Edith  Navarro Antón

Dr. Edith Navarro Antón

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2011 in Sensors
Verified
Journal Article
Open access
PDF file
JMJaime Sánchez Moreno
Jaime Sánchez Moreno
DRDiego Ramírez-Muñoz
Diego Ramírez-Muñoz
Susana Cardoso De FreitasSusana Cardoso De Freitas
Susana Cardoso De Freitas
SBSilvia Casans Berga
Silvia Casans Berga
EAEdith Navarro Antón
Edith Navarro Antón
PFPaulo Freitas*
Paulo Freitas*
A compensation method for the sensitivity drift of a magnetoresistive (MR) Wheatstone bridge current sensor is proposed. The technique was carried out by placing a ruthenium temperature sensor and the MR sensor to be compensated inside a generalized impedance converter circuit (GIC). No internal modification of the sensor bridge arms is required so that the circuit is capable of compensating practical industrial sensors. The method is based on the temperature modulation of the current supplied to the bridge, which improves previous solutions based on constant current compensation. Experimental results are shown using a microfabricated spin-valve MR current sensor. The temperature compensation has been solved in the interval from 0 °C to 70 °C measuring currents from −10 A to +10 A.

1 October 2006 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
DRDiego Ramírez-Muñoz
Diego Ramírez-Muñoz
José Sánchez-MorenoJosé Sánchez-Moreno
José Sánchez-Moreno
SBSilvia Casans Berga
Silvia Casans Berga
EMEnrique Castro Montero
Enrique Castro Montero
Candid ReigCandid Reig
Candid Reig
EAEdith Navarro Antón
Edith Navarro Antón
A compensation method of the sensitivity drift of the Wheatstone bridge sensor is proposed. The technique was carried out by placing a temperature sensor and the bridge to be compensated inside a generalized impedance converter with input reference current. No internal modification of the bridge arms is required so that the circuit is capable to compensate practical industrial sensors. The method is based on the temperature modulation of the current supplied to the bridge, which improves previous solutions based on constant current compensation. Experimental results are shown using a commercial magnetoresistive bridge sensor.

5 August 2022 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
Mohamed SabanMohamed Saban
Mohamed Saban
SCSilvia Casans-Berga
Silvia Casans-Berga
RGRafael Garcia-Gil
Rafael Garcia-Gil
EAEdith Navarro Antón
Edith Navarro Antón
Otman AghzoutOtman Aghzout
Otman Aghzout
Alfredo Rosado-MuñozAlfredo Rosado-Muñoz
Alfredo Rosado-Muñoz
The rapid development of LoRa and LoRaWAN received a wide interest in research in order to understand the performance of this technologies for various IoT applications. In this article, we propose an IoT system for smart buildings based on LoRa and LoRaWAN. The main aim of this system is monitoring the moisture of wood in buildings; specifically, in cultural heritage buildings. Monitoring uses wireless sensor nodes that are digitally controlled and low-power. The wireless sensor node includes a moisture sensor that relies on a novel resistance measurement method which is developed and tested, including a new printed circuit board (PCB). The sensor comprises a LoRa communication module in order to be used as the end-node of the proposed system. To complete the monitoring system, a cloud-based application was developed to provide remote visualization and control for all LoRa sensor nodes in a building. The proposed system is scalable and represents a practical solution for early detection of wood moisture due to heavy rain, leaks, etc. The path loss is evaluated, showing that the proposed LoRa system can be applied for preservation of heritage buildings despite the attenuation of thick walls and complex architectural structures.

1 June 2003 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
SCS. Casans
S. Casans
EAEdith Navarro Antón
Edith Navarro Antón
DRD. Ramı́rez
D. Ramı́rez
ECE. Castro
E. Castro
ABAntonio Baldi
Antonio Baldi
NANatalia Abramova
Natalia Abramova

1 November 2019 in Electronics
Verified
Journal Article
Open access
PDF file
SBSilvia Casans Berga
Silvia Casans Berga
RGRafael Garcia-Gil
Rafael Garcia-Gil
EAEdith Navarro Antón
Edith Navarro Antón
Alfredo Rosado-MuñozAlfredo Rosado-Muñoz
Alfredo Rosado-Muñoz
A novel method for measuring the electrical resistance in wood is presented. It is based on applying an Alternating Current (AC) to two electrodes rammed into the wood. The method reduces the transient time for value stabilization. In case of Direct Current (DC) resistance measurement methods, typically used in wood measurement, an initial transient exists, invalidating the measured value during an initial transient period. This measurement method uses an electronic circuit based on a relaxation oscillator where the wood automatically sets the oscillation frequency depending on its electrical resistance. Compared to other AC methods, this circuit greatly simplifies the measurement process, not requiring any previous analysis for wood AC frequency estimation. Experimental results for four different wood species showed that, in all cases, the transient response of the measured wood resistance is improved when compared to the DC resistance method, reducing the stabilization time from 10–12 min in DC measurements to almost zero for the novel measurement method. The deviation between the initial wood resistance measurement and the stable value resulted in a range between 0.2% and 5% with the proposed method, while a range between 6% and 10% was obtained when using the DC method. Moreover, the proposed circuit is able to detect changes in wood resistance produced by small variations in temperature and environmental relative humidity during continuous long term measurements. For repeatability analysis, it was verified that similar ambient conditions of temperature and relative humidity (variations lower than 1 °C and 1%, respectively) in different moments provided variations lower than 1.5%. The method can also be applied to other fiber materials affectd by polarization effects when an electrical current is applied into them.

3 April 2008 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DRDiego Ramírez-Muñoz
Diego Ramírez-Muñoz
JMJaime Sanchez Moreno
Jaime Sanchez Moreno
Candid ReigCandid Reig
Candid Reig
SBSilvia Casans Berga
Silvia Casans Berga
EAEdith Navarro Antón
Edith Navarro Antón
A generalized impedance converter (GIC) is presented in this paper as a programmable current source. A study of its properties and limitations is shown. Its current efficiency is compared with that of Howland topologies, and it is improved in this paper. The contribution of the operational amplifier static offsets to the current source is obtained by presenting typical values of these parameters, and an equivalent circuit with its differential and common modes is presented. The calculated and experimental GIC input impedances are obtained, showing its bandwidth limitation and proposing the possibility of extending the input impedance frequency response without varying its low-frequency value. In this paper, the GIC is used to provide constant current to a series sensor loop and a magnetoresistive current sensor (Wheatstone bridge), which are located within the GIC itself. In both cases, the GIC works under the DC regime, unlike usual AC use.