WON SEUK JANG

Prof. WON SEUK JANG

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Healthcare Informatics Research
Verified
Journal Article
Open access
PDF file
BPByung Eun Park
Byung Eun Park
WJWON SEUK JANG
WON SEUK JANG
SYSun K. Yoo
Sun K. Yoo
Park BE, et al. Healthc Inform Res. 2016 Oct;22(4):299-304. https://doi.org/10.4258/hir.2016.22.4.299

29 May 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ISIlseob Song
Ilseob Song
JYJongmin Yoon
Jongmin Yoon
JKJinbum Kang
Jinbum Kang
MKMin Kim
Min Kim
WJWON SEUK JANG
WON SEUK JANG
YYYangmo Yoo
Yangmo Yoo
Noninvasive monitoring of blood flow in the carotid artery is important for evaluating not only cerebrovascular but also cardiovascular diseases. In this paper, a wireless neckband ultrasound Doppler system, in which two 2.5-MHz ultrasonic sensors are utilized for acquiring Doppler signals from both carotid arteries, is presented for continuously evaluating blood flow dynamics. In the developed wireless neckband Doppler system, the acquired Doppler signals are quantized by 14-bit analog-to-digital-converters running at 40 MHz, and pre-processing operations (i.e., demodulation and clutter filtering) are performed in an embedded field programmable gate array chip. Then, these data are transferred to an external smartphone (i.e., Galaxy S7, Samsung Electronics Co., Suwon, Korea) via Bluetooth 2.0. Post-processing (i.e., Fourier transform and image processing) is performed using an embedded application processor in the smartphone. The developed carotid neckband Doppler system was evaluated with phantom and in vivo studies. In a phantom study, the neckband Doppler system showed comparable results with a commercial ultrasound machine in terms of peak systolic velocity and resistive index, i.e., 131.49 ± 3.97 and 0.75 ± 0.02 vs. 131.89 ± 2.06 and 0.74 ± 0.02, respectively. In addition, in the in vivo study, the neckband Doppler system successfully demonstrated its capability to continuously evaluate hemodynamics in both common carotid arteries. These results indicate that the developed wireless neckband Doppler system can be used for continuous monitoring of blood flow dynamics in the common carotid arteries in point-of-care settings.

1 February 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
JKJinbum Kang
Jinbum Kang
WJWON SEUK JANG
WON SEUK JANG
YYYangmo Yoo
Yangmo Yoo
Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles ( N ) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L ), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (−12° to 12°) with L of 1–9, and the results were found to be comparable to those of the UCDI method ( L = N = 9), i.e. ⩽0.24 cm s −1 , for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L = 4). These results indicate that the proposed HUSDI method can improve flow visualization and quantification with a higher frame rate, PRF and flow sensitivity in cardiovascular imaging.

22 November 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HKHyeonjoo Kim
Hyeonjoo Kim
YJYoung Dae Jeon
Young Dae Jeon
KPKi Bong Park
Ki Bong Park
HCHayeong Cha
Hayeong Cha
MKMoo-Sub Kim
Moo-Sub Kim
DYDo-Kun Yoon
Do-Kun Yoon
Orthopaedic surgeons need to correctly identify bone fragments using 2D/3D CT images before trauma surgery. Advances in deep learning technology provide good insights into trauma surgery over manual diagnosis. This study demonstrates the application of the DeepLab v3+ -based deep learning model for the automatic segmentation of fragments of the fractured tibia and fibula from CT images and the results of the evaluation of the performance of the automatic segmentation. The deep learning model, which was trained using over 11 million images, showed good performance with a global accuracy of 98.92%, a weighted intersection over the union of 0.9841, and a mean boundary F1 score of 0.8921. Moreover, deep learning performed 5–8 times faster than the experts’ recognition performed manually, which is comparatively inefficient, with almost the same significance. This study will play an important role in preoperative surgical planning for trauma surgery with convenience and speed.

1 April 2024 in JMIR Human Factors
Verified
Journal Article
Open access
HCHyeonkyeong Choi
Hyeonkyeong Choi
SKSeunghee Kim
Seunghee Kim
WJWON SEUK JANG
WON SEUK JANG
Background: Robotic spine surgery has continued to evolve since its US Food and Drug Administration approval in 2004, with products now including real-time video guidance and navigation during surgery. As the market for robotic surgical devices evolves, it is important to consider usability factors. Objective: The primary objective of this study was to determine the user experience of a surgical-assistive robotic device. The secondary objective was to evaluate workload, usability, the After-Scenario Questionnaire (ASQ), and the System Usability Scale (SUS). In addition, this study compares the workload, usability, and satisfaction survey of the device among different occupational groups using the device. Methods: Doctors (n=15) and nurses (n=15), the intended users of the surgical assistant robot, participated in the usability evaluation. Participants performed essential scenarios for the surgical assistant robot and provided scenario-specific satisfaction (ASQ), workload (NASA Task Load Index), and usability (SUS) scores. Results: Both doctors and nurses had task success rates of 85% or higher for each scenario. ASQ results showed that both doctors and nurses were least satisfied with ease of completing the task of registration (group 1: mean 4.73, SD 1.57 and group 2: mean 4.47, SD 1.8), amount of time it took (group 1: mean 4.47, SD 1.63 and group 2: mean 4.40, SD 2.09), and support information satisfaction (group 1: mean 5.13, SD 1.50 and group 2: mean 5.13, SD 1.89). All participants had low workloads, and the overall Task Load Index score had a P value of .77, which is greater than .05. The SUS results showed that the overall usability mean for doctors was 64.17 (SD 16.52) and the mean for nurses was 61.67 (SD 19.18), with a P value of .84, which is greater than .05, indicating no difference between the 2 groups. Conclusions: In this study, doctors and nurses evaluated the interaction of the device in a simulated environment, the operating room. By evaluating the use experience and usability of the device with real intended users, we can develop a more effective and convenient user interface.

20 December 2024 in Healthcare
Verified
Journal Article
Open access
PDF file
HCHyeonkyeong Choi
Hyeonkyeong Choi
WJWON SEUK JANG
WON SEUK JANG
Background/Objectives: The patient monitoring system is a critical tool commonly used in hospitals, making it essential to assess caregivers’ user requirements and satisfaction with its usability. In intensive care units (ICUs), the usability of these systems is closely linked to the work efficiency of key users, such as nurses, and directly impacts patient safety and treatment outcomes. This study evaluates the usability of patient monitoring systems in intensive care units (ICUs), focusing on user requirements and satisfaction among nurses, the primary users. Usability is directly linked to work efficiency and patient safety, with post-marketing surveillance (PMS) data from overseas, highlighting issues such as unrecognized alarms, leading to worsened patient conditions. Methods: This study involved 22 ICU nurses who had used the system for over a year, assessing usability through testing, satisfaction surveys, the Health-ITUES, and eye-tracking analysis. Results: The results showed a high success rate (94%) and positive satisfaction scores (4.15, SD = 0.88), with a Health-ITUES score of 4.13 (SD = 0.78). Eye tracking revealed that some functions, including alarms, were overlooked or not recognized. Conclusions: Recommendations include improving the interface for alarm messages and recording deletion functions to enhance user satisfaction and patient safety.