A Savitzky-Golay (SG) filter, widely used in signal processing applications, is a finite-impulse-response low-pass filter obtained by a local polynomial regression on noisy observations in the least-squares sense. The problem addressed in this paper is one of optimal order (or filter length) selection of SG filter in the presence of non-Gaussian noise, such that the mean-squared-error (or risk) between the underlying clean signal and the SG filter estimate is minimized. Since mean-squared-error (MSE) depends on the unknown clean signal, direct minimization is impractical. We circumvent the problem within a risk-estimation framework, wherein, instead of minimizing the original MSE, an unbiased estimate of the MSE (which depends only on the noisy observations and noise statistics) is minimized in order to obtain the optimal order. The proposed method gives an unbiased estimate of the MSE considering SG filtering in the presence of additive noise following any distribution with finite first- and second-order statistics and independent of the signal. The SG filter's order and length are optimized by minimizing the unbiased estimate of MSE. The denoising performance of the optimal SG filter is demonstrated on real-world electrocardiogram (ECG) signals as well as signals from the WaveLab Toolbox under Gaussian, Laplacian, and Uniform noise conditions. The proposed denoising algorithm is superior to four benchmark algorithms in low-to-medium input signal-to-noise ratio (SNR) regions ($-5$ dB to 12.5 dB) in terms of the SNR gain.
The accurate detection of heartbeats is of paramount importance in the current healthcare scenario as they act as an indicator for various underlying cardiac conditions and provides an indication of cardiorespiratory fitness. The article presents a novel multimodal data fusion technique using the discrete wavelet transform (DWT) and an application for fusing electrocardiogram (ECG), and photoplethysmogram (PPG) signals to improve beat detection accuracy in ambulatory monitoring using Internet of Things (IoT) sensors. The characteristics of interest from the input signals are first isolated in the wavelet domain and then combined to form a fused feature signal using a weighted average. The weights used are derived from a signal quality index calculation algorithm, suitable for periodic/quasiperiodic signals of different wave morphologies. The peak detection process to identify the heartbeat locations is carried out on the final fused signal. The research evaluates the algorithm performance when different types of noises at varying amplitudes corrupt the ECG and PPG signal inputs, affecting the signal-to-noise ratios (SNRs). The algorithm consistently exhibited a sensitivity of 99.69%, positive predictive value (PPV) of 99.64%, mean beat-to-beat interval relative error of 0.01, and an error spread (corresponding to 90th percentile of relative errors) of 0.02 in the −30 to 50 dB SNR range for all noise scenarios considered. The proposed algorithm exhibits improved detection sensitivities and PPVs under ambulatory conditions compared to state-of-the-art beat detection algorithms and can be used to accurately detect heartbeats where single-channel monitoring tends to fail in IoT devices.
9 December 2021 in IEEE Transactions on Biomedical Circuits and Systems
With advances in circuit design and sensing technology, the acquisition of data from a large number of Internet of Things (IoT) sensors simultaneously to enable more accurate inferences has become mainstream. In this work, we propose a novel convolutional neural network (CNN) model for the fusion of multimodal and multiresolution data obtained from several sensors. The proposed model enables the fusion of multiresolution sensor data, without having to resort to padding/ resampling to correct for frequency resolution differences even when carrying out temporal inferences like high-resolution event detection. The performance of the proposed model is evaluated for sleep apnea event detection, by fusing three different sensor signals obtained from UCD St. Vincent University Hospital’s sleep apnea database. The proposed model is generalizable and this is demonstrated by incremental performance improvements, proportional to the number of sensors used for fusion. A selective dropout technique is used to prevent overfitting of the model to any specific high-resolution input, and increase the robustness of fusion to signal corruption from any sensor source. A fusion model with electrocardiogram (ECG), Peripheral oxygen saturation signal (SpO2), and abdominal movement signal achieved an accuracy of 99.72% and a sensitivity of 98.98%. Energy per classification of the proposed fusion model was estimated to be approximately 5.61 $\mu$J for on-chip implementation. The feasibility of pruning to reduce the complexity of the fusion models was also studied.
This paper presents a comparison of several artificial intelligence (AI) based binary classifiers for detecting the integrity of data obtained from Internet of Things (IoT) enabled wearable sensors. Detecting the integrity of data at the network edge facilitates the elimination of corrupted or unusable data, which translates to a lower amount of data stored and transmitted. This reduces the storage and power requirements of IoT devices without a reduction in functionality. In this work, we explore several machine learning-based classifiers to check the integrity of electrocardiogram (ECG) data. The feature vectors are derived from low complexity kurtosis and skewness based Signal Quality Indices (SQIs). From the experiments, it is found that a bagged ensemble of 3 neural networks achieves the highest detection accuracy of 99.47%. We also estimated the complexity and power consumed by the various classifier implementations and classifier fusion implementations. The energy consumed by the ensemble classifier was estimated to be around 0.039 nJ.