Makarand Ballal

Dr. Makarand Ballal

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SSShelas Sathyan
Shelas Sathyan
HSHiralal Muralidhar Suryawanshi
Hiralal Muralidhar Suryawanshi
ASAmardeep Balasaheb Shitole
Amardeep Balasaheb Shitole
MBMakarand Sudhakar Ballal
Makarand Sudhakar Ballal
VBVijay B. Borghate
Vijay B. Borghate
An isolated four channel dc/dc converter with zero voltage switching is proposed as the front-end of multiple inverter structures to integrate renewable and other low voltage energy sources to micro grids. The interleaving technique is adopted to connect each module of proposed converter to a common dc source. This dc source can be a fuel cell stack, PV panels, battery, or any other low voltage dc source. All four channels are interleaved and a phase shift of 90° is provided between the gate signals of each channels, which reduces the input current ripple. The output port of the proposed converter provide four isolated and regulated dc voltages. These isolated dc sources can be connected in series or parallel or series-parallel manner to obtain required dc-link voltage of various inverter structure. Issues like capacitor voltage balancing of diode clamped multilevel inverters can overcome through the proposed converter. By incorporating a coupled inductor for isolation and energy storage along with voltage multiplier circuit, the proposed converter can achieve higher voltage step up with lower turns ratio and lower voltage stress at moderate duty ratio. Hence, mosfets of low voltage rating (low R DS (ON)) can be utilized to reduce conduction loss. A 2 kW prototype of the proposed interleaved dc/dc converter is developed and tested with diode clamped three-level inverter, five-level inverter, and three-phase two-level inverter to verify the design.

28 July 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
RDRohit R. Deshmukh
Rohit R. Deshmukh
MBMakarand Ballal
Makarand Ballal
HSHiralal M. Suryawanshi
Hiralal M. Suryawanshi
The dc microgrid consists of renewable energy sources, energy storage system, and loads. The power output of these RESs is intermittent in nature. This raises the problem of power sharing among the sources and bus voltage regulation. This article proposes a new fuzzy logic based control scheme to mitigate power sharing mismatch during the variation in available power of RESs. It exploits the nonlinear mapping between sources power sharing with variation in available power. The novel fuzzy logic controller improves the system bus voltage regulation under different operating conditions. It is simple in design and does not need knowledge about a complex mathematical model of the overall system. The experimental results are presented which shows the superiority of the proposed control under different operating conditions over the conventional control.

28 May 2019 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
RDRohit R. Deshmukh
Rohit R. Deshmukh
MBMakarand Ballal
Makarand Ballal
HSHiralal Murlidhar Suryawanshi
Hiralal Murlidhar Suryawanshi
MMMahesh K. Mishra
Mahesh K. Mishra
This paper proposes a new control algorithm for effective power management in the DC microgrid with renewable energy sources (RES) and energy storage system (ESS). This scheme overcomes average power sharing and bus voltage regulation problems with maximum utilization of source power. In the source, the additional power available beyond its average rated value is treated as virtual generation. The new references are generated considering virtual generation. The novelty of proposed algorithm is to bring the virtual generation effectively in operation. The Virtual generation of individual source is based on available power source. The proposed algorithm reduces the charging/discharging cycles of ESS and hence enhances the life span of ESS. It reduces the stress on interfaced converters, regulates the system bus voltage, reduces power fluctuations on the sources and enhances stability. The proposed control algorithm is verified in MATLAB simulation and in Real Time simulator.

1 August 2017 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
MBMakarand Ballal
Makarand Ballal
GJGajanan C. Jaiswal
Gajanan C. Jaiswal
DTDhananjay R. Tutkane
Dhananjay R. Tutkane
PVPrasad A. Venikar
Prasad A. Venikar
MMMahesh Kumar Mishra
Mahesh Kumar Mishra
HSHiralal M. Suryawanshi
Hiralal M. Suryawanshi
Deregulation in power industry accelerates competition among various power companies. These companies are trying to gain maximum profit with minimum maintenance cost. This could be achieved by developing a condition‐based monitoring product for the assessment of health of substation and service transformers. This study presents online condition monitoring system (OCMS) for transformers which is useful to replace reactive and preventive maintenance of transformers by predictive maintenance. Proposed OCMS is cost effective, online and accurate tool and it has several features like proposing corrective actions for the benefit of power utilities. Proposed system results are evaluated by comparing with the results obtained from utility model. Proposed OCMS applies only to transformers without abnormal faults such as detected by dissolved gas analysis. It is therefore very different from the other health index algorithms present in the market for condition monitoring of transformers, including in case of abnormal faults.

15 March 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
PVPrasad Arvind Venikar
Prasad Arvind Venikar
MBMakarand Ballal
Makarand Ballal
BUBhimrao Sitaram Umre
Bhimrao Sitaram Umre
HSHiralal Murlidhar Suryawanshi
Hiralal Murlidhar Suryawanshi
An online approach based on application of search coil for transformer winding fault detection is presented in this paper. Earlier attempts report use of search coil for the detection of transformer interturn fault. This paper extends application of search coil for detection of winding displacement in addition to interturn fault identification. Experimental results based on specially designed 10-kVA transformer are presented to analyze search coil voltages during healthy and faulty conditions. The algorithm detects phase (U, V , W ), side (LV, HV), and precise location of the fault. Discrimination between interturn fault and winding radial displacement is also achieved by search coil voltage analysis. The results are experimentally verified based on impedance analyzer plots. Experimental analysis indicates that the proposed method is independent of load on the transformer, vector group, nature of winding, balanced or unbalanced source voltage, source voltage harmonics, inrush, and overexcitation conditions.

24 December 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MBMakarand Ballal
Makarand Ballal
MWManish Ganesh Wath
Manish Ganesh Wath
HSHiralal Murlidhar Suryawanshi
Hiralal Murlidhar Suryawanshi
Current transformers (CTs) are extensively used for the measurement of electrical energy, and hence they play a crucial role in the revenue generation for power distribution utilities. The novelty of this paper is that it presents artificial neural network (ANN) application for the ratio and phase angle error corrections of CTs in the presence of harmonic distortions. In this paper, the behaviors of silicon iron alloy and nanocrystalline alloy CTs are examined by the means of a number of experimental tests under the sinusoidal and distorted waveform conditions. The relation between the nature of CTs secondary current waveforms (CTSwf) with their metrological properties, connected burdens, and nature of load currents (linear or nonlinear) is established. The training data are obtained by the nature of CTSwf in terms of amplitude errors, time shifts, and deviations caused by different harmonic contents between input and output quantities. The ANN is trained for various operating conditions. The implementation of the error correction system and data acquisition is done using dSPACE 1104 software. The experimental results illustrate that the proposed technique can be used for error compensation in case of sinusoidal and the distorted waveform composed of fundamental and many harmonics.