Claudia Coronel-Aguilera

Dr. Claudia Coronel-Aguilera

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2022 in Foods
Verified
Journal Article
Open access
PDF file
CCChuYan Chen Chen
ChuYan Chen Chen
CCClaudia Coronel-Aguilera
Claudia Coronel-Aguilera
BABruce M. Applegate
Bruce M. Applegate
AGAndrew Gehring
Andrew Gehring
Arun K BhuniaArun K Bhunia
Arun K Bhunia
GPGeorge C Paoli
George C Paoli
The USDA-FSIS has zero tolerance for E. coli O157:H7 in raw ground beef. Currently, FSIS collects samples from beef processing facilities and ships them overnight to regional testing laboratories. Pathogen detection requires robust methods that employ an initial 15–24 h culture enrichment. This study assessed the potential of using the ΦV10nluc phage-based luminescence detection assay during enrichment while the sample is in transit. Parameters including phage concentrations, temperature, and media-to-sample ratios were evaluated. Results in liquid media showed that 1.73× 103 pfu/mL of ΦV10nluc was able to detect 2 CFU in 10 h. The detection of E. coli O157:H7 was further evaluated in kinetic studies using ratios of 1:3, 1:2, and 1:1 ground beef sample to enrichment media, yielding positive results for as little as 2–3 CFU in 325 g ground beef in about 15 h at 37 °C. These results suggest that this approach is feasible, allowing the detection of a presumptive positive upon arrival of the sample to the testing lab. As the current cargo hold controlled temperature is required to be 15–25 °C, the need for elevated temperature should be easily addressed. If successful, this approach could be expanded to other pathogens and foods.

13 February 2025 in Foods
Verified
Journal Article
Open access
PDF file
MOMichael F. Oats
Michael F. Oats
CCClaudia Coronel-Aguilera
Claudia Coronel-Aguilera
Bruce M ApplegateBruce M Applegate
Bruce M Applegate
LCLaszlo N. Csonka
Laszlo N. Csonka
Arun K BhuniaArun K Bhunia
Arun K Bhunia
GPGeorge C Paoli
George C Paoli
ΦV10 is an Escherichia coli O157:H7-specific bacteriophage that has been used to develop luminescent reporter assays for the detection of this important foodborne pathogen. Previous work demonstrated the specificity of ΦV10 for infection of E.coli O157:H7 through interaction with the O157 antigen. In addition, modification of the lipopolysaccharide (LPS) via O-acetylation prevents ΦV10 infection in an E. coli O157:H7 expressing a phage-encoded O-acetylase gene. Through assays for phage binding, plaque formation, and lysogeny using non-O157:H7 and O157: non-H7 strains, as well as complementation of an O157:H− strain, it is demonstrated in this study that both the somatic O157 antigen and flagellar H7 antigen are required for productive infection of E. coli O157:H7 by ΦV10. Together, the results indicate that the O157 antigen is required for phage binding and that the H7 antigen is necessary to complete the infection process.