Barry Cardiff

Dr. Barry Cardiff

School of Electrical, Electronic & Communications Engineering, University College Dublin, Dublin, Ireland

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
GSGawsalyan Sivapalan
Gawsalyan Sivapalan
KNKoushik Kumar Nundy
Koushik Kumar Nundy
SDSoumyabrata Dev
Soumyabrata Dev
BCBarry Cardiff
Barry Cardiff
DJDeepu John
Deepu John
In this paper, we propose a lightweight neural network for real-time electrocardiogram (ECG) anomaly detection and system level power reduction of wearable Internet of Things (IoT) Edge sensors. The proposed network utilizes a novel hybrid architecture consisting of Long Short Term Memory (LSTM) cells and Multi-Layer Perceptrons (MLP). The LSTM block takes a sequence of coefficients representing the morphology of ECG beats while the MLP input layer is fed with features derived from instantaneous heart rate. Simultaneous training of the blocks pushes the overall network to learn distinct features complementing each other for making decisions. The network was evaluated in terms of accuracy, computational complexity, and power consumption using data from the MIT-BIH arrhythmia database. To address the class imbalance in the dataset, we augmented the dataset using SMOTE algorithm for network training. The network achieved an average classification accuracy of 97% across several records in the database. Further, the network was mapped to a fixed point model, retrained in a bit accurate fixed-point environment to compensate for the quantization error, and ported to an ARM Cortex M4 based embedded platform. In laboratory testing, the overall system was successfully demonstrated, and a significant saving of $\simeq \!\! 50\%$ power was achieved by gating the wireless transmission using the classifier. Wireless transmission was enabled only to transmit the beats deemed anomalous by the classifier. The proposed technique compares favourably with current methods in terms of computational complexity and has the advantage of stand-alone operation in the edge node, without the need for always-on wireless connectivity making it ideal for IoT wearable devices.

29 June 2021 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
AJArlene John
Arlene John
SRStephen Redmond
Stephen Redmond
BCBarry Cardiff
Barry Cardiff
DJDeepu John
Deepu John
The accurate detection of heartbeats is of paramount importance in the current healthcare scenario as they act as an indicator for various underlying cardiac conditions and provides an indication of cardiorespiratory fitness. The article presents a novel multimodal data fusion technique using the discrete wavelet transform (DWT) and an application for fusing electrocardiogram (ECG), and photoplethysmogram (PPG) signals to improve beat detection accuracy in ambulatory monitoring using Internet of Things (IoT) sensors. The characteristics of interest from the input signals are first isolated in the wavelet domain and then combined to form a fused feature signal using a weighted average. The weights used are derived from a signal quality index calculation algorithm, suitable for periodic/quasiperiodic signals of different wave morphologies. The peak detection process to identify the heartbeat locations is carried out on the final fused signal. The research evaluates the algorithm performance when different types of noises at varying amplitudes corrupt the ECG and PPG signal inputs, affecting the signal-to-noise ratios (SNRs). The algorithm consistently exhibited a sensitivity of 99.69%, positive predictive value (PPV) of 99.64%, mean beat-to-beat interval relative error of 0.01, and an error spread (corresponding to 90th percentile of relative errors) of 0.02 in the −30 to 50 dB SNR range for all noise scenarios considered. The proposed algorithm exhibits improved detection sensitivities and PPVs under ambulatory conditions compared to state-of-the-art beat detection algorithms and can be used to accurately detect heartbeats where single-channel monitoring tends to fail in IoT devices.

29 May 2019 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
ASArmia Salib
Armia Salib
MFMark F. Flanagan
Mark F. Flanagan
BCBarry Cardiff
Barry Cardiff
This paper presents an all-digital background calibration technique for the time skew mismatch in time-interleaved ADCs (TIADCs). The technique jointly estimates all of the time skew values by processing the outputs of a bank of correlators. A low-complexity sampling sequence intervention technique, suitable for successive approximation register (SAR) ADC architectures, is proposed to overcome the limitations associated with blind estimation. A two-stage digital correction mechanism based on the Taylor series is proposed to satisfy the target high-precision correction. A quantitative study is performed regarding the requirements imposed on the digital correction circuit in order to satisfy the target performance and yield, and a corresponding filter design method is proposed, which is tailored to meet these requirements. Mitchell's logarithmic multiplier is adopted for the implementation of the principal multipliers in both the estimation and correction mechanisms, leading to a 25% area and power reduction in the estimation circuit. The proposed calibration is synthesized using a TSMC 28-nm HPL process targeting a 2.4-GHz sampling frequency for an eight-sub-ADC system. The calibration block occupies 0.03 mm² and consumes 11 mW. The algorithm maintains the SNDR above 65 dB for a sinusoidal input within the target bandwidth.

9 December 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
AJArlene John
Arlene John
KNKoushik Kumar Nundy
Koushik Kumar Nundy
BCBarry Cardiff
Barry Cardiff
DJDeepu John
Deepu John
With advances in circuit design and sensing technology, the acquisition of data from a large number of Internet of Things (IoT) sensors simultaneously to enable more accurate inferences has become mainstream. In this work, we propose a novel convolutional neural network (CNN) model for the fusion of multimodal and multiresolution data obtained from several sensors. The proposed model enables the fusion of multiresolution sensor data, without having to resort to padding/ resampling to correct for frequency resolution differences even when carrying out temporal inferences like high-resolution event detection. The performance of the proposed model is evaluated for sleep apnea event detection, by fusing three different sensor signals obtained from UCD St. Vincent University Hospital’s sleep apnea database. The proposed model is generalizable and this is demonstrated by incremental performance improvements, proportional to the number of sensors used for fusion. A selective dropout technique is used to prevent overfitting of the model to any specific high-resolution input, and increase the robustness of fusion to signal corruption from any sensor source. A fusion model with electrocardiogram (ECG), Peripheral oxygen saturation signal (SpO2), and abdominal movement signal achieved an accuracy of 99.72% and a sensitivity of 98.98%. Energy per classification of the proposed fusion model was estimated to be approximately 5.61 $\mu$J for on-chip implementation. The feasibility of pruning to reduce the complexity of the fusion models was also studied.

17 December 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
MSMaryam Saeed
Maryam Saeed
QWQingyuan Wang
Qingyuan Wang
OMOlev Martens
Olev Martens
BLBenoit Larras
Benoit Larras
AFAntoine Frappé
Antoine Frappé
DJDeepu John
Deepu John
In this paper, a new methodology for choosing design parameters of level-crossing analog-to-digital converters (LC-ADCs) is presented that improves sampling accuracy and reduces the data stream rate. Using the MIT-BIH Arrhythmia dataset, several LC-ADC models are designed, simulated and then evaluated in terms of compression and signal-to-distortion ratio. A new one-dimensional convolutional neural network (1D-CNN) based classifier is presented. The 1D-CNN is used to evaluate the event-driven data from several LC-ADC models. With uniformly sampled data, the 1D-CNN has 99.49%, 92.4% and 94.78% overall accuracy, sensitivity and specificity, respectively. In comparison, a 7-bit LC-ADC with 2385 Hz clock frequency and 6-bit clock resolution offers 99.2%, 89.98% and 91.64% overall accuracy, sensitivity and specificity, respectively. It also offers 3x data compression while maintaining a signal-to-distortion ratio of 21.19 dB. Furthermore, it only requires 49% floating-point operations per second (FLOPS) for cardiac arrhythmia classification in comparison with the uniformly sampled ADC. Finally, an open-source event-driven arrhythmia database is presented.

22 March 2023 in IEEE Internet of Things Journal
Verified
Journal Article
Open access
GSGawsalyan Sivapalan
Gawsalyan Sivapalan
KNKoushik Kumar Nundy
Koushik Kumar Nundy
AJAlex P James
Alex P James
BCBarry Cardiff
Barry Cardiff
DJDeepu John
Deepu John
Electrocardiogram (ECG) analysis is widely used in the diagnosis of cardiovascular diseases. This paper proposes an explainable rule-mining strategy for prioritizing abnormal class detection in ECG data. The proposed method utilizes a biased-trained Artificial Neural Network (ANN) with input features derived from an ECG beat sequence and formulates a set of rules at each node of an on-demand tree-like search algorithm. The rule base at each node is derived from a linear combination of the most impactful features identified using gradient analysis in an ANN. The final derived model is an explainable rule-based system that detects abnormal heartbeats based on statistical and morphological features from ECG. The model achieves the target sensitivity, and accuracy with a low run-time complexity through a comprehensive offline rule mining process and is trained using the MIT-BIH Arrhythmia Database. The system achieves an accuracy of 93% with only nine nodes and a test sensitivity of 90% and 80% respectively for VEB and SVEB beat types, when tested on previously unseen ECG data from the INCART database. The model performance and complexity can be easily adjusted based on the real-time resource constraints of a wearable sensor. The model was deployed on an ARM Cortex M4-based embedded device and is shown to achieve a >50% reduction in sensor power consumption when only abnormal beats are wirelessly transmitted. i.e RF transmission is gated using the model output and transmission is disabled when the subject’s ECG is normal. The proposed technique is highly suited for healthcare applications because of its explainability, lower complexity, and real-time flexibility when deployed in the Internet of Things (IoT) enabled wearable edge sensors.