Masoud Esfandiari

Masoud Esfandiari

Faculty of Built Environment, University of Malaya, Kuala Lumpur 50603, Malaysia
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
MEMasoud Esfandiari
Masoud Esfandiari
SZSuzaini Zaid
Suzaini Zaid
MIMUHAMMAD AZZAM ISMAIL
MUHAMMAD AZZAM ISMAIL
MHMohammad Reza Hafezi
Mohammad Reza Hafezi
Iman AsadiIman Asadi
Iman Asadi
AAArdalan Aflaki
Ardalan Aflaki
The quality of the indoor environment has become a vital component for buildings due to the time spent indoors. To this extent, the performance of the indoor environment is considered as part of the greenery criteria by green rating schemes such as the Green Building Index in Malaysia. This study aims to investigate and assess the quality of the indoor environment of Platinum-certified office buildings in a tropical climate. This research applied a case study approach over two Platinum-certified office buildings. Post-occupancy evaluation is employed integrating full-scale measurement with an occupants’ survey. The measurement was carried out from May to August, and 112 questionnaires were retrieved to evaluate occupants’ satisfaction with aspects of the indoor environment. Thermal comfort, indoor air quality, acoustic, lighting, furniture, and cleanliness are considered as the main study variables. The findings of full-scale measurement indicated high relative humidity, and low air velocity and illuminance. While occupants reported overall indoor environment quality (IEQ) comfort, a significant correlation of variables was observed. The main sources of dissatisfaction were identified as overcooling around 24 °C, high relative humidity (RH), around 70% RH, glare, and background noise around 51.9 dB. Statistically, a significant difference between occupants’ responses to IEQ of two cases was identified, although both buildings are labelled with a Platinum certificate.

1 January 2019 in Building and Environment
Verified
Journal Article
Closed access
AAArdalan Aflaki
Ardalan Aflaki
KHKamran Hirbodi
Kamran Hirbodi
NMNorhayati Mahyuddin
Norhayati Mahyuddin
MYMahmood Yaghoubi
Mahmood Yaghoubi
MEMasoud Esfandiari
Masoud Esfandiari

1 January 2021 in Construction and Building Materials
Verified
Journal Article
Closed access
IAIman Asadi
Iman Asadi
PSPayam Shafigh
Payam Shafigh
MHMohammad Hashemi
Mohammad Hashemi
AAAmir Reza Akhiani
Amir Reza Akhiani
MMMehdi Maghfouri
Mehdi Maghfouri
HMHendrik Simon Cornelis Metselaar
Hendrik Simon Cornelis Metselaar

17 November 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
AAArdalan Aflaki
Ardalan Aflaki
MEMasoud Esfandiari
Masoud Esfandiari
Saleh MohammadiSaleh Mohammadi
Saleh Mohammadi
Natural ventilation has been used widely in buildings to deliver a healthy and comfortable indoor environment for occupants. It also reduces the consumption of energy in the built environment and dilutes the concentration of carbon dioxide. Various methods and techniques have been used to evaluate and predict indoor airspeed and patterns in buildings. However, few studies have been implemented to investigate the relevant methods and tools for the evaluation of ventilation performance in indoor and outdoor spaces. The current study aims to review available methods, identifying reliable ones to apply in future research. This study investigates scientific databases and compares the advantages and drawbacks of methods including analytical models, empirical models, zonal models, and CFD models. The findings indicated the computational fluid dynamics (CFD) model is the most relevant method because of cost-effectiveness, informative technique, and proficiency to predict air velocity patterns and ratios in buildings. Finally, widely used CFD codes and tools are compared considering previous studies. It is concluded the application of codes for research is subject to the complexity and characteristics of a studied model, the area and field of study, the desired turbulence model, and the user interface.

29 December 2017 in Journal of Design and Built Environment
Verified
Journal Article
Open access
PDF file
MEMasoud Esfandiari
Masoud Esfandiari
SZSuzaini Zaid
Suzaini Zaid
MIMUHAMMAD AZZAM ISMAIL
MUHAMMAD AZZAM ISMAIL
The relation between indoor environmental quality (IEQ) and occupants comfort has become a critical area of research through building life cycle. The importance of the relationship becomes highlighted when IEQ has a strong influence to change people behaviour through its nature specifically in places like an office building where the productivity of occupants remains at the top of everything. In this regard, this manuscript documented the parameters of the indoor environment quality which has a strong influence on occupants’ comfort. Through critical review of literature, it has been found that IEQ parameters as thermal, noise, light and air quality could strongly affect the human comfort and health while having a critical role in energy consumption in the building. Moreover, there is a complicated relation among IEQ parameters which make it difficult for a designer to find a balance among them regarding occupants’ comfort and productivity and this complication is more confusing in green construction. Many post occupancy evaluation (POE) studies in both conventional and green buildings have carried out, but almost none of them indicated a full satisfaction with IEQ parameters simultaneously. Therefore, this paper investigated among IEQ parameters and their correlation with each other pertaining to occupants’ satisfaction, health and productivity in office buildings with different methods of construction.

10 November 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
MEMasoud Esfandiari
Masoud Esfandiari
SZSuzaini Zaid
Suzaini Zaid
MIMUHAMMAD AZZAM ISMAIL
MUHAMMAD AZZAM ISMAIL
MHMohammad Reza Hafezi
Mohammad Reza Hafezi
Iman AsadiIman Asadi
Iman Asadi
Saleh MohammadiSaleh Mohammadi
Saleh Mohammadi
Energy consumption to cool an indoor environment is a substantial part of total energy end-use, particularly in a tropical climate with high energy demand for cooling. To improve energy efficiency, cooling systems can be optimized using a variety of neutral indoor temperatures to maintain a balance between an occupant’s thermal comfort and cooling energy demand. This explanatory study investigated the thermal quality and cooling energy demand of a Platinum-certified office building in the tropical climate of Malaysia. The investigation aimed to suggest a balance between occupant thermal comfort and cooling energy demand. The thermal investigation includes an objective field measurement that implements environmental equipment to monitor thermal quality and a subjective occupant’s thermal feedback using a questionnaire survey. To calculate cooling energy demand, the total equivalent temperature difference method (TETD) is applied. The results suggested an occupant’s cooling sensation of around 24 °C, with no significant difference concerning age and gender. Cooling load calculation indicated a 36% energy reduction by increasing air temperature to 26 °C, for occupants to feel thermally comfortable in a tropical climate. These findings contribute to improving sustainable energy policies, sustainable construction, and thermal comfort improvement for a tropical climate.