The energy required for the heating and cooling of buildings is strongly dependant on the thermal properties of the construction material. Cement mortar is a common construction material that is widely used in buildings. The main aim of this study is to assess the thermal properties of cement mortar in terms of its thermal conductivity, heat capacity and thermal diffusivity in a wide range of grades (cement: sand ratio between 1:2 and 1:8). As there is insufficient information to predict the thermal conductivity and diffusivity of a cement mortar from its physical and mechanical properties, the relationships between thermal conductivity and diffusivity and density, compressive strength, water absorption and porosity are also discussed. Our results indicate that, for a cement mortar with a 28-day compressive strength in the range of 6–60 MPa, thermal conductivity, specific heat and thermal diffusivity are in the range of 1.5–2.7 W/(m.K), 0.87–1.04 kJ/kg.K and 0.89–1.26 (x10-6 m2/s), respectively. The scanning electron microscope (SEM) images showed that pore size varied from 18 μm to 946 μm for samples with different cement-to-sand ratios. The porosity of cement mortar has a significant effect on its thermal and physical properties. For this reason, thermal conductivity and thermal diffusivity was greater in cement mortar samples with a higher density and compressive strength.
Purpose: The purpose of this paper is to review the concept of occupant behavior and its relation with indoor environmental quality (IEQ) and building energy consumption. The behavior is referred to any direct or indirect action, which is selected by an occupant to manage the unpleasant indoor environmental conditions. Thermal comfort, indoor air quality, aural comfort and visual comfort are the key factors of IEQ evaluation. Human behavior significantly interacts with energy consumption in buildings. Design/methodology/approach: Each IEQ parameter was reviewed separately and the overall IEQ acceptance was considered. In addition, this paper reviews the methods that were used to measure and simulate the IEQ factors, energy consumption and human behavior. Finally, the lack of knowledge in this field is based on the review demonstrated. Findings: Most studies considered one or two IEQ factors to evaluate IEQ acceptance in buildings. Further, weakness of simulating all IEQ factors at the same time is the deficiency of IEQ simulation, based on reviews. In the case of occupant behavior simulation, the uncertainly of human psychological parameter is a drawback to predict behavior. Originality/value: Energy consumption, occupant health and productivity are related to IEQ. Human behavior affects building energy consumption directly. Simulation software and methods can predict IEQ factors and human behavior. Therefore, reviewing the existing studies is critical to find new methods for measuring and simulating IEQ, energy consumption and human behavior in buildings.
The quality of the indoor environment has become a vital component for buildings due to the time spent indoors. To this extent, the performance of the indoor environment is considered as part of the greenery criteria by green rating schemes such as the Green Building Index in Malaysia. This study aims to investigate and assess the quality of the indoor environment of Platinum-certified office buildings in a tropical climate. This research applied a case study approach over two Platinum-certified office buildings. Post-occupancy evaluation is employed integrating full-scale measurement with an occupants’ survey. The measurement was carried out from May to August, and 112 questionnaires were retrieved to evaluate occupants’ satisfaction with aspects of the indoor environment. Thermal comfort, indoor air quality, acoustic, lighting, furniture, and cleanliness are considered as the main study variables. The findings of full-scale measurement indicated high relative humidity, and low air velocity and illuminance. While occupants reported overall indoor environment quality (IEQ) comfort, a significant correlation of variables was observed. The main sources of dissatisfaction were identified as overcooling around 24 °C, high relative humidity (RH), around 70% RH, glare, and background noise around 51.9 dB. Statistically, a significant difference between occupants’ responses to IEQ of two cases was identified, although both buildings are labelled with a Platinum certificate.
Energy consumption to cool an indoor environment is a substantial part of total energy end-use, particularly in a tropical climate with high energy demand for cooling. To improve energy efficiency, cooling systems can be optimized using a variety of neutral indoor temperatures to maintain a balance between an occupant’s thermal comfort and cooling energy demand. This explanatory study investigated the thermal quality and cooling energy demand of a Platinum-certified office building in the tropical climate of Malaysia. The investigation aimed to suggest a balance between occupant thermal comfort and cooling energy demand. The thermal investigation includes an objective field measurement that implements environmental equipment to monitor thermal quality and a subjective occupant’s thermal feedback using a questionnaire survey. To calculate cooling energy demand, the total equivalent temperature difference method (TETD) is applied. The results suggested an occupant’s cooling sensation of around 24 °C, with no significant difference concerning age and gender. Cooling load calculation indicated a 36% energy reduction by increasing air temperature to 26 °C, for occupants to feel thermally comfortable in a tropical climate. These findings contribute to improving sustainable energy policies, sustainable construction, and thermal comfort improvement for a tropical climate.