Hyeonkyeong Choi

Ms. Hyeonkyeong Choi

Medical Device Engineering and Management, Yonsei University, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in JMIR Human Factors
Verified
Journal Article
Open access
HCHyeonkyeong Choi
Hyeonkyeong Choi
SKSeunghee Kim
Seunghee Kim
WJWON SEUK JANG
WON SEUK JANG
Background: Robotic spine surgery has continued to evolve since its US Food and Drug Administration approval in 2004, with products now including real-time video guidance and navigation during surgery. As the market for robotic surgical devices evolves, it is important to consider usability factors. Objective: The primary objective of this study was to determine the user experience of a surgical-assistive robotic device. The secondary objective was to evaluate workload, usability, the After-Scenario Questionnaire (ASQ), and the System Usability Scale (SUS). In addition, this study compares the workload, usability, and satisfaction survey of the device among different occupational groups using the device. Methods: Doctors (n=15) and nurses (n=15), the intended users of the surgical assistant robot, participated in the usability evaluation. Participants performed essential scenarios for the surgical assistant robot and provided scenario-specific satisfaction (ASQ), workload (NASA Task Load Index), and usability (SUS) scores. Results: Both doctors and nurses had task success rates of 85% or higher for each scenario. ASQ results showed that both doctors and nurses were least satisfied with ease of completing the task of registration (group 1: mean 4.73, SD 1.57 and group 2: mean 4.47, SD 1.8), amount of time it took (group 1: mean 4.47, SD 1.63 and group 2: mean 4.40, SD 2.09), and support information satisfaction (group 1: mean 5.13, SD 1.50 and group 2: mean 5.13, SD 1.89). All participants had low workloads, and the overall Task Load Index score had a P value of .77, which is greater than .05. The SUS results showed that the overall usability mean for doctors was 64.17 (SD 16.52) and the mean for nurses was 61.67 (SD 19.18), with a P value of .84, which is greater than .05, indicating no difference between the 2 groups. Conclusions: In this study, doctors and nurses evaluated the interaction of the device in a simulated environment, the operating room. By evaluating the use experience and usability of the device with real intended users, we can develop a more effective and convenient user interface.

20 December 2024 in Healthcare
Verified
Journal Article
Open access
PDF file
HCHyeonkyeong Choi
Hyeonkyeong Choi
WJWON SEUK JANG
WON SEUK JANG
Background/Objectives: The patient monitoring system is a critical tool commonly used in hospitals, making it essential to assess caregivers’ user requirements and satisfaction with its usability. In intensive care units (ICUs), the usability of these systems is closely linked to the work efficiency of key users, such as nurses, and directly impacts patient safety and treatment outcomes. This study evaluates the usability of patient monitoring systems in intensive care units (ICUs), focusing on user requirements and satisfaction among nurses, the primary users. Usability is directly linked to work efficiency and patient safety, with post-marketing surveillance (PMS) data from overseas, highlighting issues such as unrecognized alarms, leading to worsened patient conditions. Methods: This study involved 22 ICU nurses who had used the system for over a year, assessing usability through testing, satisfaction surveys, the Health-ITUES, and eye-tracking analysis. Results: The results showed a high success rate (94%) and positive satisfaction scores (4.15, SD = 0.88), with a Health-ITUES score of 4.13 (SD = 0.78). Eye tracking revealed that some functions, including alarms, were overlooked or not recognized. Conclusions: Recommendations include improving the interface for alarm messages and recording deletion functions to enhance user satisfaction and patient safety.

Verified
Journal Article
Open access
PDF file
HCHyeonkyeong Choi
Hyeonkyeong Choi
YKYourim Kim
Yourim Kim
WJWON SEUK JANG
WON SEUK JANG
Background/Objectives: This study aimed to enhance the usability of patient monitoring systems by integrating the Early Warning Score (EWS) function and improving user interface elements. The EWS function is expected to enable the early detection of acute deterioration and prompt medical intervention, while the optimized design supports rapid decision-making by nursing staff. Methods: Two formative usability evaluations were conducted to identify user requirements and improve the device design. A simulated usability test involved five ICU medical staff members, followed by a user preference survey with 72 ICU staff members in a real clinical setting. After incorporating feedback, a summative usability test with 23 ICU nurses was performed to evaluate the revised device. Results: Issues related to unfamiliar parameter terminology and alarm message positioning were identified, and the need for the EWS function was emphasized. The summative evaluation showed an increase in task success rate from 86% to 90% and a significant improvement in user satisfaction from 74.85 (SD: 0.88) to 89.55 (SD: 0.75) (p < 0.05). Conclusions: The integration of the EWS function and interface improvements significantly enhanced the usability of patient monitoring system. These advancements are expected to enable rapid detection of patient deterioration and support timely clinical decision-making by ICU staff.

7 April 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
SNSoyeon Noh
Soyeon Noh
HKHyungmin Kim
Hyungmin Kim
HCHyeonkyeong Choi
Hyeonkyeong Choi
WJWON SEUK JANG
WON SEUK JANG
Background/Objectives: Non-invasive hemodynamic monitoring technologies are being developed to support clinical decisions while reducing risks from invasive procedures. Usability evaluation is essential to assess safety and effectiveness before commercial release. This study examined the usability of a novel patch-type ultrasound-based system (CW10) designed for continuous monitoring in perioperative settings. Methods: A summative evaluation was conducted following IEC 62366-1 with 15 anesthesiologists. Potential hazards were identified via the FDA MAUDE database (Code: DQK) to inform test scenarios. Participants were stratified by clinical experience (1–<5, 5–<10, and ≥10 years) to observe potential variations in operation. In a simulated operating room, users performed 9 clinical scenarios (49 tasks). Metrics included task success rates, subjective satisfaction (5-point Likert scale), and the System Usability Scale (SUS). Results: The overall task success rate was 98.2%. No statistically significant differences were observed across groups in performance, subjective ratings, or SUS scores (p > 0.05). The mean SUS score was 78.5, corresponding to a “Good” usability level. While some use errors occurred in tasks like probe orientation, root cause analysis suggested these were likely due to negative transfer from prior device experience rather than interface complexity. Conclusions: The results suggest the system demonstrates acceptable usability and consistent operation across experience levels. Integrated automated features and the patch design may contribute to reducing inter-user variability for continuous monitoring. This study provides usability evidence that may inform the development of similar non-invasive technologies.

4 April 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
HCHyeonkyeong Choi
Hyeonkyeong Choi
WJWON SEUK JANG
WON SEUK JANG
Background/Objectives: Preterm and critically ill neonates in neonatal intensive care units (NICUs) require multiple medical devices, including incubators, radiant warmers, phototherapy systems, and patient monitors. The coexistence of standalone devices without interoperability increases cognitive and operational burdens for healthcare providers and leads to spatial inefficiency. This study aimed to develop and evaluate a multi-functional neonatal incubator integrating these core functions into a single platform, using user-centered design (UCD) and usability engineering principles. Methods: By synthesizing and analyzing international standards (ISO 13485, IEC 62366-1, IEC 62366-2, and ISO 9241-210), a four-phase design process was established. Following the development of the monitoring system, the design was iteratively refined and validated through repeated formative usability evaluations. A summative usability evaluation was then conducted with 20 NICU clinicians in a simulated NICU environment, using 13 scenarios comprising 39 tasks. Outcome measures included task success rate, the After-Scenario Questionnaire (ASQ), the NASA Task Load Index (NASA-TLX), and the System Usability Scale (SUS). Results: The overall task success rate was 95.64%. When analyzed by function, success rates were 94.63% for incubator-related tasks, 98.33% for patient monitoring, 96.67% for radiant warmer tasks, and 98.33% for phototherapy tasks. The mean SUS score was 78.63, exceeding the benchmark score of 68 that indicates good usability. In addition, no statistically significant differences were observed in workload (NASA-TLX) or usability (SUS) scores according to clinical role or length of clinical experience. Conclusions: The multi-functional neonatal incubator developed in this study demonstrated high usability despite the integration of multiple medical device functions. The findings suggest that this integrated system has the potential to enhance clinical workflow efficiency, optimize spatial utilization, and improve patient safety in NICU settings.

27 November 2023 in JMIR Preprints
Verified
Preprint
Open access
HCHyeonkyeong Choi
Hyeonkyeong Choi
SKSeunghee Kim
Seunghee Kim
WJWON SEUK JANG
WON SEUK JANG
BACKGROUND Robotic spine surgery has continued to evolve since its US Food and Drug Administration approval in 2004, with products now including real-time video guidance and navigation during surgery. As the market for robotic surgical devices evolves, it is important to consider usability factors. OBJECTIVE The primary objective of this study was to determine the user experience of a surgical-assistive robotic device. The secondary objective was to evaluate workload, usability, the After-Scenario Questionnaire (ASQ), and the System Usability Scale (SUS). In addition, this study compares the workload, usability, and satisfaction survey of the device among different occupational groups using the device. METHODS Doctors (n=15) and nurses (n=15), the intended users of the surgical assistant robot, participated in the usability evaluation. Participants performed essential scenarios for the surgical assistant robot and provided scenario-specific satisfaction (ASQ), workload (NASA Task Load Index), and usability (SUS) scores. RESULTS Both doctors and nurses had task success rates of 85% or higher for each scenario. ASQ results showed that both doctors and nurses were least satisfied with ease of completing the task of registration (group 1: mean 4.73, SD 1.57 and group 2: mean 4.47, SD 1.8), amount of time it took (group 1: mean 4.47, SD 1.63 and group 2: mean 4.40, SD 2.09), and support information satisfaction (group 1: mean 5.13, SD 1.50 and group 2: mean 5.13, SD 1.89). All participants had low workloads, and the overall Task Load Index score had a P value of .77, which is greater than .05. The SUS results showed that the overall usability mean for doctors was 64.17 (SD 16.52) and the mean for nurses was 61.67 (SD 19.18), with a P value of .84, which is greater than .05, indicating no difference between the 2 groups. CONCLUSIONS In this study, doctors and nurses evaluated the interaction of the device in a simulated environment, the operating room. By evaluating the use experience and usability of the device with real intended users, we can develop a more effective and convenient user interface.