Mohammed Alshammari

Mr. Mohammed Alshammari


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2024 in Photonics
Verified
Journal Article
Open access
PDF file
YUFEI CHUYUFEI CHU
YUFEI CHU
MAMohammed Alshammari
Mohammed Alshammari
XWXiaoli Wang
Xiaoli Wang
MHMing Han
Ming Han
With the introduction of advanced Fiber Bragg Grating (FBG) technology, Fabry–Pérot (FP) interferometers have become widely used in fiber-optic ultrasound detection. In these applications, the slope of the reflectance is a critical factor influencing detection results. Due to the intensity limitations of the laser source in fiber-optic ultrasound detection, the reflectance of the FBG is generally increased to enhance the signal-to-noise ratio (SNR). However, increasing reflectance can cause the reflectance curve to deviate from a sinusoidal shape, which in turn affects the slope of the reflectance and introduces greater errors. This paper first investigates the relationship between the transmission curve of the FP interferometer and reflectance, with a focus on the errors introduced by simplified assumptions. Further research shows that in sensors with asymmetric reflectance slopes, their transmittance curves deviate significantly from sinusoidal signals. This discrepancy highlights the importance of achieving symmetrical slopes to ensure consistent and accurate detection. To address this issue, this paper proposes an innovative method to adjust the rear-end reflectance of the FP interferometer by combining stress modulation, UV adhesive, and a high-reflectivity metal disk. Additionally, by adjusting the rear-end reflectance to ensure that the transmittance curve approximates a sinusoidal signal, the symmetry of the slope is maintained. Finally, through practical ultrasound testing, by adjusting the incident wavelength to the positions of slope extrema (or zero) at equal intervals, the expected ultrasound signals at extrema (or zero) can be detected. This method converts the problem of approximating a sinusoidal signal into a problem of the slope adjustment of the transmittance curve, making it easier and more direct to determine its impact on detection results. The proposed method not only improves the performance of fiber-optic ultrasound sensors but also reduces costs, paving the way for broader applications in medical diagnostics and structural health monitoring.

4 August 2025 in Applied Optics
Verified
Journal Article
Closed access
PDF file
BMBabak Moeinimaleki
Babak Moeinimaleki
XWXiaoli Wang
Xiaoli Wang
MAMohammed Alshammari
Mohammed Alshammari
MSMusaddeque Syed
Musaddeque Syed
ACAyush Chinmay
Ayush Chinmay
MHMing Han
Ming Han
Current demodulation methods for fiber Bragg grating (FBG) peaks and Fabry–Perot (FP) extremums rely either on mathematical approaches or on physical models tailored to a single sensing mechanism. As a result, they inherently fail to distinguish reciprocal errors arising from spectral crosstalk between FBG and FP signals in cascaded FBG-FP sensor systems. The asymmetric influence of FP fringe slopes on the FBG peak position, as well as FBG side-lobes effect on FP peak or dip distortion, can introduce errors in identifying the wavelength positions of FBG peaks and FP fringes. In this work, we developed a model to analyze spectral errors in cascaded FBG–FP sensors and validated it through both analytical and experimental approaches. For the analytical method, the errors in FBG peak were calculated within one free spectral range (FSR) of the FP fringe shift for two representative FP configurations, considering influences of the FBG bandwidth and its peak reflectivity. The errors in FP peaks, on the other hand, were extracted as a function of their relative spectral position to the main FBG lobe. For experimental validation, a 10 mm apodized FBG cascaded with a 100 µm thick silicon pillar at the fiber tip was employed to investigate the spectral errors in FBG and FP peaks as predicted by the model. The proposed approach offers a practical framework for characterizing spectral distortions in such systems, enabling accurate parameter measurements and facilitating high-resolution sensing performance.

13 November 2024 in Photonics
Verified
Journal Article
Open access
PDF file
MAMohammed Alshammari
Mohammed Alshammari
MHMing Han
Ming Han
Implementation of edge-filter detection for interrogating optical interferometric ultrasonic sensors is often hindered by the lack of cost-effective laser sources with agile wavelength tunability and good noise performance. The detected signal can also be affected by optical power variations and locking-point drift, negatively affecting the sensor accuracy. Here, we report the use of laser single-sideband generation with a dual-parallel Mach–Zehnder interferometer (DP-MZI) for laser wavelength tuning and locking in edge-filter detection of fiber-optic ultrasonic sensors. We also demonstrate real-time in situ calibration of the sensor response to ultrasound-induced wavelength shift tuning. The DP-MZI is employed to generate a known wavelength modulation of the laser, whose response is used to gauge the sensor response to the ultrasound-induced wavelength shifts in real time and in situ. Experiments were performed on a fiber-optic ultrasonic sensor based on a high-finesse Fabry–Perot interferometer formed by two fiber Bragg gratings. The results demonstrated the effectiveness of the laser locking against laser wavelength drift and temperature variations and the effectiveness of the calibration method against optical power variations and locking-point drift. These techniques can enhance the operational robustness and increase the measurement accuracy of optical ultrasonic sensors.

1 September 2026 in Review of Scientific Instruments
Verified
Journal Article
Closed access
XWXiaoli Wang
Xiaoli Wang
BMBabak Moeinimaleki
Babak Moeinimaleki
MAMohammed Alshammari
Mohammed Alshammari
QSQiwen Sheng
Qiwen Sheng
MSMusaddeque Syed
Musaddeque Syed
MHMing Han
Ming Han
Accurate measurement of transient radiation power is critical for plasma diagnostics in magnetic confinement fusion, where rapid radiation events require high temporal resolution and reliable signal reconstruction. Fiber-optic bolometers (FOBs) based on silicon Fabry–Perot interferometry are attractive alternatives to resistive bolometers because of their compact size, electromagnetic-interference immunity, remote sensing capability, and compatibility with high-temperature and high-vacuum environments. However, conventional FOB designs can exhibit slow and non-first-order thermal responses because of sensing-head thermal capacitance and distributed heat transport in the protruding silica fiber stub, often requiring deconvolution to recover transient radiation profiles. Here, we demonstrate a miniaturized FOB fabricated by femtosecond laser micromachining, featuring a ∼20 μm-diameter silicon pillar and a ∼150 μm-diameter gold absorber disk. The reduced absorber and pillar dimensions decrease sensing-head thermal capacitance, while a flush fiber–copper-holder configuration eliminates the protruding fiber stub and suppresses distributed fiber thermal modes. Compared with previously reported FOBs, the device reduces the cooling time constant from ∼200 to ∼27.5 ms in vacuum while preserving a responsivity of ∼7.8 mK/(W/m2) and a noise-equivalent power density of ∼0.28 W/m2. The thermal response is experimentally shown to be well approximated by a first-order lumped model, enabling direct reconstruction of incident power density using the bolometer equation. Square-wave and millisecond-scale Gaussian radiation transients reconstructed without deconvolution show close agreement with independently measured reference signals, demonstrating ∼1 ms temporal resolution for real-time radiation diagnostics in fusion plasmas.

11 March 2026 in Photonics
Verified
Journal Article
Open access
PDF file
YUFEI CHUYUFEI CHU
YUFEI CHU
XWXiaoli Wang
Xiaoli Wang
MAMohammed Alshammari
Mohammed Alshammari
ZLZi Li
Zi Li
MHMing Han
Ming Han
A robust and cost-effective fiber-optic ultrasound sensor based on a slope-symmetric Fabry–Perot interferometer (FPI) is presented, employing dual-channel quadrature-biased heterodyne interrogation with an acousto-optic modulator (AOM). By introducing a 200 MHz frequency shift that yields an effective π/2 phase offset between the direct (unshifted) and frequency-shifted optical paths, the system ensures complementary sensitivity: when one channel operates at zero slope on the FPI transfer function (minimum sensitivity), the other resides at maximum slope, providing inherent immunity to laser wavelength drift and environmental perturbations. Experimental validation demonstrates reliable ultrasound detection across varying operating points. At quadrature extremes, one channel achieves peak amplitudes of ±2 V while the other is quiescent, whereas intermediate points enable simultaneous detection with amplitudes of ±1.5 V (AOM channel) and ±0.05–0.1 V (direct channel), accompanied by corresponding DC levels ranging from ~0.4 V to 1.6 V. The AOM channel utilizes simple envelope detection after 9.5–11.5 MHz bandpass filtering, maintaining low cost, though coherent mixing is suggested for enhanced weak-signal performance. The angle-symmetric FPI design, combined with gold-disk reflector adaptations and potential femtosecond laser micromachining, further reduces fabrication costs without sacrificing finesse or sensitivity. This quadrature-biased approach offers superior stability compared to single-channel systems, making it highly suitable for practical applications in photoacoustic imaging, nondestructive testing, and structural health monitoring.