Michael Lauxmann

Prof. Dr. Michael Lauxmann

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
BSBenjamin Sackmann
Benjamin Sackmann
PEPeter Eberhard
Peter Eberhard
MLMichael Lauxmann
Michael Lauxmann
Current clinical practice is often unable to identify the causes of conductive hearing loss in the middle ear with sufficient certainty without exploratory surgery. Besides the large uncertainties due to interindividual variances, only partially understood cause–effect principles are a major reason for the hesitant use of objective methods such as wideband tympanometry in diagnosis, despite their high sensitivity to pathological changes. For a better understanding of objective metrics of the middle ear, this study presents a model that can be used to reproduce characteristic changes in metrics of the middle ear by altering local physical model parameters linked to the anatomical causes of a pathology. A finite-element model is, therefore, fitted with an adaptive parameter identification algorithm to results of a temporal bone study with stepwise and systematically prepared pathologies. The fitted model is able to reproduce well the measured quantities reflectance, impedance, umbo and stapes transfer function for normal ears and ears with otosclerosis, malleus fixation, and disarticulation. In addition to a good representation of the characteristic influences of the pathologies in the measured quantities, a clear assignment of identified model parameters and pathologies consistent with previous studies is achieved. The identification results highlight the importance of the local stiffness and damping values in the middle ear for correct mapping of pathological characteristics and address the challenges of limited measurement data and wide parameter ranges from the literature. The great sensitivity of the model with respect to pathologies indicates a high potential for application in model-based diagnosis.

3 February 2025 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
DBD. Burovikhin
D. Burovikhin
MLMichael Lauxmann
Michael Lauxmann
In order to evaluate the performance of different types of middle‐ear prostheses, a model of human ear was developed. The model was created using finite element (FE) method with the ossicles modeled as rigid bodies. First, the middle‐ear FE model was developed and validated using the middle‐ear transfer function measurements available in literature including pathological cases. Then, the inner‐ear FE model was developed and validated using tonotopy, impedance, and relative BM motion level curves from literature. Both models are based on preexisting research with some improvements and were combined into one coupled FE model. The stapes in the coupled FE ear model was replaced with a model of a stapes prosthesis to create a reconstructed ear model that can be used to estimate how different types of stapes protheses perform relative to each other as well as to the natural ear. The influence of the diameter of the prosthesis as well as the influence of the sealing and opening of the gap in the footplate were investigated along with different measures such as maximum basilar membrane displacement, intracochlear pressure, pressure in scala vestibuli, oval and round window volume displacements, and prosthesis displacement. This will help in designing new innovative types of stapes prostheses or any other type of middle‐ear prostheses, as well as to improve the ones that are already available on the market.

1 July 2021 in Hearing Research
Verified
Journal Article
Open access
BWBirthe Warnholtz
Birthe Warnholtz
MSMerlin Schär
Merlin Schär
BSBenjamin Sackmann
Benjamin Sackmann
MLMichael Lauxmann
Michael Lauxmann
MCMichail Chatzimichalis
Michail Chatzimichalis
JSJae Hoon Sim
Jae Hoon Sim
The incudo-malleal joint (IMJ) in the human middle ear is a true diarthrodial joint and it has been known that the flexibility of this joint does not contribute to better middle-ear sound transmission. Previous studies have proposed that a gliding motion between the malleus and the incus at this joint prevents the transmission of large displacements of the malleus to the incus and stapes and thus contributes to the protection of the inner ear as an immediate response against large static pressure changes. However, dynamic behavior of this joint under static pressure changes has not been fully revealed. In this study, effects of the flexibility of the IMJ on middle-ear sound transmission under static pressure difference between the middle-ear cavity and the environment were investigated. Experiments were performed in human cadaveric temporal bones with static pressures in the range of +/- 2 kPa being applied to the ear canal (relative to middle-ear cavity). Vibrational motions of the umbo and the stapes footplate center in response to acoustic stimulation (0.2-8 kHz) were measured using a 3D-Laser Doppler vibrometer for (1) the natural IMJ and (2) the IMJ with experimentally-reduced flexibility. With the natural condition of the IMJ, vibrations of the umbo and the stapes footplate center under static pressure loads were attenuated at low frequencies below the middle-ear resonance frequency as observed in previous studies. After the flexibility of the IMJ was reduced, additional attenuations of vibrational motion were observed for the umbo under positive static pressures in the ear canal (EC) and the stapes footplate center under both positive and negative static EC pressures. The additional attenuation of vibration reached 4~7 dB for the umbo under positive static EC pressures and the stapes footplate center under negative EC pressures, and 7~11 dB for the stapes footplate center under positive EC pressures. The results of this study indicate an adaptive mechanism of the flexible IMJ in the human middle ear to changes of static EC pressure by reducing the attenuation of the middle-ear sound transmission. Such results are expected to be used for diagnosis of the IMJ stiffening and to be applied to design of middle-ear prostheses.

6 October 2022 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
DBDmitrii Burovikhin
Dmitrii Burovikhin
EDErnst Dalhoff
Ernst Dalhoff
AWAndreas Wagner
Andreas Wagner
FSFritz Schneider
Fritz Schneider
MLMichael Lauxmann
Michael Lauxmann
The hearing contact lens® (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator. In order to evaluate and maximize the HCL's performance, a model of the HCL coupled to a middle-ear model was developed using finite element approach. The model was validated step by step starting with the HCL only. To validate the HCL model, vibrational measurements on the HCL were performed using a laser-doppler-vibrometer (LDV). Then, a silicone cap was placed onto the HCL to provide an interface between the HCL and the tympanic membrane of the middle-ear model, and additional LDV measurements on temporal bones were performed to validate the coupled model that was used to evaluate the equivalent sound pressure of the HCL. Moreover, a de-eper insight was gained into the contact between the HCL and tympanic membrane and its effects on the HCL performance. The model can be used to investigate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL and evaluate the feedback behavior.

9 January 2024 in Partial Differential Equations in Applied Mathematics
Verified
Journal Article
Open access
RHReinhard Honegger
Reinhard Honegger
MLMichael Lauxmann
Michael Lauxmann
BPBarbara Priwitzer
Barbara Priwitzer

10 June 2024 in Heliyon
Verified
Journal Article
Open access
MLMichael Lauxmann
Michael Lauxmann
FVFelix Viehl
Felix Viehl
BPBarbara Priwitzer
Barbara Priwitzer
BSBenjamin Sackmann
Benjamin Sackmann
Current noninvasive methods of clinical practice often do not identify the causes of conductive hearing loss due to pathologic changes in the middle ear with sufficient certainty. Wideband acoustic immittance (WAI) measurement is noninvasive, inexpensive and objective. It is very sensitive to pathologic changes in the middle ear and therefore promising for diagnosis. However, evaluation of the data is difficult because of large interindividual variations. Machine learning methods like Convolutional neural networks (CNN) which might be able to deal with this overlaying pattern require a large amount of labeled measurement data for training and validation. This is difficult to provide given the low prevalence of many middle-ear pathologies. Therefore, this study proposes an approach in which the WAI training data of the CNN are simulated with a finite-element ear model and the Monte-Carlo method. With this approach, virtual populations of normal, otosclerotic, and disarticulated ears were generated, consistent with the averaged data of measured populations and well representing the qualitative characteristics of individuals. The CNN trained with the virtual data achieved for otosclerosis an AUC of 91.1 %, a sensitivity of 85.7 %, and a specificity of 85.2 %. For disarticulation, an AUC of 99.5 %, sensitivity of 100 %, and specificity of 93.1 % was achieved. Furthermore, it was estimated that specificity could potentially be increased to about 99 % in both pathological cases if stapes reflex threshold measurements were used to confirm the diagnosis. Thus, the procedures’ performance is comparable to classifiers from other studies trained with real measurement data, and therefore the procedure offers great potential for the diagnosis of rare pathologies or early-stages pathologies. The clinical potential of these preliminary results remains to be evaluated on more measurement data and additional pathologies.