5, SVM10−2.5), from 2009 to early 2012 in Denver and comparatively rural Greeley, Colorado. Agricultural operations east of Greeley appear to have contributed to the peak PM10−2.5 concentrations there, but concentrations were generally lower in Greeley than in Denver. Traffic-influenced sites in Denver had PM10−2.5 concentrations that averaged from 14.6 to 19.7 µg m−3 and mean PM10−2.5 ∕ PM10 ratios of 0.56 to 0.70, higher than at residential sites in Denver or Greeley. PM10−2.5 concentrations were more temporally variable than PM2.5 concentrations. Concentrations of the two pollutants were not correlated. Spatial correlations of daily averaged PM10−2.5 concentrations ranged from 0.59 to 0.62 for pairs of sites in Denver and from 0.47 to 0.70 between Denver and Greeley. Compared to PM10−2.5, concentrations of PM2.5 were more correlated across sites within Denver and less correlated between Denver and Greeley. PM10−2.5 concentrations were highest during the summer and early fall, while PM2.5 and SVM2.5 concentrations peaked in winter during periodic multi-day inversions. SVM10−2.5 concentrations were low at all sites. Diurnal peaks in PM10−2.5 and PM2.5 concentrations corresponded to morning and afternoon peaks of traffic activity, and were enhanced by boundary layer dynamics. SVM2.5 concentrations peaked around noon on both weekdays and weekends. PM10−2.5 concentrations at sites located near highways generally increased with wind speeds above about 3 m s−1. Little wind speed dependence was observed for the residential sites in Denver and Greeley. The mass concentration data reported here are being used in ongoing epidemiologic studies for PM in northeastern Colorado.

2 April 2018 in Atmosphere
Verified
Journal Article
Open access
PDF file
NCNicholas Clements
Nicholas Clements
PKPatricia Keady
Patricia Keady
JEJoanne B. Emerson
Joanne B. Emerson
NFNoah Fierer
Noah Fierer
SMShelly Miller
Shelly Miller
Aerosol measurements were collected at fifteen homes over the course of one year in Colorado (USA) to understand the temporal variability of indoor air particulate matter and bacterial concentrations and their relationship with home characteristics, inhabitant activities, and outdoor air particulate matter (PM). Indoor and outdoor PM2.5 concentrations averaged (±st. dev.) 8.1 ± 8.1 μg/m3 and 6.8 ± 4.5 μg/m3, respectively. Indoor PM2.5 was statistically significantly higher during summer compared to spring and winter; outdoor PM2.5 was significantly higher for summer compared to spring and fall. The PM2.5 I/O ratio was 1.6 ± 2.4 averaged across all homes and seasons and was not statistically significantly different across the seasons. Average indoor PM10 was 15.4 ± 18.3 μg/m3 and was significantly higher during summer compared to all other seasons. Total suspended particulate bacterial biomass, as determined by qPCR, revealed very little seasonal differences across and within the homes. The qPCR I/O ratio was statistically different across seasons, with the highest I/O ratio in the spring and lowest in the summer. Using one-minute indoor PM10 data and activity logs, it was observed that elevated particulate concentrations commonly occurred when inhabitants were cooking and during periods with elevated outdoor concentrations.

14 January 2013 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
NCNicholas Clements
Nicholas Clements
JMJana B. Milford
Jana B. Milford
SMShelly Miller
Shelly Miller
WNWilliam Navidi
William Navidi
JPJennifer L. Peel
Jennifer L. Peel
Michael HanniganMichael Hannigan
Michael Hannigan
In studies of coarse particulate matter (PM10-2.5), mass concentrations are often estimated through the subtraction of PM2.5 from collocated PM10 tapered element oscillating microbalance (TEOM) measurements. Though all field instruments have yet to be updated, the Filter Dynamic Measurement System (FDMS) was introduced to account for the loss of semivolatile material from heated TEOM filters. To assess errors in PM10-2.5 estimation when using the possible combinations of PM10 and PM2.5 TEOM units with and without FDMS, data from three monitoring sites of the Colorado Coarse Rural–Urban Sources and Health (CCRUSH) study were used to simulate four possible subtraction methods for estimating PM10-2.5 mass concentrations. Assuming all mass is accounted for using collocated TEOMs with FDMS, the three other subtraction methods were assessed for biases in absolute mass concentration, temporal variability, spatial correlation, and homogeneity. Results show collocated units without FDMS closely estimate actual PM10-2.5 mass and spatial characteristics due to the very low semivolatile PM10-2.5 concentrations in Colorado. Estimation using either a PM2.5 or PM10 monitor without FDMS introduced absolute biases of 2.4 µg/m3 (25%) to –2.3 µg/m3 (–24%), respectively. Such errors are directly related to the unmeasured semivolatile mass and alter measures of spatiotemporal variability and homogeneity, all of which have implications for the regulatory and epidemiology communities concerned about PM10-2.5. Two monitoring sites operated by the state of Colorado were considered for inclusion in the CCRUSH acute health effects study, but concentrations were biased due to sampling with an FDMS-equipped PM2.5 TEOM and PM10 TEOM not corrected for semivolatile mass loss. A regression-based model was developed for removing the error in these measurements by estimating the semivolatile concentration of PM2.5 from total PM2.5 concentrations. By estimating nonvolatile PM2.5 concentrations from this relationship, PM10-2.5 was calculated as the difference between nonvolatile PM10 and PM2.5 concentrations. Implications: Errors in the estimation of PM10-2.5 concentrations using subtraction methods were shown to be related to the unmeasured semivolatile mass when using certain combinations of TEOM instruments. For the northeastern Colorado region, the absolute bias associated with this error significantly affects mean and 95th percentile values, which would affect assessment of compliance if PM10-2.5 is regulated in the future. Estimating PM10-2.5 mass concentrations using nonvolatile mass concentrations from collocated PM10 and PM2.5 TEOM monitors closely estimates the total PM10-2.5 mass concentrations. A corrective model that removes the described error was developed and applied to data from two sites in Denver. Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.

7 July 2020 in medRxiv
Verified
Preprint
Open access
PDF file
SMShelly Miller
Shelly Miller
DMDebanjan Mukherjee
Debanjan Mukherjee
JWJoseph Wilson
Joseph Wilson
NCNicholas Clements
Nicholas Clements
CSCedric Steiner
Cedric Steiner
Background: Isolation space must be expanded during pandemics involving airborne transmission. Little to no work has been done to establish optimal design strategies and implementation plans to ease surge capacity and expand isolation capacity over long periods in congregate living facilities. The COVID-19 pandemic has an airborne transmission component and requires isolation, which is difficult to accomplish in skilled nursing facilities. Purpose: In this study we designed, implemented, and validated an isolation space at a skilled nursing facility in Lancaster, PA. The overall goal was to minimize disease transmission between residents and staff within the facility. Basic Procedures: We created an isolation space by modifying an existing HVAC system of the SNF. We measured pressure on-site and performed computational fluid dynamics and Lagrangian particle-based modeling to test containment and possible transmission extent given the isolation space is considered negative rather than individual rooms. Main Findings: Pressure data shows the isolation space maintained an average hourly value of (standard deviation) -2.3 Pa (0.12 Pa) pressure differential between it and the external hallway connected to the rest of the facility. No transmission of SARS-CoV-2 between residents isolated to the space occurred, nor did any transmission to the staff or other residents occur. The isolation space was successfully implemented and, as of writing, continues to be operational through the pandemic. Highlights: Negative pressure isolation space is an effective method to meet needed surge capacity during the COVID-19 pandemic and future pandemics Planning for how and where to rapidly create a negative pressure isolation space is needed in congregate living areas such as skilled nursing facilities This demonstration shows the feasibility of using low-cost and in-house systems to quickly create negative pressure within a skilled nursing facility hallway and to maintain these conditions, minimizing disease transmission between residents and staff