Objective: Research about the impact of acute stress on inhibitory control remains a contentious topic, with no consensus reached thus far. This study aims to investigate the effects of acute stress on an individual’s inhibitory control abilities and to elucidate the underlying neural mechanisms by analyzing resting state electroencephalogram (EEG) data. Methods: We recruited 32 male college students through participant recruitment information to undergo within-subject experiments under stress and non-stress conditions. Physiological indicators (cortisol and heart rate), self-report questionnaires, and behavioral data from the Stroop task were collected before, during, and after the experiment. Additionally, a five-minute eyes closed resting state EEG data collection was conducted during the Stroop task before. Results: (1) Acute stress led to a reduction in the conflict effect during the participants’ Stroop task in individuals. (2) Stress resulted in an increase in the power of the beta in the resting state EEG. (3) Acute stress caused an increase in the duration of class D and an increase in the transition probabilities from classes C and B to class D in the microstates of the resting state EEG. (4) Acute stress leads to an increase in beta power values in individuals’ resting state EEGs, which is significantly negatively correlated with the reduction of the conflict effect in the Stroop task under stress. Conclusions: Acute stress can enhance individuals’ attentional level, thereby promoting inhibitory control performance.
To investigate the impact of electrode structure on Electrical Stimulation Therapy (EST) for chronic wound healing, this study designed three variants of flexible microelectrodes (FMs) with Ag-Cu coverings (ACCs), each exhibiting distinct geometrical configurations: hexagonal, cross-shaped, and serpentine. These were integrated with PPY/PDA/PANI (3/6) (full name: polypyrrole/polydopamine/polyaniline 3/6). Hydrogel dressing comprehensive animal studies, coupled with detailed electrical and mechanical modeling and simulations, were conducted to assess their performance. Results indicated that the serpentine-shaped FM outperformed its counterparts in terms of flexibility and safety, exhibiting minimal thermal effects and a reduced risk of burns. Notably, FMs with metal coverings under 3% demonstrated promising potential for optoelectronic self-powering capabilities. Additionally, simulation data highlighted the significant influence of hydrogel non-uniformity on the distribution of electrical properties across the skin surface, providing critical insights for optimizing EST protocols when employing hydrogel dressings.