Telemonitoring modalities in heart failure (HF) have been proposed as being essential for future organization and transition of HF care, however, efficacy has not been proven. A comprehensive meta-analysis of studies on home telemonitoring systems (hTMS) in HF and the effect on clinical outcomes are provided. A systematic literature search was performed in four bibliographic databases, including randomized trials and observational studies that were published during January 1996–July 2022. A random-effects meta-analysis was carried out comparing hTMS with standard of care. All-cause mortality, first HF hospitalization, and total HF hospitalizations were evaluated as study endpoints. Sixty-five non-invasive hTMS studies and 27 invasive hTMS studies enrolled 36 549 HF patients, with a mean follow-up of 11.5 months. In patients using hTMS compared with standard of care, a significant 16% reduction in all-cause mortality was observed [pooled odds ratio (OR): 0.84, 95% confidence interval (CI): 0.77–0.93, I2: 24%], as well as a significant 19% reduction in first HF hospitalization (OR: 0.81, 95% CI 0.74–0.88, I2: 22%) and a 15% reduction in total HF hospitalizations (pooled incidence rate ratio: 0.85, 95% CI 0.76–0.96, I2: 70%). These results are an advocacy for the use of hTMS in HF patients to reduce all-cause mortality and HF-related hospitalizations. Still, the methods of hTMS remain diverse, so future research should strive to standardize modes of effective hTMS. Summary results for all-cause mortality, first heart failure hospitalization, and total/recurrent heart failure hospitalizations divided in invasive home telemonitoring systems and non-invasive home telemonitoring systems and total. I2 represents heterogeneity between studies. CI, confidence interval.
Wearables offer a promising solution for enhancing remote monitoring (RM) of heart failure (HF) patients by tracking key physiological parameters. Despite their potential, their clinical integration faces challenges due to the lack of rigorous evaluations. This review aims to summarize the current evidence and assess the readiness of wearables for clinical practice using the Medical Device Readiness Level (MDRL). A systematic search identified 99 studies from 3112 found articles, with only eight being randomized controlled trials. Accelerometery was the most used measurement technique. Consumer-grade wearables, repurposed for HF monitoring, dominated the studies with most of them in the feasibility testing stage (MDRL 6). Only two of the described wearables were specifically designed for HF RM, and received FDA approval. Consequently, the actual impact of wearables on HF management remains uncertain due to limited robust evidence, posing a significant barrier to their integration into HF care.
8 February 2024 in European Heart Journal - Digital Health
Aims: Elevated blood pressure (BP) is a key risk factor in cardiovascular diseases. However, obtaining reliable and reproducible BP remains a challenge. This study, therefore, aimed to evaluate a novel cuffless wristband, based on photoplethysmography (PPG), for continuous BP monitoring. Methods and results: Predictions by a PPG-guided algorithm were compared to arterial BP measurements (in the sub-clavian artery), obtained during cardiac catheterization. Eligible patients were included and screened based on AAMI/European Society of Hypertension (ESH)/ISO Universal Standard requirements. The machine learning-based BP algorithm required three cuff-based initialization measurements in combination with ∼100 features (signal-derived and patient demographic-based). Ninety-seven patients and 420 samples were included. Mean age, weight, and height were 67.1 years (SD 11.1), 83.4 kg (SD 16.1), and 174 cm (SD 10), respectively. Systolic BP was ≤100 mmHg in 48 samples (11%) and ≥160 mmHg in 106 samples (25%). Diastolic BP was ≤70 mmHg in 222 samples (53%) and ≥85 mmHg in 99 samples (24%). The algorithm showed mean errors of ±3.7 mmHg (SD 4.4 mmHg) and ±2.5 mmHg (SD 3.7 mmHg) for systolic and diastolic BP, respectively. Similar results were observed across all genders and skin colours (Fitzpatrick I-VI). Conclusion: This study provides initial evidence for the accuracy of a PPG-based BP algorithm in combination with a cuffless wristband across a range of BP distributions. This research complies with the AAMI/ESH/ISO Universal Standard, however, further research is required to evaluate the algorithms performance in light of the remaining European Society of Hypertension recommendations. Clinical trial registration: www.clinicaltrials.gov, NCT05566886.
Timely detection of atrial fibrillation (AF) is crucial for the prevention of serious consequences such as stroke and heart failure, yet it remains challenging due to its often asymptomatic or paroxysmal nature. Wearable devices with artificial intelligence algorithms offer promising solutions. AF detection by the CardioWatch 287-2 (CW2), a wrist-worn photoplethysmography (PPG) and single-lead ECG device, was compared to 24-h Holter. Patient compliance, AF prevalence and AF burden were evaluated for 27 additional days. Data from 150 participants (mean age 64 ± 12 SD; 41% female) were analysed. The CW2’s PPG and single-lead ECG algorithms achieved a specificity ≥98% and sensitivity ≥95% for AF detection, and 99% correlation for AF burden, compared to 24-h Holter. AF prevalence increased from 14.7% (24-h Holter) to 26.7% (28-day CW2). Thus, the wrist-worn device showed promising performance in detecting AF and determining AF burden. The trial was registered on ClinicalTrials.gov (NCT05899959) on June 2, 2023.
In order to study the safety of ‘rescue’ strategies in the treatment of patients with failed thrombolysis, all 548 patients admitted with evolving myocardial infarction to the Thoraxcenter, Rotterdam, from January 1997 until April 1999 were reviewed. Of these patients, 49% had received thrombolysis. Of patients treated with thrombolysis and not referred from other hospitals (n=154) 36% received rescue therapy for failed thrombolysis. Three rescue therapies were used after failed thrombolysis: percutaneous coronary intervention (74%), retreatment with thrombolysis (39%) and platelet glycoprotein (GP) IIb/IIIa receptor blockers (53%), often in combination. Platelet GP IIb/IIIa receptor blockers were administered in 64% of patients treated with rescue percutaneous coronary intervention. Major bleeding occurred in 14% of all thrombolysis treated patients, and in 30% of patients who received multiple rescue therapies. Bleeding was related to heparin usage and platelet GP IIb/IIIa receptor blockers, as was the insertion of catheters for percutaneous coronary intervention or intra-aortic balloon pumps. Major bleeding resulted in one death due to a ruptured ventricle, one haemorrhagic stroke, and three cases of tamponade for which surgery was needed. Four of these patients had received combination rescue therapy. Rescue therapy is a widely used strategy for failed thrombolysis, but is associated with a high bleeding rate. Alternative reperfusion strategies to avoid failed thrombolysis should be considered in high risk patients. Copyright 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.