Dmitrii Burovikhin

Mr. Dmitrii Burovikhin


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2022 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
DBDmitrii Burovikhin
Dmitrii Burovikhin
EDErnst Dalhoff
Ernst Dalhoff
AWAndreas Wagner
Andreas Wagner
FSFritz Schneider
Fritz Schneider
MLMichael Lauxmann
Michael Lauxmann
The hearing contact lens® (HCL) is a new type of hearing aid devices. One of its main components is a piezo-electric actuator. In order to evaluate and maximize the HCL's performance, a model of the HCL coupled to a middle-ear model was developed using finite element approach. The model was validated step by step starting with the HCL only. To validate the HCL model, vibrational measurements on the HCL were performed using a laser-doppler-vibrometer (LDV). Then, a silicone cap was placed onto the HCL to provide an interface between the HCL and the tympanic membrane of the middle-ear model, and additional LDV measurements on temporal bones were performed to validate the coupled model that was used to evaluate the equivalent sound pressure of the HCL. Moreover, a de-eper insight was gained into the contact between the HCL and tympanic membrane and its effects on the HCL performance. The model can be used to investigate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL and evaluate the feedback behavior.

18 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
DBDmitrii Burovikhin
Dmitrii Burovikhin
PKPanagiota Kitsopoulos
Panagiota Kitsopoulos
MLMichael Lauxmann
Michael Lauxmann
KGKarl Grosh
Karl Grosh
In this study, a method for determining the optimal location and orientation of an implantable piezoelectric accelerometer on the short process of the incus is presented. The accelerometer is intended to be used as a replacement for an external microphone to enable totally implantable auditory prostheses. The optimal orientation of the sensor and the best attachment point are determined based on two criteria—maximum pressure sensitivity sum and minimum loudness level sum. The best location is determined to be near the incudomalleolar joint. We find that the angular orientation of the sensor is critical and provide guidelines on that orientation. The method described in this paper can be used to further optimize the design and performance of the accelerometer.

1 December 2024 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
DBDmitrii Burovikhin
Dmitrii Burovikhin
PKPanagiota Kitsopoulos
Panagiota Kitsopoulos
MLMichael Lauxmann
Michael Lauxmann
KGKarl Grosh
Karl Grosh
In this study a method for determining the best placement and optimal orientation of the implantable piezoelectric accelerometer attached to the short process of the incus is developed. The accelerometer is intended to be used as a replacement for an external microphone to enable totally implantable cochlea implants or as part of a totally implantable hearing aid. The best location is determined to be near the incudomalleolar joint. The optimal orientation of the sensor at the determined location is obtained using two criteria - maximum voltage sum and minimum loudness level sum. The method described in the paper can be used to further optimize the design and the performance of the accelerometer.

1 October 2021 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
DBDmitrii Burovikhin
Dmitrii Burovikhin
MLMichael Lauxmann
Michael Lauxmann
EDErnst Dalhoff
Ernst Dalhoff
Hearing contact lens (HCL) is a new type of hearing aid devices. One of its main components is a piezoelectric actuator (PEA). In order to evaluate and maximize the HCL’s performance, a model of the HCL coupled to the middle ear was developed using finite element (FE) approach. To validate the model, vibrational measurements on the HCL and temporal bones were performed using a Laser-Doppler-Vibrometer (LDV). The model was validated step by step starting with HCL only. Then a silicone cap was fitted onto the HCL to provide an interface between the HCL and the tympanic membrane. The HCL was placed on the tympanic membrane and additional measurements were performed to validate the coupled model. The model was used to evaluate the sensitivity of geometrical and material parameters with respect to performance measures of the HCL. Moreover, deeper insight was gained into the feedback behavior, which causes whistling sounds, and the contact between the HCL and tympanic membrane.

1 January 2016
Verified
Book Chapter
Closed access
PDF file
RSRolf Steinbuch
Rolf Steinbuch
AFAndreas Fasold-Schmid
Andreas Fasold-Schmid
SGSimon Gekeler
Simon Gekeler
DBDmitrii Burovikhin
Dmitrii Burovikhin

28 June 2019
Verified
Book Chapter
Closed access
PDF file
DBDmitrii Burovikhin
Dmitrii Burovikhin
BSBenjamin Sackmann
Benjamin Sackmann
MSMerlin Schär
Merlin Schär
JSJ. H. Sim
J. H. Sim
PEP. Eberhard
P. Eberhard
MLM. Lauxmann
M. Lauxmann