Mustafa Erdem Sağsöz

Dr. Mustafa Erdem Sağsöz

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in The Eurasian Journal of Medicine
Verified
Journal Article
Open access
HOHayri Ogul
Hayri Ogul
UBUmmugulsum Bayraktutan
Ummugulsum Bayraktutan
BPBerhan Pirimoglu
Berhan Pirimoglu
ZYZeynep Yuceler
Zeynep Yuceler
MSMustafa Erdem Sağsöz
Mustafa Erdem Sağsöz
YKYesim Kizrak
Yesim Kizrak
The purpose of this article is to provide an up to date review on the spectrum of applications of perfusion computed tomography (CT) in the abdomen. New imaging techniques have been developed with the objective of obtaining a structural and functional analysis of different organs. Recently, perfusion CT has aroused the interest of many researchers who are studying the applicability of imaging modalities in the evaluation of abdominal organs and diseases. Perfusion CT enables fast, non-invasive imaging of the tumor vascular physiology. Moreover, it can act as an in vivo biomarker of tumor-related angiogenesis.

21 January 2025 in Gels
Verified
Journal Article
Open access
PDF file
MSMustafa Erdem Sağsöz
Mustafa Erdem Sağsöz
ÖKÖzlem Korkut
Özlem Korkut
Salvatore GalloSalvatore Gallo
Salvatore Gallo
Tissue-equivalent hydrogel dosimeters represent a class of tools that hold significant promise, particularly in the precise measurement of three-dimensional dose distributions in radiotherapy. Due to their physical properties closely resembling those of human soft tissue, these dosimeters effectively replicate the energy transfer phenomena resulting from radiation interactions, such as atomic ionization and scattering by nuclei or electrons. Consequently, tissue-equivalent dosimeters, characterized by their linear energy transfer properties, have been extensively applied in medical physics, radiation oncology, and nuclear safety. Future advancements focusing on developing more stable, less toxic, normoxic, and cost-effective dosimeters could enable their broader adoption. This review provides a comprehensive overview of the key characteristics that make hydrogel dosimeters tissue-equivalent, highlighting their benefits, limitations, and primary application areas. Additionally, it explores current advancements in polymeric gel technology and discusses future directions aimed at optimizing their performance and accessibility for broader adoption.

1 June 2006 in Materials Letters
Verified
Journal Article
Closed access
MSMustafa Erdem Sağsöz
Mustafa Erdem Sağsöz
MEM. Ertugrul
M. Ertugrul
UCU. Cevik
U. Cevik

1 January 2013 in The Eurasian Journal of Medicine
Verified
Journal Article
Open access
UBUmmugulsum Bayraktutan
Ummugulsum Bayraktutan
MKMecit Kantarci
Mecit Kantarci
NCNaci Ceviz
Naci Ceviz
IYIhsan Yuce
Ihsan Yuce
HOHayri Ogul
Hayri Ogul
IKIdris Kaya
Idris Kaya
Interrupted aortic arch is a rare congenital malformation of the aortic arch defined as a loss of luminal continuity between the ascending and descending portions of the aorta. In a simple interrupted aortic arch, only a ventricular septal defect and patent ductus arteriosus are observed. We present a rare complex form of type A interrupted aorta with an aortopulmonary window, an atrial septal defect, a ventricular septal defect, and a patent ductus arteriosus on multidetector computed tomography (MDCT) imaging.

8 November 2025 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Open access
EÇElif Berna Çalı
Elif Berna Çalı
OKOzlem Korkut
Ozlem Korkut
AGAlaaddin Gundes
Alaaddin Gundes
Salvatore GalloSalvatore Gallo
Salvatore Gallo
MSMustafa Erdem Sağsöz
Mustafa Erdem Sağsöz

1 January 2016 in TURKISH JOURNAL OF MEDICAL SCIENCES
Verified
Journal Article
Closed access
MSMustafa Erdem Sağsöz
Mustafa Erdem Sağsöz
RPRüstem Berhan Pi̇rİmOğlu
Rüstem Berhan Pi̇rİmOğlu
In a computed tomography (CT) examination, scanogram images are used to determine the range of the area to be imaged before scanning. The importance of scanogram image exposure has increased since total examination radiation has decreased due to technological advancements. The purpose of this study was to determine and compare radiation doses delivered to patients while the tube was in anterior-posterior (AP) and posterior-anterior (PA) positions during a CT angiography scanogram. The radiation doses absorbed by the breast tissue of 55 female patients who underwent cardiac dual-source computed tomography (DSCT) angiography were determined using thermoluminescent dosimeters (TLD-100, Harshaw, MA, USA). Four patients were excluded from the study for various reasons. Radiation doses absorbed by the breasts were significantly lower when the tube position was switched during the scanogram. The absorbed doses, calculated from scanogram exposures, were 520 ± 50 μSv for the AP projection and 410 ± 45 μSv for the PA projection. Total skin doses from the DSCT examinations were 18.9 ± 2.3 mSv. We attributed the approximately 20% lower doses to the position of the scanogram tube, which was in the PA position.