The aim of this study is to show the feasibility of a biventricular implantable cardioverter-defibrillator [cardiac resynchronization therapy (CRT)–ICD] implantation using an electroanatomic navigation system and a low dose of fluoroscopy. Here four case reports of patients affected by dilated cardiomyopathy, who underwent cardiac resynchronization therapy, are described. During 2010, four patients were admitted to our Cardiology Department for implantation of an CRT–ICD device in primary prevention. All had an ejection fraction of <35% and were in New York Heart Association class III despite optimal medical therapy. The implantations were performed using the EnSite NavX system. All the leads were positioned in the cardiac chambers utilizing the three-dimensional navigation system and only using X-ray to check that the leads had been positioned correctly. To our knowledge, these cases are the first use of an electroanatomic system for implantation of an CRT–ICD device and in all four cases the cannulation of the coronary sinus (CS) was performed only using the mapping system. Electroanatomic navigation made it possible to minimize X-ray exposure during the implantation of the CRT–ICD device; in addition, the mapping system was used to choose the optimum position of the CS catheter using as reference the maximum activation delay between the two ventricles. The NavX system shows great potential during the implantation of an CRT–ICD device. It seems to be feasible, safe, and extremely beneficial in terms of a reduction in X-ray exposure. Furthermore, there is benefit of more detailed information and accuracy during the CS lead placement.
4 June 2020 in Journal of Cardiovascular Electrophysiology
Background: Epicardial placement of the left ventricular (LV) lead via a video‐assisted thoracoscopic (VAT) approach is an alternative to the standard transvenous technique.Hypothesis: Long‐term safety and efficacy of VAT and transvenous LV lead implantation are comparable. To test it, we reviewed our experience and we compared the outcomes of patients who underwent implantation with the two techniques.Methods: The VAT procedure is performed under general anesthesia, with oro‐tracheal intubation and right‐sided ventilation, and requires two 5 mm and one 15 mm thoracoscopic ports. After pericardiotomy at the spot of the epicardial target area, pacing measurements are taken and a spiral screw electrode is anchored at the final pacing site. The electrode is then tunneled to the pectoral pocket and connected to the device.Results: 105 patients were referred to our center for epicardial LV lead implantation. After pre‐operative assessment, 5 patients were excluded because of concomitant conditions precluding surgery. The remaining 100 underwent the procedure. LV lead implantation was successful in all patients (median pacing threshold 0.8 ± 0.5 V, no phrenic nerve stimulation) and cardiac resynchronization therapy was established in all but one patient. The median procedure time was 75 min. During a median follow‐up of 24 months, there were no differences in terms of death, cardiovascular hospitalizations or device‐related complications vs the group of 100 patients who had undergone transvenous implantation. Patients of both groups displayed similar improvements in terms of ventricular reverse remodeling and functional status.Conclusions: Our VAT approach proved safe and effective, and is a viable alternative in the case of failed transvenous LV implantation.
Electrical isolation of pulmonary veins (PVI) is the cornerstone of invasive treatment of atrial fibrillation (AF). However, arrhythmia-free survival of a PVI only approach is suboptimal in patients with persistent and long-term persistent AF. Hybrid AF ablation has been developed with the aim of combining the advantages of a thoracoscopic surgical ablation (direct visualization of anatomical structures to be spared and the possibility to perform epicardial lesions) and endocardial ablation (possibility to check line block, confirm PVI, and possibility to perform cavotricuspid isthmus ablation). Patient selection is of utmost importance. In persistent and long-term persistent AF, hybrid AF ablation demonstrated promising results in terms of AF free survival. It has been associated with a relatively low complication rate if performed in centers with expertise in hybrid procedures and experience with both surgical and endocardial ablation. Different techniques have been described, with different approaches and lesion sets. The aim of this review is to provide a state-of-the-art overview of hybrid AF ablation.